Objective: this study sought to evaluate the effect of isobornyl methacrylate (IBOMA) as a diluent monomer on the physicochemical properties of experimental flowable resin composites.
Methodology: the organic resin matrix of a modal flowable resin composite was formulated with 50 wt.% of bisphenol-A-glycidyl methacrylate (Bis-GMA) and 50 wt.
The emergence profile in implant restoration has an important contribution to the final esthetic result. Moreover, a properly shaped emergence profile enables well-performed dental hygiene and protects the implant-restoration complex from peri-implant infections. This report describes a clinical case that combines digital workflow and designing with a custom implant healing abutment system (Cervico).
View Article and Find Full Text PDFBackground: To evaluate the thermal insulation of protective liners and glass ionomer cement during light-curing procedures.
Material And Methods: Human third molars underwent Class I preparations with dimensions 5 mm long × 4 mm wide × 4 mm deep in a standardized manner ensured a consistent ±0.5 mm dentin thickness at the pulpal floor.
The present study examined different concentrations of the butylated hydroxytoluene (BHT) inhibitor on the kinetics of conversion, polymerization shrinkage stress, and other correlated physicochemical properties of experimental resin composites (ERC). A model composite was formulated with 75 wt% filler containing 0.5 wt% camphorquinone and 1 wt% amine with BHT concentrations of 0.
View Article and Find Full Text PDFObjective: To determine the best indicator of mobility decline between dynapenia, low skeletal muscle mass index (SMMI), and sarcopenia defined by the EWGSOP2 using different cutoff points for grip strength.
Methods: A longitudinal study was conducted with a follow-up of eight years, involving 2,680 individuals aged 60 and older who participated in the ELSA study with a walking speed greater than 0.8 m/s at baseline.
Objectives: To evaluate the compressive modulus, translucency, and light curing irradiance transmittance of four clear polyvinyl siloxane (PVS) materials used for the injection molding technique at varying thicknesses, and to assess the correlation between color parameters and irradiance transmittance.
Materials And Methods: Four clear PVS materials (Exaclear, Clear Bite Matrix, Affinity Crystal, and Memosil 2) were used in this study. Compressive modulus was measured by compressing cylindrical PVS specimens (n = 9; d = 10 mm; t = 6 mm) up to 30% strain using a universal testing machine.
J Gerontol A Biol Sci Med Sci
July 2024
Background: We aimed to analyze the trajectories of cognitive decline as a function of the presence of type 2 diabetes and glycemic control in analyzes stratified by sex in an 8-year follow-up period.
Methods: A total of 1 752 men and 2 232 women aged ≥50 years who participated in the English Longitudinal Study of Ageing (ELSA), conducted from 2004 to 2012, were analyzed. The outcomes of interest were performance on the cognitive domains of memory, executive function, and temporal orientation as well as the global cognition score.
Aim: Although diabetes is a risk factor for walking speed decline in older adults, it remains unclear how glycaemic control [assessed by glycated haemoglobin (HbA1c)] might affect the long-term trajectories of walking speed. We investigated whether the glycaemic control status accelerates the walking speed decline and whether this decline differs depending on previous mobility conditions.
Materials And Methods: In total, 3202 individuals aged ≥60 years from the English Longitudinal Study of Ageing (ELSA) were classified at baseline and after 4 and 8 years of follow-up according to glycaemic control status as 'without diabetes' (no self-reported diabetes and HbA1c <6.
Purpose: The purpose of this study was to evaluate the flexural strength (FS), flexural modulus (FM), and fatigue limit (FL) of 3D-printed resin-based polymers and composites and compare them to 3D-printed composites.
Materials And Methods: A bar-shaped specimen (25 × 2 × 2 mm) was CAD designed according to ISO 4049:2019, and 60 duplicates of the 3D model were nested at a 45-degree angle with the printing platform and 3D-printed with three materials: denture teeth resin (Denture Teeth, Formlabs), temporary crown and bridge resin (Temporary CB, Formlabs), and composite (Flexcera Smile Ultra+, Desktop Health). The 3D model was also imported into a dental CAM software, duplicated 60 times, nested, and milled from a 3D-milled composite puck (Ivotion Denture Teeth, Ivoclar).
This study aimed to evaluate the effect of an elastomeric urethane monomer (Exothane-24) in different concentrations on physicochemical properties, gap formation, and polymerization shrinkage stress of experimental resin composites. All experimental composites were prepared with 50 wt.% of Bis-GMA and 50 wt.
View Article and Find Full Text PDF(Group B , GBS) is the leading cause of neonatal sepsis and meningitis but has been recently isolated from non-pregnant adults with underlying medical conditions like diabetes. Despite diabetes being a key risk factor for invasive disease, the pathological consequences during GBS infection remain poorly characterized. Here, we demonstrate the pathogenicity of the GBS90356-ST17 and COH1-ST17 strains in streptozotocin-induced diabetic mice.
View Article and Find Full Text PDFThe aim was to evaluate the marginal-gap formation and curing profile of a new restorative technique using a liner with long-wavelength-absorbing photoinitiator (LWAP). Box-shaped preparations (6 mm × 4 mm × 4 mm) were made in third molars. All samples were treated with Clearfill SE Bond and divided into 4 groups (n = 5), according to restorative technique used: (1) incremental technique (INC-Technique); (2) camphorquinone-based liner (CQ-Liner) + bulk-fill resin composite; (3) LWAP-based liner (LWAP-Liner) + bulk-fill resin composite; and (4) bulk-fill technique without liner (BF-Technique).
View Article and Find Full Text PDFThis article compares the accuracy of intraoral scanners (IOSs) used in the digital impression of full arches to fabricate implant-supported complete prostheses. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and was registered in the Open Science Framework (DOI 10.17605/OSF.
View Article and Find Full Text PDFBackground: Dynapenic abdominal obesity has been shown as a risk factor for all-cause mortality in older adults. However, there is no evidence on the association between this condition and cardiovascular mortality.
Objective: We aimed to investigate whether dynapenic abdominal obesity is associated with cardiovascular mortality in individuals aged 50 and older.
Objectives: The aim of this study was to evaluate the accuracy of machine learning regression models in predicting the final color of leucite-reinforced glass CAD/CAM ceramic veneer restorations based on substrate shade, ceramic shade, thickness and translucency.
Methods: Leucite-reinforced glass ceramics in four different shades were sectioned in thicknesses of 0.3, 0.
Background/objective: The mechanisms, risk factors and influence of sex on the incidence of frailty components are not fully understood. The aim of this study was to analyse sex differences in factors associated with the increase in the number of frailty components.
Methods: A 12-year follow-up analysis was conducted with 1,747 participants aged ≥ 60 of the ELSA Study with no frailty at baseline.
To examine, by gender, the relationship between adverse events in childhood or adolescence and the increased risk of early mortality (before 80 years). The study sample included 941 participants of the English Longitudinal Study of Aging who died between 2007 and 2018. Data on socioeconomic status, infectious diseases, and parental stress in childhood or adolescence were collected at baseline (2006).
View Article and Find Full Text PDFBackground: Intraoral scanners (IOS) are gaining interest in Dentistry for their ability to capture digital impressions of the oral cavity. These digital impressions facilitate the fabrication of indirect restorations using CAD/CAM technology. This study aimed to describe an elective course given to predoctoral dental students on the topic of Digital Dentistry and assess their learning outcomes and system preferences.
View Article and Find Full Text PDFThis article focuses on the current understanding and concerns over the blue-light hazard when using dental light-curing units. It also provides information and safety protocols to guide the practitioner in making important decisions regarding dental personnel's health and the quality of dental restorations.
View Article and Find Full Text PDFThe World Health Organization indicates that more than 1.5 billion people are infected with geohelminths. Soil-transmitted helminths prevail mostly in tropical and subtropical regions, in areas with inadequate hygiene and sanitation conditions, and basic health education problems.
View Article and Find Full Text PDFCalcif Tissue Int
December 2022
Epidemiological evidence showing the association between low 25(OH)D and age-related reduction in neuromuscular strength (dynapenia) is a paucity and controversial and, to date, the effect of osteoporosis and vitamin D supplementation on these associations has not been measured. Thus, we analyze whether serum 25(OH)D deficiency and insufficiency are risk factors for the incidence of dynapenia in individuals aged 50 or older and whether osteoporosis or vitamin D supplementation modify these associations. For that, 3205 participants of the ELSA study who were non-dynapenic at baseline were followed for 4 years.
View Article and Find Full Text PDFBackground: The purpose of this in vitro study was to evaluate the color difference between the Vita Classical Shade Guide and composite veneers using the dual-layer technique.
Material And Methods: Thirty samples were fabricated using a custom-made mold (Easy Layering Shade Guide Kit, 3M) using two resin composites: Filtek Supreme Ultra (3M); and Estelite Omega (Tokuyama) (n=3). The composite veneers were made by layering the different enamel and body or dentin shades from each composite.
Background: To evaluate the intra-pulpal temperature during different direct pulp capping methods and light-cured procedures.
Material And Methods: Class I preparations 5 mm long, 4 mm wide and 4 mm deep were performed in extracted third molars, leaving 0.5 mm of dentin at the pulpal floor with a 1 mm diameter of pulp exposure.
Background: The use of dental headlights is a common practice to better illuminate the operatory field and achieve excellence in restorative dentistry. However, visible light-cured dental materials can have reduced working time under headlight illumination. The aim of this study was to evaluate the influence of the spectral irradiance power of two dental headlights on the degree of polymerization and working time of light-curable dental composites.
View Article and Find Full Text PDFThis study aimed to evaluate the effect of light attenuation through ceramic veneers and resin cement on degree of conversion (DC), cohesive strength (CS), and microshear bond strength (μSBS) of experimental adhesive systems. Experimental etch-and-rinse and self-etch adhesives were combined with different ratios of camphorquinone (CQ) and diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO) photoinitiators: CQ-only; 3CQ:1TPO; 1CQ:1TPO; 1CQ:3TPO and TPO-only. Square-shaped ceramic veneer (IPS Empress Esthetic, Ivoclar Vivadent) (n = 10; 10mm long x 10mm wide x 0.
View Article and Find Full Text PDF