Publications by authors named "Dermot O'Rourke"

This work focuses on the growth patterns of the human fourth lumbar vertebra (L4) in a paediatric population, with specific attention to sexual dimorphism. The study aims to understand morphological and density changes in the vertebrae through age-dependent statistical shape and statistical appearance models, which can describe full three-dimensional anatomy. Results show that the main growth patterns are associated with isotropic volumetric vertebral growth, a decrease in the relative size of the vertebral foramen, and an increase in the length of the transverse processes.

View Article and Find Full Text PDF

While finite element (FE) models have been used extensively in orthopedic studies, validation of their outcome metrics has been limited to comparison against ex vivo testing. The aim of this study was to validate FE model predictions of the initial cup mechanical environment against patient-matched in vivo measurements of acetabular cup migration using radiostereometric analysis (RSA). Tailored musculoskeletal and FE models were developed using a combination of three-dimensional (3D) motion capture data and clinical computerized tomography (CT) scans for a cohort of eight individuals who underwent primary total hip replacement and were prospectively enrolled in an RSA study.

View Article and Find Full Text PDF

Background: Finite element modelling methodologies available for assessing femurs with metastases accurately predict strength and pathological fracture risk which has led them to being considered for implementation into the clinic. However, the models available use varying material models, loading conditions, and critical thresholds. The aim of this study was to determine the agreement between finite element modelling methodologies in assessing fracture risk in proximal femurs with metastases.

View Article and Find Full Text PDF

Tibiofemoral geometry influences knee passive motion and understanding their relationship can provide insight into knee function and mechanisms of injury. However, the complexity of the geometric constraints has made characterizing the relationship challenging. The aim of this study was to determine the tibiofemoral bone geometries that explain the variation in passive motion using a partial least squares regression (PLSR) model.

View Article and Find Full Text PDF

Unlabelled: The aim of this study was to investigate the influence of the muscle force contribution and loading cycle discretization on the predicted micromotion and interfacial bone strains in the implanted acetabulum. To this end, a patient specific finite element model of the hemipelvis was developed, based on the CT-scan and gait analysis results, collected as part of the authors' previous work. Outcomes of this study suggests that the acetabular cup micromotion and interfacial bone strains can be predicted just using the joint contact force.

View Article and Find Full Text PDF

Accurate rupture risk assessment of ascending aortic aneurysms is important for reducing aneurysm-related mortality. More recently, computational models have been shown to better predict rupture risk than diameter-based measurements. However, it remains unclear whether finite element (FE) models of the ascending aorta can predict rupture location, and over what timeframe those predictions are reliable.

View Article and Find Full Text PDF

Physical exercise induces spatially heterogeneous adaptation in bone. However, it remains unclear where the changes in BMD and geometry have the greatest impact on femoral neck strength. The aim of this study was to determine the principal BMD-and-geometry changes induced by exercise that have the greatest effect on femoral neck strength.

View Article and Find Full Text PDF

Background: Although aortic root and ascending aortic aneurysms are treated the same, they differ in embryological development and pathological processes. This study examines the microscopic structural differences between aortic root and ascending aortic aneurysms, correlating these features to the macroscopic pathophysiological processes.

Methods: We obtained surgical samples from ascending aortic aneurysms (n = 11), aortic root aneurysms (n = 3), and non-aneurysmal patients (n = 7), Aortic collagen and elastin content were examined via histological analysis, and immunohistochemistry techniques used to determine collagen I, III, and IV subtypes.

View Article and Find Full Text PDF

The objectives of this study were to (1) develop a semiautomated method to obtain lesion volume and bone mineral density (BMD) in terms of Hounsfield units from pelvic computed tomography (CT) scans in three regions of interest, and (2) assess accuracy and reliability of the method based on cadaveric CT scans. Image artefacts due to metal implants reduce CT clarity and are more severe with more than one implant in situ. Therefore, accuracy and reliability tests were performed with varying numbers of total hip arthroplasties implanted.

View Article and Find Full Text PDF

Physical exercise induces spatially heterogeneous bone changes in the proximal femur. Recent advances have enabled 3D dual-energy X-ray Absorptiometry (DXA)-based finite element (FE) models to estimate bone strength. However, its ability to detect exercise-induced BMD and strength changes is unclear.

View Article and Find Full Text PDF

Background: The aortic root has unique embryological development and is a highly sophisticated and complex structure. In studies that report on the biomechanical characteristics of the thoracic aorta, distinction between the aortic root and ascending aorta regions is nonexistent. Our objective is to determine the maximal pressures at which dissection occurs or tissue failure occurs in the aortic root compared to that of the ascending aorta in the presence of aortic aneurysms.

View Article and Find Full Text PDF

Aseptic loosening is the most common indication for revision of cementless acetabular cups and often depends on the primary stability achieved following surgery. Cup designs must be capable of achieving primary stability for a wide variety of individuals and surgical conditions to be successful. Typically, preclinical finite element (FE) testing of cups involves assessing the performance in a single patient and under a limited set of idealized conditions.

View Article and Find Full Text PDF

Metaphyseal augments, such as sleeves, have been introduced to augment the fixation of revision total knee replacement (rTKR) components, and can be used with or without a stem. The effect of sleeve size in combination with stems on the primary stability and load transfer of a rTKR implant in AORI type IIB defects where the defect involves both condyles are poorly understood. The aim of this study was to examine the primary stability of revision tibial tray augmented with a sleeve in an AORI type IIB defect which involves both condyles with loss of cortical and cancellous bone.

View Article and Find Full Text PDF

Primary stability is essential for the success of cementless femoral stems. In this study, patient specific finite element (FE) models were used to assess changes in primary stability due to variability in patient anatomy, bone properties and stem alignment for two commonly used cementless femoral stems, Corail® and Summit® (DePuy Synthes, Warsaw, USA). Computed-tomography images of the femur were obtained for 8 males and 8 females.

View Article and Find Full Text PDF

Total hip replacements must be robust to patient variability for long-term success in the population. The challenge during the design process is evaluating an implant in a diverse population but the computational cost of simulating a population of subject-specific finite element (FE) models is not practical. We examined five strategies to generate representative subsets of subjects from a cohort of 103 implanted hip joint FE models to approximate the variability in output metrics.

View Article and Find Full Text PDF

Successful designs of total hip replacement (THR) need to be robust to surgical variation in sizing and positioning of the femoral stem. This study presents an automated method for comprehensive evaluation of the potential impact of surgical variability in sizing and positioning on the primary stability of a contemporary cementless femoral stem (Corail®, DePuy Synthes). A patient-specific finite element (FE) model of a femur was generated from computed tomography (CT) images from a female donor.

View Article and Find Full Text PDF

Traditionally, diaphyseal stems have been utilized to augment the stability of revision total knee replacement (rTKR) implants. More recently metaphyseal augments, such as sleeves, have been introduced to further augment component fixation. The effect of augments such as stems and sleeves have on the primary stability of a rTKR implant is poorly understood, however it has important implications on the complexity, costs and survivorship of the procedure.

View Article and Find Full Text PDF

The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability.

View Article and Find Full Text PDF

Assessing the sensitivity of a finite-element (FE) model to uncertainties in geometric parameters and material properties is a fundamental step in understanding the reliability of model predictions. However, the computational cost of individual simulations and the large number of required models limits comprehensive quantification of model sensitivity. To quickly assess the sensitivity of an FE model, we built linear and Kriging surrogate models of an FE model of the intact hemipelvis.

View Article and Find Full Text PDF