Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites.
Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors.
Individuals vary greatly in their ability to select one item or response when presented with a multitude of options. Here we investigate the neural underpinnings of these individual differences. Using magnetic resonance spectroscopy, we found that the balance of inhibitory versus excitatory neurotransmitters in pFC predicts the ability to select among task-relevant options in two language production tasks.
View Article and Find Full Text PDFUnlabelled: Insulin resistance is increasingly prevalent in children and may be related to muscle mitochondrial dysfunction, necessitating development of mitochondrial assessment techniques. Recent studies used phosphorus magnetic resonance spectroscopy (P-MRS), a noninvasive technique appealing for clinical research. P-MRS requires exercise at a precise percentage of maximum volitional contraction (MVC).
View Article and Find Full Text PDFImbalanced levels of excitation and inhibition (E/I) have been proposed to account for various behavioral and electrophysiological phenotypes in autism. Although proton magnetic resonance spectroscopy ((1)H-MRS) studies have been published on various metabolite levels in autism, including glutamate, the major excitatory neurotransmitter, few (1)H-MRS studies have yet been conducted the major inhibitory neurotransmitter GABA. Seventeen individuals with autism spectrum disorders (ASD) participated in a single-voxel, point resolved spectroscopy (PRESS) study conducted on a 3T magnet.
View Article and Find Full Text PDFIncreased glutamate levels have been reported in the hippocampal and frontal regions of persons with autism using proton magnetic resonance spectroscopy ((1)H-MRS). Although autism spectrum disorders (ASDs) are highly heritable, MRS studies have not included relatives of persons with ASD. We therefore conducted a study to determine if glutamate levels are elevated in people with autism and parents of children with autism.
View Article and Find Full Text PDFIntroduction: Smooth pursuit eye movements (SPEM) are abnormal in individuals with schizophrenia and individuals with bipolar disorder. Functional imaging methods have revealed greater hippocampal activity and less frontotemporal, visual, and posterior cerebellar activity in individuals with schizophrenia when performing a SPEM task. The underlying neurobiology of SPEM deficits in bipolar disorder is unknown.
View Article and Find Full Text PDF3-(2,4-Dimethoxybenzylidene)-anabaseine (DMXB-A) is a partial agonist at alpha7-nicotinic acetylcholine receptors and is now in early clinical development for treatment of deficits in neurocognition and sensory gating in schizophrenia. During its initial phase 2 test, functional magnetic resonance imaging (fMRI) studies were conducted to determine whether the drug had its intended effect on hippocampal inhibitory interneurons. Increased hemodynamic activity in the hippocampus in schizophrenia is found during many tasks, including smooth pursuit eye movements, and may reflect inhibitory dysfunction.
View Article and Find Full Text PDFQuantitative mapping of the myelin water content can provide significant insight into the pathophysiology of several white matter diseases, such as multiple sclerosis and leukoencephalopathies, and can potentially become a useful clinical tool for early diagnosis of these diseases. In this study, multicompartment analysis of T(2)(*) decay (MCAT(2)(*)) was used for the quantitative mapping of myelin water fraction (MWF). T(2)(*) decay of each voxel at multiple slice locations was acquired in fixed human brains using a multigradient-echo (MGRE) pulse sequence with alternating readout gradient polarities.
View Article and Find Full Text PDF