Linac-based stereotactic radiosurgery (SRS) with planning target volume (PTV) margins <1 mm has become increasingly common in recent years. Optical surface imaging for surface-guided radiation therapy (SGRT) is often used for intra-fraction motion monitoring during these treatments to facilitate the use of a smaller PTV margin by providing real-time quantitative patient positioning information. However, rotating the couch introduces errors to SGRT-reported translations and rotations that can be problematic for SRS treatments with non-coplanar arcs and very small PTV margins.
View Article and Find Full Text PDFA 74-year-old woman with pathologic T4a N1 M0 adenocarcinoma of the cecum, initially treated with right hemicolectomy, developed rising serum carcinoembryonic antigen levels while receiving adjuvant chemotherapy. Re-staging investigations demonstrated two soft tissue metastases in the right abdomen comprised of a retrocolic lesion immediately posterior to the colon and a retroperitoneal lesion with no other sites of metastases. The patient was treated with stereotactic ablative radiotherapy (SABR) to a dose of 40 Gy in five daily fractions to both pericolonic soft tissue metastases simultaneously.
View Article and Find Full Text PDFPurpose: To evaluate the feasibility of an open-source, semi-automated, and reproducible vertex placement tool to improve the efficiency of lattice radiotherapy (LRT) planning. We used polymer gel dosimetry with a Cone Beam CT (CBCT) readout to commission this LRT technique.
Material And Methods: We generated a volumetric modulated arc therapy (VMAT)-based LRT plan on a 2 L NIPAM polymer gel dosimeter using our Eclipse Acuros version 15.
To develop and benchmark a novel 3D dose verification technique consisting of polymer gel dosimetry (PGD) with cone-beam-CT (CBCT) readout through a two-institution study. The technique has potential for wide and robust applicability through reliance on CBCT readout..
View Article and Find Full Text PDFPurpose: Deep learning-based auto-segmentation algorithms can improve clinical workflow by defining accurate regions of interest while reducing manual labor. Over the past decade, convolutional neural networks (CNNs) have become prominent in medical image segmentation applications. However, CNNs have limitations in learning long-range spatial dependencies due to the locality of the convolutional layers.
View Article and Find Full Text PDF. The development of radiation-induced fibrosis after stereotactic ablative radiotherapy (SABR) can obscure follow-up images and delay detection of a local recurrence in early-stage lung cancer patients. The objective of this study was to develop a radiomics model for computer-assisted detection of local recurrence and fibrosis for an earlier timepoint (<1 year) after the SABR treatment.
View Article and Find Full Text PDFBackground: The recent trend toward 10 MV for volumetric radiotherapy treatment such as volumetric modulated arc therapy (VMAT), stereotactic radiosurgery (SRS), and stereotactic ablative body radiotherapy (SABR) introduces photoneutron production, with implications for non-therapeutic patient dose and additional shielding requirements for treatment room design. The sharply nonlinear drop-off in photoneutron production below 10 MV to negligible at 6 MV has scarcely been characterized quantitatively, yet can elucidate important practical insights.
Purpose: To measure photoneutron yields in a medical linac at 8 MV, which may strike a reasonable balance between usefully increased beam penetration and dose rate as compared to 6 MV while reducing photoneutron production which is present at 10 MV.
Background And Purpose: Stereotactic ablative radiotherapy (SABR) for oligometastases may improve survival, however concerns about safety remain. To mitigate risk of toxicity, target coverage was sacrificed to prioritize organs-at-risk (OARs) during SABR planning in the population-based SABR-5 trial. This study evaluated the effect of this practice on dosimetry, local recurrence (LR), and progression-free survival (PFS).
View Article and Find Full Text PDFImportance: After the publication of the landmark SABR-COMET trial, concerns arose regarding high-grade toxic effects of treatment with stereotactic ablative body radiotherapy (SABR) for oligometastases.
Objective: To document toxic effects of treatment with SABR in a large cohort from a population-based, provincial cancer program.
Design, Setting, And Participants: From November 2016 to July 2020, 381 patients across all 6 cancer centers in British Columbia were treated in this single-arm, phase 2 trial of treatment with SABR for patients with oligometastatic or oligoprogressive disease.
Radiomics is an advanced image-processing framework, which extracts image features and considers them as biomarkers towards personalized medicine. Applications include disease detection, diagnosis, prognosis, and therapy response assessment/prediction. As radiation therapy aims for further individualized treatments, radiomics could play a critical role in various steps before, during and after treatment.
View Article and Find Full Text PDFStereotactic body radiotherapy (SBRT) planning target volume (PTV) margins are influenced by multiple factors. Data is limited on intrafraction motion in bone SBRT, particularly non-spine lesions. We analyzed intrafraction motion in bone SBRT patients treated on a standard treatment couch without 6 degrees-of-freedom (6-DOF) correction.
View Article and Find Full Text PDFBackground During the novel coronavirus disease 2019 (COVID-19) pandemic, cancer centers considered shortened courses of radiotherapy to minimize the risk of infectious exposure of patients and staff members. Amidst a pandemic, the process of implementing new treatment approaches can be particularly challenging in larger institutions with multiple treatment centers. We describe the implementation of single-fraction (SF) lung stereotactic ablative radiotherapy (SABR) in a multicenter provincial cancer program.
View Article and Find Full Text PDFSurvival from partial-body irradiation (PBI) may be limited by the development of the late lung injury response of pneumonitis. Herein we investigated the hypothesis that acute hematopoietic depletion alters the onset and severity of lung disease in a mouse model. To establish depletion, C3H/HeJ mice received 8 Gy PBI with shielding of only the tibiae, ankles and feet.
View Article and Find Full Text PDFInstitutions use a range of different detector systems for patient-specific quality assurance (QA) measurements conducted to assure that the dose delivered by a patient's radiotherapy treatment plan matches the calculated dose distribution. However, the ability of different detectors to detect errors from different sources is often unreported. This study contains a systematic evaluation of Sun Nuclear's ArcCHECK in terms of the detectability of potential machine-related treatment errors.
View Article and Find Full Text PDFBackground: Oligometastases refer to a state of disease where cancer has spread beyond the primary site, but is not yet widely metastatic, often defined as 1-3 or 1-5 metastases in number. Stereotactic ablative radiotherapy (SABR) is an emerging radiotherapy technique to treat oligometastases that require further prospective population-based toxicity estimates.
Methods: This is a non-randomized phase II trial where all participants will receive experimental SABR treatment to all sites of newly diagnosed or progressing oligometastatic disease.
The aim of this study is to determine whether stereotactic body radiotherapy for multiple vertebral metastases treated with a single isocenter results in greater intrafraction errors than stereotactic body radiotherapy for single vertebral metastases and to determine whether the currently used spinal cord planning organ at risk volume and planning target volume margins are appropriate. Intrafraction errors were assessed for 65 stereotactic body radiotherapy treatments for vertebral metastases. Cone beam computed tomography images were acquired before, during, and after treatment for each fraction.
View Article and Find Full Text PDFPurpose: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented.
Methods: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team.
Purpose: To evaluate the residual setup error and intrafraction motion following kilovoltage cone-beam CT (CBCT) image guidance, for immobilized spine stereotactic body radiotherapy (SBRT) patients, with positioning corrected for in all six degrees of freedom.
Methods And Materials: Analysis is based on 42 consecutive patients (48 thoracic and/or lumbar metastases) treated with a total of 106 fractions and 307 image registrations. Following initial setup, a CBCT was acquired for patient alignment and a pretreatment CBCT taken to verify shifts and determine the residual setup error, followed by a midtreatment and posttreatment CBCT image.
Spinal metastases are a relatively common manifestation in advanced cancer patients. Low-dose conventional radiotherapy has long been the mainstay of treatment under the assumption that patients have a limited life expectancy in the order of 3-6 months. However, with new developments in systemic therapies, patients are surviving longer than expected.
View Article and Find Full Text PDFStereotactic body radiotherapy (SBRT) is an emerging technique for spinal tumours that is a natural succession to brain radiosurgery. The spine is an ideal site for SBRT due to its relative immobility and the potential clinical benefits of high dose delivery, particularly to optimise local control and avoid disease progression that can result in spinal cord compression. However, the proximity of the tumour to the spinal cord, with the potential for radiation myelopathy if the dose is delivered inaccurately or if the spinal cord dose limit is set too high, demands technical accuracy with radiation myelopathy a feared complication.
View Article and Find Full Text PDFTechnol Cancer Res Treat
December 2010
The purpose of this investigation was to study apparatus-dependent dose distribution differences specific to spine stereotactic body radiotherapy (SBRT) treatment planning. This multi-institutional study was performed evaluating an image-guided robotic radiosurgery system (CK), intensity modulated protons (IMP), multileaf collimator (MLC) fixed-field IMRT with 5 mm (11 field), 4 mm (9 field), and 2.5 mm (8- and 9-field) leaf widths and intensity modulated volumetric arc therapy (IMVAT) with a 2.
View Article and Find Full Text PDFDigital subtraction angiography is being supplanted by three-dimensional imaging techniques in many clinical applications, leading to extensive use of maximum intensity projection (MIP) images to depict volumetric vascular data. The MIP algorithm produces intensity profiles that are different than conventional angiograms, and can also increase the vessel-to-tissue contrast-to-noise ratio. We evaluated the effect of the MIP algorithm in a clinical application where quantitative vessel measurement is important: internal carotid artery stenosis grading.
View Article and Find Full Text PDFBackground And Purpose: Clinical trials have shown that carotid endarterectomy reduces stroke risk in symptomatic individuals with severe internal carotid artery (ICA) stenosis. As a result of these trials, digital subtraction angiography (DSA) became a standard of reference for ICA stenosis diagnosis. Newer 3D techniques provide a larger number of views than DSA, which may influence the estimated degree of stenosis.
View Article and Find Full Text PDF