Publications by authors named "Demei Liang"

In this study, a sensitive, rapid, homogeneous, and high-throughput fluorescence polarization immunoassay (FPIA) for the rapid screening of eight glucocorticoids (GCs) in beef samples was successfully established. Two tracers including 5-aminofluorescein-labeled dexamethasone (5-AF-DMS) and fluorescein isothiocyanate-labeled dexamethasone (FITC-DMS) were studied to select appropriate antibody-tracer pairs using four previously produced broad-specific monoclonal antibodies. An optimal combination of the antibody 12D9 and the tracer FITC-DMS was selected.

View Article and Find Full Text PDF

In this study, we developed a novel, simple, rapid, and low-cost colloidal gold-based immunochromatography method, with filter paper replacing nitrocellulose membrane as the substrate. To obtain adequately immobilized protein, chitosan was used to functionalize the filter paper. After conditions and parameters were optimized, the novel immunochromatography method was applied for detection of sulfonamide residues in milk.

View Article and Find Full Text PDF

Antibiotic residues are major contaminants in milk because of their use in agriculture and animal husbandry. In particular, streptomycin, an aminoglycoside antibiotic, is a potential risk to consumers because of its ototoxicity, anaphylaxis, and growth inhibition. Herein, monoclonal antibodies for streptomycin were conjugated with europium microspheres to serve as detection probes for the development of a chromatographic time-resolved fluoroimmunoassay to detect streptomycin residues in milk.

View Article and Find Full Text PDF

A recombinant single-chain variable fragment (scFv) antibody was produced from a hybridoma cell strain secreting the monoclonal antibody for amantadine (AMD), and then its recognition mechanisms for AMD were studied using the molecular docking and molecular dynamics. Complex dockings revealed that three regions are involved in antibody recognition; framework 2 of the VL chain (LFR2) GLU40 and TYR42, complementarity-determining region of the VL chain (LCDR3) TYR116, and framework 2 of the VH chain (HFR2) HIS40 and TRP52 were the key amino acid residues. The results of molecular dynamics show that the most important amino acid residues in the interaction between AMD and scFv are HIS40 and TYR116.

View Article and Find Full Text PDF

A method is described to enhance the sensitivity of an immunochromatographic assay for clenbuterol (CLE) by making use of dually-labeled gold nanoparticles (GNPs), background fluorescence blocking, and immunomagnetic separation. The GNPs were labeled with biotinylated antibody and streptavidin, respectively, and dually labeled GNPs were obtained via the biotin-streptavidin interaction to amplify the detection signal. The fluorescent signal was blocked by dually labeled GNPs and decreased as the dually labeled GNPs aggregation increases on nitrocellulose membrane, which derived from fluorescent polyvinylchloride card.

View Article and Find Full Text PDF

A multiplex lateral flow immunoassay sensor based on highly luminescent green-emitting Au nanoclusters (AuNCs-MLFIA sensor) was successfully established for the simultaneous and quantitative determination of clenbuterol (Clen) and ractopamine (RAC) in swine urine. The antigens of Clen and RAC were dispersed on a nitrocellulose membrane as two test lines, and the Au nanoclusters were synthesized from 6-aza-2-thiothymine and l-arginine to obtain highly green luminescence and ultra-small nanoparticles (Arg/ATT/AuNCs). Free carboxyl groups on Arg/ATT/AuNCs enabled conjugation with biomolecules to afford an indicator for the biosensor.

View Article and Find Full Text PDF

Six aflatoxins (AFs; AF B, B, G, G, M and M) and six zearalenone (ZEN) analogs (ZEN, zearalanone, α-zeralanol, β-zeralanol, α-zearalenol, and β-zearalenol) were simultaneously extracted from edible and medicinal herbs using a group-specific immunoaffinity column (IAC) and then identified by ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). The IAC was prepared by coupling N-hydroxysuccinimide-activated Sepharose 4B Fast Flow gel with two group-specific monoclonal antibodies. The column capacities to six AFs and six ZEN analogs ranged from 100.

View Article and Find Full Text PDF