Meningiomas are the most common primary intracranial tumors and can be associated with significant morbidity and mortality. Radiologists, neurosurgeons, neuro-oncologists, and radiation oncologists rely on brain MRI for diagnosis, treatment planning, and longitudinal treatment monitoring. However, automated, objective, and quantitative tools for non-invasive assessment of meningiomas on multi-sequence MR images are not available.
View Article and Find Full Text PDFMeningiomas are the most common primary intracranial tumor in adults and can be associated with significant morbidity and mortality. Radiologists, neurosurgeons, neuro-oncologists, and radiation oncologists rely on multiparametric MRI (mpMRI) for diagnosis, treatment planning, and longitudinal treatment monitoring; yet automated, objective, and quantitative tools for non-invasive assessment of meningiomas on mpMRI are lacking. The BraTS meningioma 2023 challenge will provide a community standard and benchmark for state-of-the-art automated intracranial meningioma segmentation models based on the largest expert annotated multilabel meningioma mpMRI dataset to date.
View Article and Find Full Text PDFThe translation of AI-generated brain metastases (BM) segmentation into clinical practice relies heavily on diverse, high-quality annotated medical imaging datasets. The BraTS-METS 2023 challenge has gained momentum for testing and benchmarking algorithms using rigorously annotated internationally compiled real-world datasets. This study presents the results of the segmentation challenge and characterizes the challenging cases that impacted the performance of the winning algorithms.
View Article and Find Full Text PDFBackground: Moderately hypofractionated radiotherapy (MHRT) is an accepted treatment for localized prostate cancer; however, limited MHRT data address high-risk prostate cancer (HRPC) and/or African American patients. We report clinical outcomes and toxicity profiles for individuals with HRPC treated in an equal access system.
Methods: We identified patients with HRPC treated with MHRT at a US Department of Veterans Affairs referral center.
Purpose: We sought to develop a computer-aided detection (CAD) system that optimally augments human performance, excelling especially at identifying small inconspicuous brain metastases (BMs), by training a convolutional neural network on a unique magnetic resonance imaging (MRI) data set containing subtle BMs that were not detected prospectively during routine clinical care.
Methods And Materials: Patients receiving stereotactic radiosurgery (SRS) for BMs at our institution from 2016 to 2018 without prior brain-directed therapy or small cell histology were eligible. For patients who underwent 2 consecutive courses of SRS, treatment planning MRIs from their initial course were reviewed for radiographic evidence of an emerging metastasis at the same location as metastases treated in their second SRS course.
Purpose: To evaluate the effect of prostate volume on outcomes after moderately hypofractionated radiation therapy (mHFRT) for prostate cancer.
Methods And Materials: Prostate cancer patients treated with mHFRT at a Veteran's Affairs Medical Center from August 20, 2008, to January 31, 2018, were identified. Patients were placed into a large prostate planning target volume (LPTV) cohort if their prostate PTV was in the highest quartile.
Purpose: Data comparing moderately hypofractionated intensity modulated radiation therapy (IMRT) and proton beam therapy (PBT) are lacking. We aim to compare late toxicity profiles of patients with early-stage prostate cancer treated with moderately hypofractionated PBT and IMRT.
Methods And Materials: This multi-institutional analysis included patients with low- or intermediate-risk biopsy-proven prostate adenocarcinoma from 7 tertiary referral centers treated from 1998 to 2018.
The purpose of this study was to investigate whether, compared with traditional criteria, the modified Response Evaluation Criteria in Solid Tumors version 1.1 for immune-based therapeutics (iRECIST) improves prediction of local tumor control and survival in patients with hepatocellular carcinoma (HCC) treated with stereotactic body radiotherapy (SBRT). Fifty-one HCC lesions (mean size, 3.
View Article and Find Full Text PDFPurpose: This guideline systematically reviews the evidence for treatment of pancreatic cancer with radiation in the adjuvant, neoadjuvant, definitive, and palliative settings and provides recommendations on indications and technical considerations.
Methods And Materials: The American Society for Radiation Oncology convened a task force to address 7 key questions focused on radiation therapy, including dose fractionation and treatment volumes, simulation and treatment planning, and prevention of radiation-associated toxicities. Recommendations were based on a systematic literature review and created using a predefined consensus-building methodology and system for grading evidence quality and recommendation strength.
Hepatocellular carcinoma (HCC) is increasing in incidence and mortality. Although the prognosis remains poor, long-term survival has improved from 3% in 1970 to an 18% 5-year survival rate today. This is likely because of the introduction of well tolerated, oral antiviral therapies for hepatitis C.
View Article and Find Full Text PDFPurpose: Bolus-tracked multiphasic contrast computed tomography (CT) is often used in diagnostic radiology to enhance the visibility of pancreas tumors, but is uncommon in radiation therapy pancreas CT simulation, and its impact on gross tumor volume (GTV) delineation is unknown. This study evaluates the lesion conspicuity and consistency of pancreas stereotactic body radiation therapy (SBRT) GTVs contoured in the different contrast phases of triphasic CT simulation scans.
Methods And Materials: Triphasic, bolus-tracked planning CT simulation scans of 10 consecutive pancreas SBRT patients were acquired, yielding images of the pancreas during the late arterial (LA), portal venous (PV), and either the early arterial or delayed phase.
Purpose: Matrix inversion tomosynthesis (MITS) uses linear systems theory and knowledge of the imaging geometry to remove tomographic blur that is present in conventional backprojection tomosynthesis reconstructions, leaving in-plane detail rendered clearly. The use of partial-pixel interpolation during the backprojection process introduces imprecision in the MITS modeling of tomographic blur, and creates low-contrast artifacts in some MITS planes. This paper examines the use of MITS slabs, created by averaging several adjacent MITS planes, as a method for suppressing partial-pixel artifacts.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
January 2011
Purpose: Breath-hold (BH) treatment minimizes internal target volumes (ITV) when treating sites prone to motion. Digital tomosynthesis (DTS) imaging has advantages over cone-beam CT (CBCT) for BH imaging: BH-DTS scan can be completed during a single breath-hold, whereas BH-CBCT is usually acquired by parsing the gantry rotation into multiple BH segments. This study evaluates the localization accuracy of DTS for BH treatment of liver tumors.
View Article and Find Full Text PDFMatrix inversion tomosynthesis (MITS) uses known imaging geometry and linear systems theory to deterministically separate in-plane detail from residual tomographic blur in a set of conventional tomosynthesis ("shift-and-add") planes. A previous investigation explored the effect of scan angle (ANG), number of projections (N), and number of reconstructed planes (NP) on the MITS impulse response and modulation transfer function characteristics, and concluded that ANG = 20 degrees, N = 71, and NP = 69 is the optimal MITS imaging technique for chest imaging on our prototype tomosynthesis system. This article examines the effect of ANG, N, and NP on the MITS exposure-normalized noise power spectra (ENNPS) and seeks to confirm that the imaging parameters selected previously by an analysis of the MITS impulse response also yield reasonable stochastic properties in MITS reconstructed planes.
View Article and Find Full Text PDFPurpose: To evaluate digital tomosynthesis (DTS) technology for daily positioning of patients receiving accelerated partial breast irradiation (APBI) and to compare the positioning accuracy of DTS to three-dimensional cone-beam computed tomography (CBCT).
Methods And Materials: Ten patients who underwent APBI were scanned daily with on-board CBCT. A subset of the CBCT projections was used to reconstruct a stack of DTS image slices.
Purpose: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT).
Methods And Materials: A total of 92 image sessions from 9 prostate cancer patients were analyzed.
The purpose of this study is to propose four-dimensional digital tomosynthesis (4D-DTS) for on-board analysis of motion information in three dimensions. Images of a dynamic motion phantom were reconstructed using acquisition scan angles ranging from 20 degrees (DTS) to full 360 degrees cone-beam computed tomography (CBCT). Projection images were acquired using an on-board imager mounted on a clinical linear accelerator.
View Article and Find Full Text PDFWe developed a novel digital tomosynthesis (DTS) reconstruction method using a deformation field map to optimally estimate volumetric information in DTS images. The deformation field map is solved by using prior information, a deformation model, and new projection data. Patients' previous cone-beam CT (CBCT) or planning CT data are used as the prior information, and the new patient volume to be reconstructed is considered as a deformation of the prior patient volume.
View Article and Find Full Text PDFThe authors report interim clinical results from an ongoing NIH-sponsored trial to evaluate digital chest tomosynthesis for improving detectability of small lung nodules. Twenty-one patients undergoing computed tomography (CT) to follow up lung nodules were consented and enrolled to receive an additional digital PA chest radiograph and digital tomosynthesis exam. Tomosynthesis was performed with a commercial CsI/a-Si flat-panel detector and a custom-built tube mover.
View Article and Find Full Text PDFDigital tomosynthesis (DTS) is a method to reconstruct pseudo three-dimensional (3D) volume images from two-dimensional x-ray projections acquired over limited scan angles. Compared with cone-beam computed tomography, which is frequently used for 3D image guided radiation therapy, DTS requires less imaging time and dose. Successful implementation of DTS for fast target localization requires the reconstruction process to be accomplished within tight clinical time constraints (usually within 2 min).
View Article and Find Full Text PDFDigital tomosynthesis is a technique that generates an arbitrary number of section images of a patient from a single pass of the x-ray tube. It is under investigation for application to a number of clinical detection tasks, and has recently been implemented in commercial devices for chest radiography. Tomosynthesis provides improved visibility of structures in the chest, such as pulmonary nodules, airways, and spine.
View Article and Find Full Text PDFThe authors developed a hybrid multiresolution rigid-body registration technique to automatically register reference digital tomosynthesis (DTS) images with on-board DTS images to guide patient positioning in radiation therapy. This hybrid registration technique uses a faster but less accurate static method to achieve an initial registration, followed by a slower but more accurate adaptive method to fine tune the registration. A multiresolution scheme is employed in the registration to further improve the registration accuracy, robustness, and efficiency.
View Article and Find Full Text PDFThe successful implementation of digital tomosynthesis (DTS) for on-board image guided radiation therapy (IGRT) requires fast DTS image reconstruction. Both target and reference DTS image sets are required to support an image registration application for IGRT. Target images are usually DTS image sets reconstructed from on-board projections, which can be accomplished quickly using the conventional filtered backprojection algorithm.
View Article and Find Full Text PDF