Purpose: The aim of this study is to assess multi-center reproducibility and longitudinal consistency of MRI imaging measurements, as part of a phase III longitudinal multi-center study comparing the neurotoxic effect following prophylactic cranial irradiation with hippocampal avoidance (HA-PCI), in comparison with conventional PCI in patients with small-cell lung cancer.
Methods: Harmonized MRI acquisition protocols from six participating sites and two different vendors were compared using both physical and human phantoms. We assessed variability across sites and time points by evaluating various phantoms and data including hippocampal volume, diffusion metrics, and resting-state fMRI, from two healthy volunteers.
Radiotherapy (RT) plays a major role in the curative treatment of locally advanced non-small cell lung cancer (NSCLC). Therefore, the ACROP committee was asked by the ESTRO to provide recommendations on target volume delineation for standard clinical scenarios in definitive (chemo)radiotherapy (RT) and adjuvant RT for locally advanced NSCLC. The guidelines given here are a result of the evaluation of a structured questionnaire followed by a consensus discussion, voting and writing procedure within the committee.
View Article and Find Full Text PDFEekers et al. have recently proposed a neuro-oncology atlas, which was co-authored by most centers associated in the European Proton Therapy Network (EPTN; Figure 1). With the introduction of new treatment techniques, such as integrated magnetic resonance imaging and linear accelerators (MR-linac) or particle therapy, the prediction of clinical efficacy of these more costly treatment modalities becomes more relevant.
View Article and Find Full Text PDFPurpose: To create a digital, online atlas for organs at risk (OAR) delineation in neuro-oncology based on high-quality computed tomography (CT) and magnetic resonance (MR) imaging.
Methods: CT and 3 Tesla (3T) MR images (slice thickness 1 mm with intravenous contrast agent) were obtained from the same patient and subsequently fused. In addition, a 7T MR without intravenous contrast agent was obtained from a healthy volunteer.
Purpose: To compare dose to organs at risk (OARs) and dose-escalation possibility for 24 stage I non-small cell lung cancer (NSCLC) patients in a ROCOCO (Radiation Oncology Collaborative Comparison) trial.
Methods: For each patient, 3 photon plans [Intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and CyberKnife], a double scattered proton (DSP) and an intensity-modulated carbon-ion (IMIT) therapy plan were created. Dose prescription was 60 Gy (equivalent) in 8 fractions.
Objectives: Current guidelines recommend preoperative invasive mediastinal staging in centrally located tumours with negative mediastinum on positron emission tomography-computed tomography, based on a 20-30% prevalence of occult mediastinal disease (pN2-3). However, a uniform definition of central tumour location is lacking. Our objective was to determine the best definition in predicting occult pN2-3.
View Article and Find Full Text PDFStereotactic ablative body radiotherapy (SABR) is popular because of the high rates of local control with low toxicity seen in lung cancer patients. In this study we compared clinically significant toxicity and overall survival for SABR and non-SABR definitive radiotherapy (conformal radiotherapy) patients. A PUBMED search of all human, English language articles on SABR and non-SABR radically treated early stage lung cancer patients was performed until June 2016.
View Article and Find Full Text PDFTransl Lung Cancer Res
December 2017
Both tumors and patients are complex and models that determine survival and toxicity of radiotherapy or any other treatment ideally must take into account this variability as well as its dynamic state. The genetic features of the tumor and the host, and increasingly also the epi-genetic and proteomic characteristics, are being unraveled. Multiple techniques, including histological examination, blood sampling, measurement of circulating tumor cells (CTCs), and functional and molecular imaging, can be used for this purpose.
View Article and Find Full Text PDFBackground And Purpose: We aimed to identify tumour subregions with characteristic phenotypes based on pre-treatment multi-parametric functional imaging and correlate these subregions to treatment outcome. The subregions were created using imaging of metabolic activity (FDG-PET/CT), hypoxia (HX4-PET/CT) and tumour vasculature (DCE-CT).
Materials And Methods: 36 non-small cell lung cancer (NSCLC) patients underwent functional imaging prior to radical radiotherapy.
Int J Technol Assess Health Care
January 2017
Introduction: Optimizing radiotherapy with or without chemotherapy through advanced imaging and accelerated radiation schemes shows promising results in locally advanced non-small-cell lung cancer (NSCLC). This study compared the cost-effectiveness of positron emission tomography-computed tomography based isotoxic accelerated sequential chemo-radiation (SRT2) and concurrent chemo-radiation with daily low-dose cisplatin (CRT2) with standard sequential (SRT1) and concurrent chemo-radiation (CRT1).
Methods: We used an externally validated mathematical model to simulate the four treatment strategies.
Background: Early death after a treatment can be seen as a therapeutic failure. Accurate prediction of patients at risk for early mortality is crucial to avoid unnecessary harm and reducing costs. The goal of our work is two-fold: first, to evaluate the performance of a previously published model for early death in our cohorts.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
October 2017
Purpose: Tools for survival prediction for non-small cell lung cancer (NSCLC) patients treated with chemoradiation or radiation therapy are of limited quality. In this work, we developed a predictive model of survival at 2 years. The model is based on a large volume of historical patient data and serves as a proof of concept to demonstrate the distributed learning approach.
View Article and Find Full Text PDFAim: To investigate whether breast cancer patients' visits to an outpatient clinic for late outcome (OCLO) can be replaced by patient reported outcome measures (PROMs), by comparing late toxicity scored at the OCLO with PROMs.
Methods: All breast cancer patients treated in our institute with adjuvant radiotherapy 10-11years ago were invited to visit the OCLO, and for filling out PROM-questionnaires. Concordance rate between PROMs and OCLO-reported outcome and the percentage of patients with ≥2 degrees difference in toxicity level between patient and clinician was assessed.
Background: Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant.
View Article and Find Full Text PDFObjective: To analyse how often innovations in healthcare are evaluated regarding output, especially in radiotherapy. Output was defined as either survival, toxicity, safety, service, efficiency or cost-effectiveness.
Methods: A systematic literature review was conducted, using three search strategies: (1) innovations in general healthcare; (2) radiotherapy-specific innovations, i.
Aims: Concurrent chemoradiotherapy (CCRT) is considered the standard treatment regimen in non-surgical locally advanced non-small cell lung cancer (NSCLC) patients and sequential chemoradiotherapy (SCRT) is recommended in patients who are unfit to receive CCRT or when the treatment volume is considered too large. In this study, we investigated the proportion of CCRT/SCRT in the Netherlands and Belgium. Furthermore, patient and disease characteristics associated with SCRT were assessed.
View Article and Find Full Text PDFBackground: Nintedanib has anti-fibrotic and anti-inflammatory activity and is approved for the treatment of idiopathic pulmonary fibrosis. The aim of this study was to noninvasively assess the efficacy of nintedanib in a mouse model of partial lung irradiation to prevent radiation-induced lung damage (RILD).
Methods: 266 C57BL/6 adult male mice were irradiated with a single radiation dose (0, 4, 8, 12, 16 or 20Gy) using parallel-opposed fields targeting the upper right lung using a precision image-guided small animal irradiator sparing heart and spine based on micro-CT images.
Purpose: To update literature-based recommendations for techniques used in high-precision thoracic radiotherapy for lung cancer, in both routine practice and clinical trials.
Methods: A literature search was performed to identify published articles that were considered clinically relevant and practical to use. Recommendations were categorised under the following headings: patient positioning and immobilisation, Tumour and nodal changes, CT and FDG-PET imaging, target volumes definition, radiotherapy treatment planning and treatment delivery.
The advent of immunotherapy is currently revolutionizing the field of oncology, where different drugs are used to stimulate different steps in a failing cancer immune response chain. This review gives a basic overview of the immune response against cancer, as well as the historical and current evidence on the interaction of radiotherapy with the immune system and the different forms of immunotherapy. Furthermore the review elaborates on the many open questions on how to exploit this interaction to the full extent in clinical practice.
View Article and Find Full Text PDF