Background: Early coronary occlusion detection by portable personal device with limited number of electrocardiographic (ECG) leads might shorten symptom-to-balloon time in acute coronary syndromes.
Objectives: The purpose of this study was to compare the accuracy of coronary occlusion detection using vectorcardgiographic analysis of a near-orthogonal 3-lead ECG configuration suitable for credit card-size personal device integration with automated and human 12 lead ECG interpretation.
Methods: The 12-lead ECGs with 3 additional leads ("abc") using 2 arm and 2 left parasternal electrodes were recorded in 66 patients undergoing percutaneous coronary intervention prior to ("baseline", n = 66), immediately before ("preinflation", n = 66), and after 90-second balloon coronary occlusion ("inflation", n = 120).
: Atrial fibrillation (AF), a prevalent cardiac arrhythmia, significantly impacts the quality of life of those affected. The preferred treatment for symptomatic AF, particularly when pharmacological methods fall short, is catheter ablation with pulmonary vein isolation (PVI). While common pulmonary vein (PV) anatomical variants, such as the right accessory pulmonary vein and the common ostium of left pulmonary veins (LCPV), have been studied extensively, their impact on the long-term outcome of PVI is known to be minimal.
View Article and Find Full Text PDFIntroduction: In this study, we sought to determine whether myocardial contractile reserve (CR) assessed by dobutamine stress echocardiography (DSE) can identify patients who experience nearly complete normalization of left ventricular (LV) function after the implantation of a cardiac resynchronization therapy (CRT) pacemaker.
Material And Methods: The study group consisted of 55 consecutive patients with non-ischemic dilated cardiomyopathy, LV ejection fraction (LVEF) < 35%, and prolonged QRS complex duration, who were scheduled for CRT pacemaker implantation. The DSE (20 µg/kg/min) was performed in all patients.
Background: Despite the advancement of technology in electroanatomic mapping systems (EAMS), fluoroscopy remains a necessary, basic imaging modality for electrophysiology procedures. We present a feasibility study of new software that enables 3D-augmented fluoroscopy in biplane catheterization laboratories for planning and guidance of pulmonary vein isolation (PVI). The computer-assisted overlay registration accuracy was assessed in a clinical setting using an automatic calculation of overlay projection geometry that was derived from hardware sensors in C-arms, detectors, and patient table.
View Article and Find Full Text PDFUnlabelled: Differential diagnosis of symptomatic events in post-ablation atrial fibrillation (AF) patients (pts) is important; in particular, accurate, reliable detection of AF or atrial flutter (AFL) is essential. However, existing remote monitoring devices usually require attached leads and are not suitable for prolonged monitoring; moreover, most do not provide sufficient information to assess atrial activity, since they generally monitor only 1-3 ECG leads and rely on RR interval variability for AF diagnosis. A new hand-held, wireless, symptom-activated event monitor (CardioBip; CB) does not require attached leads and hence can be conveniently used for extended periods.
View Article and Find Full Text PDFObjective: Atrial fibrillation (AF) surveillance using a wireless handheld monitor capable of 12-lead electrocardiogram reconstruction was performed, and arrhythmia detection rate was compared with serial Holter monitoring.
Methods: Twenty-five patients were monitored after an AF ablation procedure using the hand-held monitor for 2 months immediately after and then for 1 month approximately 6 months postablation. All patients underwent 12-lead 24-hour Holter monitoring at 1, 2, and 6 months postablation.
Annu Int Conf IEEE Eng Med Biol Soc
March 2011
Unlabelled: Remote surveillance is important for patients with atrial fibrillation (AF). Atrial signal recognition with conventional monitoring devices is difficult; remote AF detection is predominantly accomplished by R-R interval analysis. Twelve lead ECG (12L) displays atrial activity and remains the gold standard for AF diagnosis.
View Article and Find Full Text PDFIntroduction: We described the first case of oversensing due to electric shock in Serbia, in a 54-year-old man who had implantable cardioverter-defibrillator (ICD).
Case Outline: In July 2002, the patient had acute anteroseptal myocardial infarction and ventricular fibrillation (VF) which was terminated with six defibrillation shocks of 360 J. Coronary angiography revealed 30% stenosis of circumflex artery, the left anterior descending coronary artery was recanalized and the right coronary artery was without stenosis.
Background: Brugada syndrome (BS) is a disorder characterized by syncope or sudden death associated with one of several electrocardiographic (ECG) patterns characterized by incomplete right bundle branch block and ST elevation in the anterior precordial leads. Patients with BS are prone to develop ventricular tachyarrhythmias that may lead to syncope, cardiac arrest, or sudden cardiac death.
Case Report: A 58-year-old woman is the first described case of Brugada syndrome in Serbia with intermittent typical changes in basic electrocardiography (ECG): ST segment elevation in the precordial chest leads like dome or coved--major form or type I.
Introduction: This study examines the effect of operator experience on radiofrequency ablation (RFA) of accessory pathways success rate in patients with Wolff-Parkinson-White (WPW) syndrome.
Material And Methods: The first 100 consecutive patients with WPW syndrome treated by radiofrequency ablation at our Clinic, were divided into group A (first 50 patients) and group B (the following 50 patients). Various parameters were compared between these 2 groups.
Introduction: Radiofrequency ablation (RFA) of accessory pathways (AP) is the first line therapy in symptomatic patients with preexcitation syndrome, resistant to medical therapy.
Objective: To evaluate the influence of AP location on RFA effectiveness.
Method: The study compared RFA results of AP located on the left side, right side, and in septal area of the heart in the first 101 consecutive patients treated at Dedinje Cardiovascular Institute in Belgrade.
Ann Noninvasive Electrocardiol
January 2006
Background: It has been shown that mortality risk in patients after myocardial infarction could be estimated by heart rate turbulence (HRT), a short-term change in heart rate after ventricular premature beat (VPB), presumably caused by baroreceptor mechanism. We sought to determine whether pharmacological blockade with atropine, or augmentation of vagal tone with pirenzepine given in small doses would influence HRT.
Methods: In 30 patients with normal echocardiogram, and without signs or symptoms of coronary artery disease, after electrophysiologic examination or radiofrequency ablation for supraventricular arrhythmias was completed, turbulence onset (TO) and turbulence slope (TS) in basal state, after 1.
Pacing Clin Electrophysiol
December 2005
Background: The definition of symptomatic improvement after pulmonary vein isolation (PVI) is controversial. We assessed primarily the usefulness and predictive accuracy (PA) of AF (atrial fibrillation) burden (AFB) within the first 3 months after the procedure as an early predictor for curative success as well as reduction of symptoms.
Methods: We studied 100 pts (62 men, mean age: 54 +/- 9 years, LVEF: 57 +/- 9%, paroxysmal AF, 85, persistent AF, 15) who underwent PVI.