Purpose: The study was to determine the effect of locking hole inserts and their insertion torque on the fatigue life of a large fragment Locking Compression Plate (LCP) under bending forces.
Methods: Fatigue strength of the LCP was examined using cyclic three-point bend testing at 80% yield strength of the construct. Locking hole inserts were used in 2, 4, and 6-hole of a 12-hole plate to simulate three different working lengths.
Purpose: To investigate the clinical outcomes following the arthroscopic removal of proximal humerus locking plates for symptomatic hardware after open reduction and internal fixation (ORIF) of proximal humerus fractures.
Methods: Patients who underwent arthroscopic removal of hardware (ROH) with capsular release due to pain and/or immobility after receiving locking plates to treat proximal humerus fractures from 2009 to 2016 were identified. Operative and clinic records were reviewed to obtain demographic information, concomitant procedures during ROH, and pre- and postoperative active shoulder range of motion.
Background: The optimal method for the determination of ankle stability remains controversial in rotational ankle fractures without medial bony injury.
Questions/purposes: The purposes of this study were to (1) evaluate whether posterior malleolar (PM) fracture displacement is associated with deltoid ligament injury in supination-external rotation (SER) ankle fractures and (2) compare the diagnostic accuracy of PM displacement and magnetic resonance imaging (MRI) evaluation of the deep deltoid ligament in identifying fractures with deltoid ligament incompetence.
Methods: Patients with rotational bimalleolar injuries containing lateral malleolar and PM fractures without bony medial injury were included.
Objective: Disrupted blood supply has been proposed as an underlying cause for delayed union in tibial shaft fractures (OTA/AO 42). Although tibial blood supply has been qualitatively evaluated, quantitative studies are lacking. The purpose of this project was to quantify the relative contribution of the endosteal supply to the tibial diaphysis.
View Article and Find Full Text PDFTraumatic injury and surgical intervention about the hip joint place the arterial supply to the femoral head (FH) at risk. Compromised perfusion may lead to FH ischemia, cell death, and osteonecrosis. Progression to FH collapse may lead to pain, functional impairment, and decreased quality of life, especially in younger patients.
View Article and Find Full Text PDFBackground: Operative indications for supination-external rotation (SER) ankle fractures depend on the integrity of the medial structures. Despite the importance of assessing deep deltoid ligament injuries, the accuracy of common diagnostic tests has not been established.
Questions/purposes: The objective of this study was to compare the ability of injury (non-stress) and stress radiographs and magnetic resonance imaging (MRI) to diagnose deep deltoid ligament ruptures in operative SER ankle fractures.
Background: The purpose of this study was to evaluate the effect of ankle plantarflexion and the axial location of measurement on quantitative syndesmosis assessment.
Methods: Twelve fresh-frozen cadaveric specimens were secured in three positions of ankle plantarflexion (0°, 15°, and 30°) using an ankle-spanning external fixator and underwent CT scans at each position. Syndesmotic measurements were obtained on axial images using three previously described methods (six measurements) at the level of the tibial plafond and 1 cm proximal to the plafond.
Recent literature has reported an uncategorized hyperplantarflexion variant ankle fracture characterized by a posteromedial fragment separate from the posterior or medial malleolar fragments. The current study sought to determine whether the outcomes for surgically treated hyperplantarflexion variant fractures are similar to the more common supination external rotation (SER) IV fractures. A prospective registry of operatively treated ankle fractures was queried to create 2 age- and gender-matched cohorts: hyperplantarflexion variant and SER IV fractures.
View Article and Find Full Text PDFAlthough the use of fibular strut allografts in proximal humerus fractures has gained popularity, their use in other types of fractures is less well described. Fibular allografts have recently been used in the repair of complex periarticular fractures of the proximal tibia and distal femur. Fibular allografts can be inserted in a variety of manners to achieve goals specific to each individual fracture pattern.
View Article and Find Full Text PDFGeriatr Orthop Surg Rehabil
January 2019
Introduction: Twenty-five percent to seventy-five percent of independent patients do not walk independently after hip fracture (HF), and many patients experience functional loss. Early rehabilitation of functional status is associated with better long-term outcomes; however, predictors of early ambulation after HF have not been well described.
Purposes: To assess the impact of perioperative and patient-specific variables on in-hospital ambulatory status following low-energy HF surgery.
Background:: Rotational ankle fractures can present with an array of possible osseous and ligamentous injury combinations in reliable anatomic locations. What accounts for these different injury patterns and whether specific patient and injury factors underlie the different injury patterns is unclear. The purpose of this study was to determine whether causative factors exist that could account for the various injury patterns seen with rotational ankle fractures.
View Article and Find Full Text PDFIn physiologically young patients with displaced femoral neck fractures, surgical treatment is aimed at achieving fracture union while preserving native hip anatomy and biomechanics. The intracapsular environment, tenuous vascular supply, and unfavorable hip biomechanics contribute to the high complication rates seen after osteosynthesis of these fractures. Conventional fixation methods for osteosynthesis of femoral neck fractures include multiple cancellous screws, fixed-angle dynamic implants, and fixed-angle length-stable constructs.
View Article and Find Full Text PDFSurgical management of lower extremity malunions and acute fractures in the setting of lower extremity deformities presents a unique challenge for orthopaedic surgeons. The objective of this study was to evaluate the outcomes of using the clamshell osteotomy in patients with acute fractures involving a malunion or deformity. A retrospective review of the cases performed by various orthopaedic traumatologists at 4 different trauma centers was performed to identify cases using the clamshell osteotomy from January 2012 to January 2016.
View Article and Find Full Text PDFObjectives: To report outcomes and complications of periprosthetic distal femur fractures (PPDFF) treated with open reduction internal fixation (ORIF) using a plate construct, with or without endosteal augmentation.
Design: Retrospective Case Series.
Setting: One Level I trauma center and one tertiary care hospital.
Objective: To determine the association between fracture collapse with altered gait after intertrochanteric (IT) fracture using the trochanteric fixation nail (TFN) and helical blade.
Design: Prospective cohort study.
Setting: Academic Level I trauma center.
J Am Acad Orthop Surg Glob Res Rev
October 2017
Case: A 77-year-old woman presented with volar wrist pain 1.5 years after undergoing distal radius volar locked plating for fracture. Radiographs and CT were notable only for plate prominence, and she was admitted for removal of hardware.
View Article and Find Full Text PDFArch Orthop Trauma Surg
December 2018
Introduction: Osteoporosis and decreased bone density are known to increase fracture incidence and severity. Although much is known regarding the effects of bone density on fracture risk and the treatment options for prevention of fragility fractures, whether bone quality alters clinical outcomes after fracture fixation is unknown. The purpose of this study was to determine whether bone quality correlates with clinical outcomes after fracture fixation.
View Article and Find Full Text PDFBackground: Advantages of using computerized adaptive testing (CAT) include decreased survey-burden, diminished floor and ceiling effect, and improved ability to detect the minimal clinical significant difference (MCID) among patients. The goal of this study was to compare the legacy patient-reported outcome measures (PROMs) to the Patient-Reported Outcomes Measurement Information System (PROMIS) scores in terms of ability to detect clinically significant changes in patients who have undergone surgery for ankle fractures.
Methods: Patients who underwent osteosynthesis for an unstable ankle fracture between 2013-2016 and completed legacy outcome scores (Foot and Ankle Outcome Score [FAOS], Olerud and Molander Ankle Score [OMAS], and Weber Score) along with the PROMIS Physical Function (PF) and PROMIS Lower Extremity (LE) CATs postoperatively were included.
Background: Although vascularity plays a critical role in healing after ulnar collateral ligament (UCL) reconstruction, intraosseous blood flow to the medial epicondyle (ME) and sublime tubercle remains undefined.
Purpose: To quantify vascular disruption caused by tunnel drilling with the modified Jobe and docking techniques for UCL reconstruction.
Study Design: Controlled laboratory study.
Am J Orthop (Belle Mead NJ)
March 2018
As the operative management of displaced distal radius fractures evolves, intraoperative techniques and fixation strategies evolve as well. Achieving and maintaining an acceptable reduction is paramount but can be difficult with particular fracture patterns. In this article, we describe the use of a radial column plate as a reduction tool in the management of unstable distal radius fractures, along with clinical and radiographic clinical outcomes.
View Article and Find Full Text PDFBackground: Computerized adaptive testing (CAT) for patient-reported outcomes (PROs) is a developing area within orthopedic surgery. Our objective was to validate the Patient Reported Outcomes Measurement Information System (PROMIS) CATs for upper extremity fracture care. We sought to correlate PROMIS with legacy PROs and to investigate floor and ceiling effects.
View Article and Find Full Text PDFThis study summarizes presentations of a symposium on biomechanically related hot topics of the 2015 Basic Science Focus Forum. Each topic emphasizes a biomechanical challenge common to all 4 of these presentations: an ideal fixation technique should deliver ample stability and sufficient flexibility to prevent fixation failure and to restore normal function.
View Article and Find Full Text PDFObjectives: To evaluate the effect of posterior bony versus ligamentous injury pattern on functional outcomes in operatively treated rotational ankle fractures.
Design: Retrospective cohort analysis of prospective registry.
Setting: Academic Level I trauma center.
Background: The purpose of this study was to quantitatively and qualitatively assess relative arterial contributions to the calcaneus.
Method: Fourteen cadaveric ankle pairs were used. In each specimen, the posterior tibial artery, peroneal artery, and anterior tibial artery were cannulated and used for contrast-enhanced magnetic resonance imaging (MRI) and computed tomography (CT).