Background: Patient education is needed to perform home blood pressure measurement (HBPM) according to blood pressure (BP) guidelines. It is not known how BP is measured at home and what education is provided, which was the aim of the study.
Methods: Mixed-methods study among Australian adults who perform HBPM (June to December 2023).
Blood pressure (BP) is a key contributor to the lifetime risk of preclinical organ damage and cardiovascular disease. Traditional clinic-based BP readings are typically measured infrequently and under standardized/resting conditions and therefore do not capture BP values during normal everyday activity. Therefore, current hypertension guidelines emphasize the importance of incorporating out-of-office BP measurement into strategies for hypertension diagnosis and management.
View Article and Find Full Text PDFClinic blood pressure (BP) is recommended for absolute cardiovascular disease (CVD) risk assessment. However, in 'real-world' settings, clinic BP measurement is unstandardised and less reliable compared to more rigorous methods but the impact for absolute CVD risk assessment is unknown. This study aimed to determine the difference in absolute CVD risk assessment using real-world clinic BP compared to standardised BP methods.
View Article and Find Full Text PDFObjectives: Central aortic BP may predict cardiovascular outcomes better than upper arm brachial BP. In recent years, technology has enabled central BP estimation by recording a peripheral BP waveform from a standard upper arm cuff. The accuracy of these devices is not well documented, and this study aimed to address this issue.
View Article and Find Full Text PDFBackground: Measurement of home blood pressure is an important tool for the management of hypertension. However, the validity of home devices is of concern. The Recommended Blood Pressure Devices Program of Hypertension Canada reviews and recommends blood pressure devices using international validation standards.
View Article and Find Full Text PDFObjective: Hypertension management is directed by cuff blood pressure (BP), but this may be inaccurate, potentially influencing cardiovascular disease (CVD) events and health costs. This study aimed to determine the impact on CVD events and related costs of the differences between cuff and invasive SBP.
Methods: Microsimulations based on Markov modelling over one year were used to determine the differences in the number of CVD events (myocardial infarction or coronary death, stroke, atrial fibrillation or heart failure) predicted by Framingham risk and total CVD health costs based on cuff SBP compared with invasive (aortic) SBP.
Automated cuff measured blood pressure (BP) is the global standard used for diagnosing hypertension, but there are concerns regarding the accuracy of the method. Individual variability in systolic BP (SBP) amplification from central (aorta) to peripheral (brachial) arteries could be related to the accuracy of cuff BP, but this has never been determined and was the aim of this study. Automated cuff BP and invasive brachial BP were recorded in 795 participants (74% male, aged 64 ± 11 years) receiving coronary angiography at five independent research sites (using seven different automated cuff BP devices).
View Article and Find Full Text PDFCardiovascular disease (CVD) has long been deemed a disease of old men. However, in 2019 CVD accounted for 35% of all deaths in women and, therefore, remains the leading cause of death in both men and women. There is increasing evidence to show that risk factors, pathophysiology and health outcomes related to CVD differ in women compared with men, yet CVD in women remains understudied, underdiagnosed and undertreated.
View Article and Find Full Text PDFObjective: Accurate measurement of central blood pressure (BP) using upper arm cuff-based methods is associated with several factors, including determining the level of systolic BP (SBP) amplification. This study aimed to determine the agreement between cuff-based and invasively measured SBP amplification.
Methods: Patients undergoing coronary angiography had invasive SBP amplification (brachial SBP - central SBP) measured simultaneously with cuff-based SBP amplification using a commercially available central BP device (device 1: Sphygmocor Xcel; n = 171, 70% men, 60 ± 10 years) and a now superseded model of a central BP device (device 2: Uscom BP+; n = 52, 83% men, 62 ± 10 years).
Background: Accurate blood pressure (BP) measurement is critical for optimal cardiovascular risk management. Age-related trajectories for cuff-measured BP accelerate faster in women compared with men, but whether cuff BP represents the intraarterial (invasive) aortic BP is unknown. This study aimed to determine the sex differences between cuff BP, invasive aortic BP, and the difference between the 2 measurements.
View Article and Find Full Text PDFThe aim of the HEARTS in the Americas initiative is to promote the adoption of global best practices in the prevention and control of cardiovascular diseases, and improve the control of hypertension. HEARTS is being implemented in 21 countries and a diverse set of actions and measures are in progress to improve exclusive access in primary health care facilities to automated blood pressure measuring devices that have been validated for accuracy. The purpose of this manuscript is to illustrate these efforts, mainly in the regulatory and public procurement arena, and to present information on common challenges and solutions identified.
View Article and Find Full Text PDFClinically validated, automated arm-cuff blood pressure measuring devices (BPMDs) are recommended for BP measurement. However, most BPMDs available for purchase by consumers globally are not properly validated. This is a problem because non-validated BPMDs are less accurate and precise than validated ones, and therefore if used clinically could lead to misdiagnosis and mismanagement of BP.
View Article and Find Full Text PDFA recent study found that only 23.8% of blood pressure (BP) devices available for purchase from Australian pharmacies were validated for accuracy. The extent to which pharmacists are aware of this, and other issues related to the accuracy of BP devices, is not known and gathering this information was the aim of this study.
View Article and Find Full Text PDFProfessional societies, guideline writing committees, and other interested parties emphasize the importance of accurate measurement of blood pressure for clinical and public health decisions related to prevention, treatment, and follow-up of high blood pressure. Use of a clinically validated instrument to measure blood pressure is a central component of measurement accuracy and precision. Despite this, most regulatory authorities do not specify validation requirements that manufacturers must meet to sell their blood pressure measurement devices.
View Article and Find Full Text PDFThis study uses data from the publicly available Medaval database to determine the number of upper arm cuff and wrist cuff blood pressure measuring devices sold globally as well as the percentages of those devices that have been clinically validated for accuracy.
View Article and Find Full Text PDFMay Measurement Month (MMM) is an annual global blood pressure (BP) screening campaign aimed at obtaining standardized BP measurements and other relevant health information from members of the community to increase awareness of elevated BP and the associated risks. Adults (≥18 years) were recruited through opportunistic sampling across the various Australian states during May 2019. Three BP readings were recorded in a standardized manner for each participant, and data on lifestyle factors and comorbidities were collected.
View Article and Find Full Text PDFThere is a growing body of evidence indicating that reservoir-excess pressure model parameters provide physiological and clinical insights above and beyond standard blood pressure (BP) and pulse waveform analysis. This information has never been collectively examined and was the aim of this review. Cardiovascular disease is the leading cause of mortality worldwide, with BP as the greatest cardiovascular disease risk factor.
View Article and Find Full Text PDFIsolated systolic hypertension (ISH) is the most common form of hypertension and is highly prevalent in older people. We recently showed differences between upper-arm cuff and invasive blood pressure (BP) become greater with increasing age, which could influence correct identification of ISH. This study sought to determine the difference between identification of ISH by cuff BP compared with invasive BP.
View Article and Find Full Text PDF