Publications by authors named "Deisenhofer I"

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017.

View Article and Find Full Text PDF
Article Synopsis
  • Left ventricular assist devices (LVADs) are commonly used to treat advanced heart failure, improving survival but leading to high rates of arrhythmias (20-50%) within a year after implantation.
  • Arrhythmias in these patients increase the risk of complications, such as additional shocks from implantable defibrillators and potential worsening of right ventricular failure, highlighting the need for tailored management strategies.
  • Effective treatment for these arrhythmias may involve specialized approaches like catheter ablation, though unique challenges exist in accessing arrhythmogenic areas after LVAD surgery, making pre-implantation procedures potentially beneficial.
View Article and Find Full Text PDF

The question of optimal timing for catheter ablation of atrial fibrillation (AF) to achieve best outcomes remains a crucial clinical issue. As AF occurs less frequently in younger patients, data regarding Diagnosis-to-Ablation Time (DAT) is especially limited in patients under the age of 55 years with persistent AF. We therefore analyzed the temporal relationship between initial AF presentation and timing of catheter ablation in this cohort.

View Article and Find Full Text PDF

Background: Pulsed field ablation (PFA) has become increasingly important in the treatment of cardiac arrhythmias. In addition to single-shot devices mainly used for pulmonary vein isolation, focal PFA may provide a treatment option that increases the versatility of the technique.

Objective: The purpose of this study was to provide data on feasibility, safety, and long-term outcome of focal PFA for ablation of complex atrial tachycardia (AT).

View Article and Find Full Text PDF

Background: Pulse field ablation (PFA) is a novel catheter ablation technology with potential safety benefits due to its tissue selectivity. It has the potential to directly damage or interact with the functionality of cardiac implantable electronic devices (CIEDs) in the form of electromagnetic interference (EMI). The aim of our study was to assess the impact of PFA on CIEDs.

View Article and Find Full Text PDF

Background: Lesion durability and transmurality are crucial for successful radiofrequency (RF) ablation. This study provides a model of real-time RF lesion visualization and insights into the role of underlying parameters, as local impedance (LI).

Methods: A force-sensing, LI-sensing catheter was used for lesion creation in an ex vivo model involving cross-sections of porcine cardiac preparations.

View Article and Find Full Text PDF
Article Synopsis
  • The BEAT PAROX-AF trial is a European study comparing pulsed field ablation (PFA) with radiofrequency (RF) ablation for treating drug-resistant paroxysmal atrial fibrillation (AF), focusing on efficacy and safety.
  • A total of 292 participants were randomly assigned to either PFA or RF using specific protocols to measure outcomes such as the recurrence of atrial arrhythmia and serious adverse events.
  • The study began in December 2021 and will conclude recruitment in January 2024, with results expected to be published in mid-2025, aiming to improve treatment strategies for patients with paroxysmal AF.
View Article and Find Full Text PDF
Article Synopsis
  • Ablation of atrial fibrillation (AF) has become a widely accepted and effective treatment for managing this common heart rhythm disorder over the last 30 years.
  • Since the initial consensus document in 2007, new research and technologies have significantly changed AF ablation practices, necessitating updates in 2012 and 2017.
  • A new consensus document was recently created by various cardiac societies to provide a current framework for selecting and managing patients for catheter or surgical AF ablation, reflecting the evolving nature of the field.
View Article and Find Full Text PDF
Article Synopsis
  • * The first expert guidelines for AF ablation were published in 2007, and updates were necessary in 2012 and 2017 due to advancements in research and technology.
  • * A new consensus document is now being released to provide updated guidelines for healthcare professionals on selecting and managing patients for AF ablation, created by various international cardiac societies.
View Article and Find Full Text PDF
Article Synopsis
  • Atrial fibrillation (AF) ablation has become a well-established treatment method in the last 30 years, supported by evidence showing it is safe and effective.
  • In response to advancements in research and technology, new guidelines have been released over the years, the latest being necessary to provide updated recommendations for patient care.
  • This revised consensus involves collaboration among major cardiac electrophysiology societies from Europe, Asia-Pacific, and Latin America to ensure comprehensive guidelines for AF treatment.
View Article and Find Full Text PDF

Background: Data regarding uninterrupted oral anticoagulation in patients with chronic kidney disease (CKD) during catheter ablation for left atrial arrhythmias is limited. This study aimed to evaluate the safety and efficacy of periprocedural uninterrupted direct oral anticoagulants (DOAC) compared with uninterrupted phenprocoumon in patients with CKD undergoing left atrial catheter ablation.

Methods And Results: We conducted a retrospective single-center study of patients who underwent left atrial catheter ablation between 2016 and 2019 with underlying chronic kidney disease (glomerular filtration rate (GFR) between 15 and 45 ml/min).

View Article and Find Full Text PDF

Introduction: Despite advanced ablation strategies and major technological improvements, treatment of persistent atrial fibrillation (AF) remains challenging and the underlying pathophysiology is not fully understood. This study analyzed the multiple procedure outcome and safety of catheter ablation of spatiotemporal dispersions (DISPERS) detected by artificial intelligence (AI)-guided software in patients with long-standing persistent AF.

Methods And Results: The Volta VX1 software was used for 50 consecutive patients undergoing catheter ablation for persistent AF.

View Article and Find Full Text PDF

Introduction: The eradication of ventricular tachycardia (VT) isthmus sites constitutes the minimal procedural endpoint for VT ablation procedures. Contemporary high-resolution computed tomography (CT) imaging, in combination with computer-assisted analysis and segmentation of CT data, facilitates targeted elimination of VT isthmi. In this context, inHEART offers digitally rendered three-dimensional (3D) cardiac models which allow preoperative planning for VT ablations in ischemic and non-ischemic cardiomyopathies.

View Article and Find Full Text PDF

Introduction: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) is an established treatment strategy for atrial fibrillation (AF). To improve PVI efficacy and safety, high-power short-duration (HPSD) ablation and pulsed-field ablation (PFA) were recently introduced into clinical practice. This study aimed to determine the extent of myocardial injury and systemic inflammation following PFA, HPSD, and standard RFA using established biomarkers.

View Article and Find Full Text PDF

Background: The aim of this study was to assess long-term efficacy and safety of empirical slow pathway (ESP) ablation in pediatric and adult patients with a special interest in patients without dual AV nodal physiology (DAVNP).

Methods: A retrospective single-center review of patients who underwent ESP ablation between December 2014 and September 2022 was performed. Follow-up included telephone communication, letter questionnaire and outpatient presentation.

View Article and Find Full Text PDF

Background: The influence of power, duration and contact force (CF) on radiofrequency (RF) lesion formation is well known, whereas data on local impedance (LI) and electrode-tissue-coverage (ETC) is scarce. The objective was to investigate their effect on lesion formation in an ex vivo model.

Methods And Results: An ex vivo model was developed utilizing cross-sections of porcine heart preparations and a force-sensing, LI-measuring catheter.

View Article and Find Full Text PDF

Background: The demand for transvenous lead extraction (TLE) has increased. In line with this, the safety of such procedures has also increased. Traditionally, TLE is performed under resource-intensive general anaesthesia.

View Article and Find Full Text PDF

Aims: Battery electric vehicle (BEV) sales and use are rapidly expanding. Battery electric vehicles, along with their charging stations, are a potential source of electromagnetic interference (EMI) for patients with cardiac implantable electronic devices (CIEDs). The new 'high-power' charging stations have the potential to create strong electromagnetic fields and induce EMI in CIEDs, and their safety has not been evaluated.

View Article and Find Full Text PDF

Background: Ventricular tachycardia (VT) originating in the right ventricular outflow tract (RVOT) is the most common form of idiopathic VT. Catheter ablation of right ventricular outflow tract tachycardia (RVOT-VT) is associated with high success rates. However, non-inducibility of VT on electrophysiological (EP) study can severely impact ablation outcome.

View Article and Find Full Text PDF

The term "asymptomatic WPW" (Wolff-Parkinson-White) is often used as a synonym for ventricular pre-excitation of the WPW type due to an accessory pathway characterized by a short PR interval and a delta wave on the electrocardiogram (ECG) without the clinical occurrence of paroxysmal tachycardia. Asymptomatic WPW is often diagnosed in young and otherwise healthy people. There is a small associated risk of sudden cardiac death due to rapid antegrade conduction over the accessory pathway during atrial fibrillation.

View Article and Find Full Text PDF

Aims: This retrospective study sought to compare complication rates and efficacy of power-controlled very high-power short-duration (vHPSD) and conventional catheter ablation in a large cohort of patients with atrial fibrillation (AF).

Methods And Results: We analyzed 1115 consecutive patients with AF (38.7% paroxysmal, 61.

View Article and Find Full Text PDF

Background: Femoral vascular access using the standard anatomic landmark-guided method is often limited by peripheral artery disease and obesity. We investigated the effect of ultrasound-guided vascular puncture (UGVP) on the rate of vascular complications in patients undergoing catheter ablation for atrial or ventricular arrhythmias. Methods: The data of 479 patients (59% male, mean age 68 years ± 11 years) undergoing catheter ablation for left atrial (n = 426; 89%), right atrial (n = 28; 6%) or ventricular arrhythmias (n = 28; 6%) were analyzed.

View Article and Find Full Text PDF

Background: Arrhythmias are a well known complication in patients with single ventricle physiology (SVP). However, there is still a lack of data regarding arrhythmias in older patients. The aim of this study was to analyze arrhythmia type and frequency, treatment and recurrence rates in patients with SVP over the age of 40 years.

View Article and Find Full Text PDF