Unlabelled: We previously evaluated 94 patients (96 shoulders) who underwent reverse shoulder arthroplasty using a central compressive screw with 5.0-mm peripheral locking screws for baseplate fixation and a center of rotation lateral to the glenoid as treatment for end-stage rotator cuff deficiency. The purpose of this study was to report updated results at a minimum follow-up of 10 years.
View Article and Find Full Text PDFBackground: A subset of patients with massive irreparable rotator cuff tears present with retained overhead elevation and pain as their primary complaint. Our aim was to evaluate the outcomes of partial arthroscopic rotator cuff repair with biceps tenotomy and to report the failure rate of this procedure for patients with >5 years of follow-up.
Methods: Thirty-four patients underwent partial rotator cuff repair and biceps tenotomy for treatment of a massive rotator cuff tear.
Purpose: To evaluate multiple preoperative and operative factors that may be predictive of and correlate with acute postoperative pain levels after arthroscopic rotator cuff repair.
Methods: One hundred eighty-one patients underwent arthroscopic rotator cuff surgery along with subacromial decompression and met the inclusion criteria for this study. Postoperative visual analog scale (VAS) scores were obtained on postoperative days 1, 7, and 90.
Background: Treatment of complex three and four-part proximal humeral fractures with hemiarthroplasty in elderly patients has yielded mixed clinical results. Reverse shoulder arthroplasty has emerged as a treatment option for comminuted proximal humeral fractures for these patients. The purpose of the study was to perform a prospective evaluation of patient outcomes comparing hemiarthroplasty and reverse shoulder arthroplasty for the treatment of comminuted proximal humeral fractures in elderly patients.
View Article and Find Full Text PDFBackground: This study prospectively evaluated compliance and outcomes after rotator cuff repair in patients with and without Workers' Compensation claims.
Materials And Methods: From December 2007 to January 2010, 42 consecutive patients with Workers' Compensation claims (Work Comp group), and 50 consecutive patients without a Workers' Compensation claim (non-Work Comp group) underwent arthroscopic rotator cuff repair and were enrolled in this study. Compliance with a postoperative protocol of shoulder immobilization and physical therapy was documented.
Background: This study evaluated patient outcomes and rotator cuff healing after arthroscopic rotator cuff repair using a postoperative physical therapy protocol with early passive motion compared with a delayed protocol that limited early passive motion.
Materials And Methods: The study enrolled 68 patients (average age, 63.2 years) who met inclusion criteria.
Hypothesis/background: Reverse shoulder arthroplasty is being used with greater frequency for patients with severe rotator cuff deficiency. There are several commercially available reverse shoulder devices, each with different glenosphere options. The purpose of this study was to determine: (1) forces at the baseplate-bone interface in glenospheres with centers of rotation located concentrically and eccentrically to the center of the baseplate; and (2) if baseplate-bone forces can be optimized by altering tilt of the baseplate.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
October 2010
Background: The purpose of this study was to describe the pathoanatomy of patients diagnosed with rheumatoid arthritis and rotator cuff deficiency and report their outcomes following reverse shoulder arthroplasty.
Methods: Twenty-one shoulders were evaluated prospectively. Nine had no prior surgery, 9 had a failed rotator cuff repair, and 3 had a failed arthroplasty.
Background: The aim of this study is to document a single surgeon's experience performing revision reverse shoulder arthroplasty after baseplate failure.
Methods: Revision reverse shoulder arthroplasty (RSA) for mechanical failure of the glenoid baseplate after RSA was performed in 14 patients. Clinical and radiographic data were collected preoperatively, prior to baseplate failure, after baseplate failure, and at latest follow-up after revision (average, 33 months).
Background: Evaluations of functional outcomes of reverse shoulder arthroplasty have revealed variable improvements in the range of motion and high rates of scapular notching. The purpose of this study was to systematically examine the impact of surgical factors (location of the glenosphere on the glenoid and tilt angle of the glenosphere on the glenoid) and implant-related factors (implant size, center-of-rotation offset, and humeral neck-shaft angle) on impingement-free abduction motion.
Methods: A computer model was developed to virtually simulate abduction/adduction motion and its dependence on five surgical and implant-related factors.
Chondrolysis following shoulder arthroscopy is a devastating complication, often seen in young patients. After nonoperative measures have been exhausted, there are few treatment options available that reliably improve pain and function. The purpose of this study is to examine the intra-operative findings, radiographic features, and clinical outcomes of a series of patients with chondrolysis following arthroscopic surgery managed with a total shoulder arthroplasty.
View Article and Find Full Text PDFWe developed biomechanical and finite element models, using high-strength polyurethane foam blocks, to represent the glenoid bone/baseplate junction to determine if increasing the distance between the glenoid bone and the center of rotation of the glenosphere increases baseplate motion during static loading in the reverse shoulder design. Although there was a general trend toward increased baseplate motion with increasing distance from the glenoid to the center of rotation, in vitro mechanical testing revealed no significant difference between the 7 glenosphere types tested, with average baseplate motion during 1000 load cycles ranging from 90 mum to 120 mum. Results from the finite element analysis strongly correlated with the in vitro mechanical testing.
View Article and Find Full Text PDFThe purpose of this study was to determine the effects of prosthetic design and surgical technique of reverse shoulder implants on total abduction range of motion and impingement on the inferior scapular neck. Custom implants in three glenosphere diameters (30, 36, and 42 mm), with 3 different centers of rotation offsets (0, +5, and +10 mm), were placed into a Sawbones scapula (Pacific Research Laboratories, Vashon, WA) in 3 different positions: superior, center, and inferior glenoid. Humeral sockets were manufactured with a 130 degrees , 150 degrees , and 170 degrees neck-shaft angle.
View Article and Find Full Text PDF