Publications by authors named "DeSong Zhan"

The present study aimed to assess the bond strength and durability of six bonding agents concerning their application to metal or ceramic brackets and zirconia. Six resin cement bonding agents (XT, XTS, RSBU, RGBU, SBPM, and GMP) were chosen for this investigation. Specimens were either stored in distilled water at 37°C for 24 h or subjected to 5,000 thermocycles before conducting a Shear Bond Strength (SBS) test.

View Article and Find Full Text PDF

is the most common species that causes peri-implantitis. It forms an irreversible dense biofilm and causes inflammation. A novel 3D-printed porous TC4-6Cu alloy was fabricated using selective laser melting (SLM) technology for the dental implant, which is anticipated to inhibit biofilm formation.

View Article and Find Full Text PDF

Objectives: This study aims to evaluate the color stability and related properties including water sorption and solubility of ten light-cured composite resins in different solutions.

Methods: A total of 10 composite resins were BeautifilⅡ(B2) and Ceram. X One Universal (CXU), Charisma (CS), Charisma Diamond (CD), Denfil (DF), DX.

View Article and Find Full Text PDF

This study aims to assess the color stability, water sorption, and solubility of 11 resin composites as commercially available dental products. Twenty samples (10 mm in diameter and 2 mm in thickness) of each material were fabricated using a customized silicone mold, followed by immersion in each of curry, coffee, wine, and distilled water for 28 days (n = 5). Baseline shade and color changes (ΔE) were measured using a reflection spectrophotometer.

View Article and Find Full Text PDF

This study aimed to evaluate the shear bond strength (SBS) of four bonding agents used to bond metal brackets to zirconia under different storage conditions. Four bonding agents were used [FLC: (Fuji ORTHO LC), XT: (Transbond XT), RUC-SBU: (Rely X Ultimate Clicker Adhesive Resin Cement+Single Bond Universal), and RUC-GBU: (Rely X Ultimate Clicker Adhesive Resin Cement+Gluma Bond Universal)] to bond two types of metal brackets (PT/3M) to zirconia surfaces, and they were stored in water at 37ºC for 24 h or thermocycling for 3,000 cycles. The SBS data of RUC-SBU and RUC-GBU using PT brackets were significantly higher than those of 3M brackets before and after thermocycling.

View Article and Find Full Text PDF

Orthopedic hybrid implants combining both titanium (Ti) and magnesium (Mg) have gained wide attraction nowadays. However, it still remains a huge challenge in the fabrication of Mg-Ti composites because of the different temperatures of Ti melting point and pure Mg volatilization point. In this study, we successfully fabricated a new Mg-Ti composite with bi-continuous interpenetrating phase architecture by infiltrating Mg melt into Ti scaffolds, which were prepared by 3D printing and subsequent acid treatment.

View Article and Find Full Text PDF

Objective: To assess the clinical status of monolithic zirconia CAD/CAM endocrowns and crowns on post and core buildups in endodontically treated molars after 5 years of clinical service.

Materials And Methods: A total of 670 patients who received restorations for excessive defects at Ansteel Group Hospital from 2012 to 2015 were selected and randomly divided into two groups: 334 patients in the endocrown group and 336 in the post and core crown group. All the treatments were performed using a digital CAD/CAM system.

View Article and Find Full Text PDF

c‑mesenchymal‑epithelial transition (Met) is a transmembrane tyrosine kinase receptor of hepatocyte growth factor (HGF). HGF/Met signaling stimulates numerous pathways, including the Ras/mitogenactivated protein kinase (MAPK), phosphatidylinositol 3‑kinase/protein kinase B and Wnt/β‑catenin pathways, which serve important roles in cell proliferation, survival, motility, invasion and angiogenesis, and promotes the development and progression of tumors. Aberrant HGF/Met signaling is associated with a poor prognosis in several types of tumors, including head and neck squamous cell carcinoma (HNSCC).

View Article and Find Full Text PDF

Objective: This study aimed to compare the effects of water storage treatment and thermal cycling on the shear bond strength (SBS) of three self-adhesive dual-cure resin cements.

Methods: Six cubic zirconia specimens with side length of 2 cm were obtained by cutting and sintering. Three self-adhering dual-cure resin cements (i.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the air-blowing temperature and water storage time on the micro-tensile bond strength (μTBS) of five universal adhesive systems to dentin. The bond strength with two different air-blowing temperatures (60±2ºC and 23±2ºC) was measured after water storage at 37ºC for 24 h and 100 days respectively. The fracture surface on dentin side was observed by scanning electron microscope (SEM).

View Article and Find Full Text PDF

Objective: This study aimed to determine the effects of copper content on the corrosion resistance of CoCrMoCu alloy and its in vitro antibacterial performance.

Methods: CoCrMoCu specimens with different Cu contents (2%, 3%, 5%, and 7%) were prepared by vacuum melting method. CoCrMo without Cu served as control.

View Article and Find Full Text PDF

The Eysenck Personality Questionnaire's (EPQ) N value (neuroticism) was used to evaluate information from 158 patients before ceramic crown treatment. Patient satisfaction was also evaluated using a satisfaction questionnaire 2 weeks post treatment. Patient expectations were not correlated with sex, age, or N value, and sex was not correlated with patient satisfaction other than in relation to crown shape.

View Article and Find Full Text PDF

Background/aim: Difficulties in the acceptance of dentures are multifactorial including psychosocial ones. It is questionable whether the patients' satisfaction depends only on the complete denture therapy characteristics. The aim of the study was to evaluated patients' expectation and satisfaction with complete dentures before and after the treatment concerning phonetics, chewing, comfort of use and aesthetics.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the impact of psychological intervention on edentulous patients' satisfaction with complete clinically satisfactory complete dentures. The survey was conducted in China Medical University involving 84 individuals receiving complete dentures at this institution from August 2013 to March 2014. Participants were randomly allocated to intervention and control groups consisting of 42 subjects, respectively.

View Article and Find Full Text PDF

Objective: To compare the shear bond strength(SBS) of cast Co-Cr alloys and selective laser melting(SLM) Co-Cr alloys with those of dental porcelain.

Methods: A dental porcelain (Vita) was applied on cast and SLM Co-Cr alloy specimens (n = 10). SBS test was conducted, and fracture mode analysis was determined.

View Article and Find Full Text PDF

Objective: To compare curative effect between complete denture with lingualized occlusion and anatomic occlusion on temporomandibular joint disorders (TMD) of aged edentulous patients with severe residual alveolar ridge resorption.

Methods: Seventy aged edentulous patients with severe residual alveolar ridge resorption were recruited in this study and randomly assigned into two groups, thirty-five each. In Group A, patients received complete denture with lingualized occlusion, and in Group B, patients received complete denture with anatomic occlusion.

View Article and Find Full Text PDF

Objective: To evaluate the metal-ceramic bond strength of a selective laser melting Co-Cr alloy.

Methods: Twelve Co-Cr metal bars were prepared according to the ISO 9693 standard with Vita porcelain fused onto the centre of each bar. Then the sample bars were divided into two groups of six each.

View Article and Find Full Text PDF

Objective: To study the color reappearance effect of metal-ceram restoration and foundry-ceram restoration using Crystaleye spectrophotometer.

Methods: 58 metal-ceram restorations and 58 foundry-ceram restorations according to the result of the Crystaleye spectrophotometer were made respectively. The deltaE between restorations and natural teeth as referenced were analyzed.

View Article and Find Full Text PDF

Objective: To investigate effects of the leaching liquids of 5 different kinds of dental alloys on L929 cells at cell level and molecular level.

Methods: The fibroblast L929 cells of mouse were cultivated in vitro in leaching liquids of 5 different kinds of dental alloys, Au alloy (n = 8), Ag-Pt alloy (n = 8), Co-Cr alloy (n = 8), Ni-Cr alloy (n = 8), and Cu alloy (n = 8). The RPMI 1640 cell medium containing 10% fetal beef serum was used as control.

View Article and Find Full Text PDF

Objective: To study the bonding capability when Ni-Cr porcelain alloy was added with Ti, compound rare earth metals and removed the element of Be.

Methods: Ni-Cr-Ti porcelain alloys manufactured by Institute of Metal Research of Chinese Academy of Sciences were tested. The test alloys were divided into three groups according to whether containing Be and compound rare earth metals or not.

View Article and Find Full Text PDF

Objective: Titanium, by far one of the oldest materials in medical implants used for hard tissue replacement and rehabilitation, was used widely as implant material. The objective of the present study was to fabricate the TiN modified layer on the surface of medical pure titanium and improve its surface properties. Thus the wear resistance, biocompatibility and antisepsis were improved.

View Article and Find Full Text PDF

Objective: This study was intended to design a kind of resisting part dint of device in order to preventing the base plate break while being subjected to the dint when partial base plate dint concentrates because of the increase of the magnetic attachment to the original movable artificial teeth.

Methods: Ten patients who should increase magnetic attachment was adopted in the study, and we increased a kind of new designed partial cast base plate on the original base plate using laser welding technique, then designed magnetic attachment and artificial teeth.

Results: None of ten sufferers appeared the phenomenon of the break of the base plate.

View Article and Find Full Text PDF