Publications by authors named "Dean C Ripple"

Recombinant adeno-associated virus (AAV) is one of the main viral vector-based gene therapy platforms. AAV is a virus consisting of a ≈25 nm diameter capsid with a ≈4.7 kb cargo capacity.

View Article and Find Full Text PDF

Subvisible particles (SVPs) are a critical quality attribute of injectable therapeutic proteins (TPs) that needs to be controlled due to potential risks associated with drug product quality. The current compendial methods routinely used to analyze SVPs for lot release provide information on particle size and count. However, chemical identification of individual particles is also important to address root-cause analysis.

View Article and Find Full Text PDF

Visible protein-like particle standards may improve visual inspection and/or appearance testing practices used in the biotechnology industry. They may improve assay performance resulting in better alignment and more standardized training among different companies. The National Institute of Standards and Technology (NIST) has conducted an interlaboratory study to test whether the standards under development mimic typical proteinaceous particles found in biotherapeutics and if they can be implemented during the visual inspection process.

View Article and Find Full Text PDF

The number of techniques to measure number concentrations and size distributions of submicrometer particles has recently increased. Submicrometer particle standards are needed to improve the accuracy and reproducibility of these techniques. The number concentrations of fluorescently labeled polystyrene submicrometer sphere suspensions with nominal 100 nm, 200 nm and 500 nm diameters were measured using seven different techniques.

View Article and Find Full Text PDF

Objective: Digital microscopy is used to monitor particulates such as protein aggregates within biopharmaceutical products. The images that result encode a wealth of information that is underutilized in pharmaceutical process monitoring. For example, images of particles in protein drug products typically are analyzed only to obtain particle counts and size distributions, even though the images also reflect particle characteristics such as shape and refractive index.

View Article and Find Full Text PDF

The measurement of polydisperse protein aggregates and particles in biotherapeutics remains a challenge, especially for particles with diameters of ≈ 1 µm and below (sub-micrometer). This paper describes an interlaboratory comparison with the goal of assessing the measurement variability for the characterization of a sub-micrometer polydisperse particle dispersion composed of five sub-populations of poly(methyl methacrylate) (PMMA) and silica beads. The study included 20 participating laboratories from industry, academia, and government, and a variety of state-of-the-art particle-counting instruments.

View Article and Find Full Text PDF

Dynamic imaging analysis instruments are used for sizing particles of different types that might appear in a biopharmaceutical. These instruments are calibrated using polystyrene latex microspheres in water, which is a significantly different system than the typical particles imaged in a formulation. We show how the instruments, when reporting an equivalent diameter, set a threshold for image processing and then apply a built-in correction to account for fuzzy boundary effects.

View Article and Find Full Text PDF

Online water bioburden analyzers (OWBAs) can provide real-time feedback on viable bacteria in high-purity water (HPW) systems for pharmaceutical manufacturers. To calibrate and validate OWBAs, which detect bacteria using scattered light and bacterial autofluorescence, standards are needed that mimic the characteristics of bacteria in HPW. To guide selection of potential standards, e.

View Article and Find Full Text PDF

The spatially averaged density of protein aggregates is an important parameter that can be used to relate size distributions measured by orthogonal methods, to characterize protein particles, and perhaps to estimate the amount of protein in aggregate form in a sample. We obtained a series of images of protein aggregates exhibiting Brownian diffusion while settling under the influence of gravity in a sealed capillary. The aggregates were formed by stir-stressing a monoclonal antibody (NISTmAb).

View Article and Find Full Text PDF

Accurate number concentrations of particles in liquid media are needed to assess the quality of water, pharmaceuticals, and other liquids, yet there are limited reference materials or calibration services available with clear traceability to the International System of Units. We describe two methods, based on very simple modifications of commercial particle counter instruments, that can provide traceable number concentration measurements. One method used a light obscuration counter.

View Article and Find Full Text PDF

Nanoparticle tracking analysis (NTA) obtains particle size by analysis of particle diffusion through a time series of micrographs and particle count by a count of imaged particles. The number of observed particles imaged is controlled by the scattering cross-section of the particles and by camera settings such as sensitivity and shutter speed. Appropriate camera settings are defined as those that image, track, and analyze a sufficient number of particles for statistical repeatability.

View Article and Find Full Text PDF

An accurate assessment of particle characteristics and concentrations in pharmaceutical products by flow imaging requires accurate particle sizing and morphological analysis. Analysis of images begins with the definition of particle boundaries. Commonly a single threshold defines the level for a pixel in the image to be included in the detection of particles, but depending on the threshold level, this results in either missing translucent particles or oversizing of less transparent particles due to the halos and gradients in intensity near the particle boundaries.

View Article and Find Full Text PDF

Purpose: Industry and regulatory bodies desire more accurate methods for counting and characterizing particles. Measurements of proteinaceous-particle concentrations by light obscuration and flow imaging can differ by factors of ten or more.

Methods: We propose methods to correct the diameters reported by light obscuration and flow imaging instruments.

View Article and Find Full Text PDF

The analysis of natural and otherwise complex samples is challenging and yields uncertainty about the accuracy and precision of measurements. Here we present a practical tool to assess relative accuracy among separation protocols for techniques using light scattering detection. Due to the highly non-linear relationship between particle size and the intensity of scattered light, a few large particles may obfuscate greater numbers of small particles.

View Article and Find Full Text PDF

Measurement and characterization of subvisible particles (defined here as those ranging in size from 2 to 100 μm), including proteinaceous and nonproteinaceous particles, is an important part of every stage of protein therapeutic development. The tools used and the ways in which the information generated is applied depends on the particular product development stage, the amount of material, and the time available for the analysis. In order to compare results across laboratories and products, it is important to harmonize nomenclature, experimental protocols, data analysis, and interpretation.

View Article and Find Full Text PDF

Particle analysis tools for the subvisible (<100 μm) size range, such as light obscuration, flow imaging (FI), and electrical sensing zone (ESZ), often produce results that do not agree with one another, despite their general agreement when characterizing polystyrene latex spheres of different sizes. To include the effect of shape in comparison studies, we have used the methods of photolithography to create rods and disks. Although the rods are highly monodisperse, the instruments produce broadened peaks and report mean size parameters that are different for different instruments.

View Article and Find Full Text PDF

Accurate counting and sizing of protein particles has been limited by discrepancies of counts obtained by different methods. To understand the bias and repeatability of techniques in common use in the biopharmaceutical community, the National Institute of Standards and Technology has conducted an interlaboratory comparison for sizing and counting subvisible particles from 1 to 25 μm. Twenty-three laboratories from industry, government, and academic institutions participated.

View Article and Find Full Text PDF

In this paper, we demonstrate the use of 2-pyridinemethanol (2P) aqueous solutions as a refractive index matching liquid. The high refractive index and low viscosity of 2P-water mixtures enables refractive index matching of beads that cannot be index matched with glycerol-water or sucrose-water solutions, such as silica beads that have the refractive index of bulk fused silica or of polymethylmethacrylate beads. Suspensions of beads in a nearly index-matching liquid are a useful tool to understand the response of particle counting instruments to particles of low optical contrast, such as aggregated protein particles.

View Article and Find Full Text PDF

All therapeutic protein products contain intrinsic particles formed by the aggregation of protein monomers. There is growing interest in understanding particles in biopharmaceutical products, fostered on one hand by significant advancements in particle analysis and on the other hand by concerns about potential impact of particles on product quality and safety. With currently available methods, particles in therapeutic proteins can be counted, sized, and characterized in a rudimentary way over a broad size range (from 10s of nanometers to 100 s of micrometers).

View Article and Find Full Text PDF

We report the characterization of gold nanoparticles modified with thiol-terminated single stranded DNA (ssDNA) using analytical ultracentrifugation. Dynamic light scattering was used to measure the diameter of bare and ssDNA modified gold nanoparticles to corroborate the predictions of our models. Sedimentation coefficients of nominally 10 and 20 nm diameter gold nanoparticles modified with thiol-terminated thymidine homo-oligonucleotides, 5-30 bases in length, were determined with analytical ultracentrifugation.

View Article and Find Full Text PDF