Background: Highly cross-linked polyethylene (HXLPE) acetabular bearing surfaces have appeared to offer excellent wear resistance, low incidence of wear-related osteolysis, and high implant survivorship at 10-year to 15-year follow-up. However, concerns over potential performance deterioration at longer-term follow-up remain - particularly in younger patients - and outcome data into the third decade have not been available.
Methods: We retrospectively assessed 62 patients (68 hips) who underwent primary total hip arthroplasty (THA) at age ≤50 years with a single manufacturer's cementless components, remelted HXLPE liner, and small diameter (26 and 28 millimeter) cobalt-chromium (CoCr) femoral heads at minimum 18-year follow-up.
Background: Although femoral osteoplasty is common practice in treating cam-type femoroacetabular impingement (FAI), long-term data are lacking that support the ability of this procedure to optimize outcomes and alter natural history.
Purpose: To compare long-term clinical outcomes and survivorship of treatment for symptomatic FAI via arthroscopic correction of labral or chondral pathology with and without femoral osteoplasty.
Study Design: Cohort study; Level of evidence, 3.
Background: Conventional polyethylene (CPE) was used widely in the past as a bearing surface in total hip arthroplasty (THA). As CPE THAs age and the revision burden continues to grow, it is increasingly important to understand the durability and failure mechanisms of this bearing material. Currently, such long-term data remain limited, particularly in younger, more active patients in whom wear issues are of greater concern.
View Article and Find Full Text PDF