This article addresses the objective, experimental design and methodology of the tests conducted for battery State of Health (SOH) estimation using an accelerated test method. For this purpose, 25 unused cylindrical cells were aged, by continual electrical cycling using a 0.5C charge and 1C discharge to 5 different SOH breakpoints (80, 85, 90, 95 and 100%).
View Article and Find Full Text PDFMegtec Systems pilot-plant scale continuous convective coater. The data was generated as part of an experimental design involving the following coating-drying process variables and ranges: comma bar gap, 80-140 µm; web speed, 0.5-1.