Publications by authors named "Derek D'souza"

Computational anatomical models have many applications in paediatric radiotherapy. Age-specific computational anatomical models were historically developed to represent average and/or healthy individuals, where cancer patients may present with anatomical variations caused by the disease and/or treatment effects. We developed RT-PAL, a library of computational age-specific voxelized anatomical models tailored to represent the paediatric radiotherapy population.

View Article and Find Full Text PDF

Objectives: To identify variables predicting interfractional anatomical variations measured with cone-beam CT (CBCT) throughout abdominal paediatric radiotherapy, and to assess the potential of surface-guided radiotherapy (SGRT) to monitor these changes.

Methods: Metrics of variation in gastrointestinal (GI) gas volume and separation of the body contour and abdominal wall were calculated from 21 planning CTs and 77 weekly CBCTs for 21 abdominal neuroblastoma patients (median 4 years, range: 2 - 19 years). Age, sex, feeding tubes, and general anaesthesia (GA) were explored as predictive variables for anatomical variation.

View Article and Find Full Text PDF

. Adaptive radiotherapy workflows require images with the quality of computed tomography (CT) for re-calculation and re-optimisation of radiation doses. In this work we aim to improve the quality of on-board cone beam CT (CBCT) images for dose calculation using deep learning.

View Article and Find Full Text PDF

Background And Purpose: State-of-the-art radiotherapy modalities have the potential of reducing late effects of treatment in childhood cancer survivors. Our aim was to investigate the carcinogenic risk associated with 3D conformal (photon) radiation (3D-CRT), intensity modulated arc therapy (IMAT) and pencil beam scanning proton therapy (PBS-PT) in the treatment of paediatric abdominal neuroblastoma.

Materials And Methods: The risk of radiation-induced second malignant neoplasm (SMN) was estimated using the concept of organ equivalent dose (OED) for eleven organs (lungs, rectum, colon, stomach, small intestine, liver, bladder, skin, central nervous system (CNS), bone, and soft tissues).

View Article and Find Full Text PDF

Background: Over half a million individuals are diagnosed with head and neck cancer each year globally. Radiotherapy is an important curative treatment for this disease, but it requires manual time to delineate radiosensitive organs at risk. This planning process can delay treatment while also introducing interoperator variability, resulting in downstream radiation dose differences.

View Article and Find Full Text PDF

Reducing radiation-induced side effects is one of the most important challenges in paediatric cancer treatment. Recently, there has been growing interest in using spatial normalisation to enable voxel-based analysis of radiation-induced toxicities in a variety of patient groups. The need to consider three-dimensional distribution of doses, rather than dose-volume histograms, is desirable but not yet explored in paediatric populations.

View Article and Find Full Text PDF

Purpose: In pencil beam scanning proton therapy, target coverage is achieved by scanning the pencil beam laterally in the x- and y-directions and delivering spots of dose to positions at a given radiological depth (layer). Dose is delivered to the spots on different layers by pencil beams of different energy until the entire volume has been irradiated. The aim of this study is to investigate the implementation of proton planning parameters (spot spacing, layer spacing and margins) in four commercial proton treatment planning systems (TPSs): Eclipse, Pinnacle , RayStation and XiO.

View Article and Find Full Text PDF

Studies conducted by the University of Haifa, Israel in 2001, evaluating the effectiveness of bioethics being taught in medical colleges, suggested that there was a significant lack of translation in clinical care. Analysis also revealed, ineffectiveness with the teaching methodology used, lack of longitudinal integration of bioethics into the undergraduate medical curriculum, and the limited exposure to the technology in decision making when confronting ethical dilemmas. A modern novel bioethics curriculum and innovative methodology for teaching bioethics for the medical course was developed by the UNESCO Chair in Bioethics, Haifa.

View Article and Find Full Text PDF

Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image registration to determine the motion from a number of dynamic images, and then fitting a correspondence model relating the motion to the surrogate signals. In this paper we present a generalized framework that unifies the image registration and correspondence model fitting into a single optimization.

View Article and Find Full Text PDF

Theoretical stopping power values were inter-compared for the Bichsel, Janni, ICRU and Schneider relative stopping power (RSP) estimation models, for a variety of tissues and tissue substitute materials taken from the literature. The RSPs of eleven plastic tissue substitutes were measured using Bragg peak shift measurements in water in order to establish a gold standard of RSP values specific to our centre's proton beam characteristics. The theoretical tissue substitute RSP values were computed based on literature compositions to assess the four different computation approaches.

View Article and Find Full Text PDF

Purpose: The aim of this study was to assess whether clinically acceptable segmentations of organs at risk (OARs) in head and neck cancer can be obtained automatically and efficiently using the novel "similarity and truth estimation for propagated segmentations" (STEPS) compared to the traditional "simultaneous truth and performance level estimation" (STAPLE) algorithm.

Methods: First, 6 OARs were contoured by 2 radiation oncologists in a dataset of 100 patients with head and neck cancer on planning computed tomography images. Each image in the dataset was then automatically segmented with STAPLE and STEPS using those manual contours.

View Article and Find Full Text PDF

With the number of new proton centers increasing rapidly, there is a need for an assessment of the available proton treatment planning systems (TPSs). This study compares the dose distributions of complex meningioma plans produced by three proton TPSs: Eclipse, Pinnacle3, and XiO. All three systems were commissioned with the same beam data and, as best as possible, matched configuration settings.

View Article and Find Full Text PDF

Background: Remodelling of bone in the form of resorption generally follows the extraction of a tooth. During all stages of atrophy of the alveolar ridge, characteristic shapes result from the resorptive process, as influenced by anatomic alterations in the alveolar bone. Various ridge augmentation procedures have been documented as predictable means of establishing new vital bone for implant placement, out of which distraction osteogenesis is one such modality.

View Article and Find Full Text PDF

A new potential quality assurance (QA) method is explored (including assessment of depth dose, dose linearity, dose rate linearity and beam profile) for clinical electron beams based on imaging Cerenkov light. The potential of using a standard commercial camera to image Cerenkov light generated from electrons in water for fast QA measurement of a clinical electron beam was explored and compared to ionization chamber measurements. The new method was found to be linear with dose and independent of dose rate (to within 3%).

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the appropriateness of using computed tomography (CT) to cone-beam CT (CBCT) deformable image registration (DIR) for the application of calculating the "dose of the day" received by a head and neck patient.

Methods: NiftyReg is an open-source registration package implemented in our institution. The affine registration uses a Block Matching-based approach, while the deformable registration is a GPU implementation of the popular B-spline Free Form Deformation algorithm.

View Article and Find Full Text PDF

The standard European radiotherapy technique for children with neuroblastoma is a conventional parallel opposed pair. This frequently results in compromise on planning target volume coverage to stay within normal tissue tolerances. This study investigates the use of an intensity-modulated arc therapy (IMAT) technique to improve dose distribution and allow better protocol compliance.

View Article and Find Full Text PDF

Unlabelled: This study tested the principle that (68)Ga-DOTATATE PET/CT may be used to select children with primary refractory or relapsed high-risk neuroblastoma for treatment with (177)Lu-DOTATATE and evaluated whether this is a viable therapeutic option for those children.

Methods: Between 2008 and 2010, 8 children with relapsed or refractory high-risk neuroblastoma were studied with (68)Ga-DOTATATE PET/CT. The criterion of eligibility for (177)Lu-DOTATATE therapy was uptake on the diagnostic scan equal to or higher than that of the liver.

View Article and Find Full Text PDF

A revolution is challenging the dogma that local treatment for all patients with breast cancer treated with breast conservation therapy must include postoperative radiotherapy delivered to the whole breast. Such prolonged postoperative radiotherapy is a burden to patients and hospitals and forces many women to chose mastectomy instead. Furthermore, for patients receiving chemotherapy, the start of conventional radiotherapy may be delayed so long as to increase the risk of local relapse.

View Article and Find Full Text PDF

Postoperative radiotherapy, which forms part of breast-conserving therapy, may not need to encompass the whole breast. Apart from the consumption of huge resources and patients' time, postoperative radiotherapy deters many women from receiving the benefits of breast-conserving surgery, forcing them to choose a mastectomy instead. If radiotherapy could be given in the operating theatre immediately after surgery, many of these disadvantages could be overcome.

View Article and Find Full Text PDF

Aim: We believe that conservative treatment of early breast cancer may not require radiotherapy that encompasses the whole breast in all patients. We have developed a novel therapeutic approach that allows targeted intraoperative radiotherapy (Targit) to be safely and accurately delivered in a standard operating theatre. We are currently recruiting for a randomized trial testing whether Targit can replace the whole 6 weeks of post-operative radiotherapy after breast conserving surgery.

View Article and Find Full Text PDF