Unlabelled: Nowadays, aligners represent a possible therapeutical approach that combines both esthetic and function in order to address dental malocclusion. However, they require a significant level of compliance from the patient. According to the manufacturer, at least 22 h of wearing a day is demanded to reach the optimal therapeutical level; hence, aligners can only be removed during meals.
View Article and Find Full Text PDFThe goal was to evaluate the efficacy of the sausage technique in reconstructing the crestal buccal bone thickness, focusing on the distribution shape of the regenerated volume. Ten implants were placed in five patients with Cawood-Howell class IV defects. A cone beam computed tomography (CBCT) was executed at T0 (before surgery).
View Article and Find Full Text PDFBroken screw removal from the implant connection is a common but challenging process. Several proposed methods and technical solutions may result in unsuccessful removal; thus, a novel, more conservative, risk-free method is proposed as a first attempt. The proposal is to use a silicon restoration holder to be twisted counterclockwise on the dried surface of the broken fragment inside the implant connection.
View Article and Find Full Text PDFBackground: Periodontal disease is a common infectious disease that leads to the destruction of tooth-supporting structures. Current treatments, such as scaling and root planing (SRP), have limitations in deep and complex pockets, and antibiotic use carries the risk of resistance. Sterify Gel, a medical device composed of polyvinyl polymers, hydroxytyrosol, nisin, and magnesium ascorbyl phosphate, offers a new approach to periodontal care.
View Article and Find Full Text PDFPeri-implant disease and its treatment is becoming a major concern for clinicians as the number of implants placed each year is rising. Smoking is a common habit, and it is associated with an increased risk of developing peri-implant disease. The role of smoking in the response to peri-implant treatment has never been investigated.
View Article and Find Full Text PDFThe study aims to investigate the modifications in the temporalis and the masseter activity in adult patients before and after SARPE (Surgically Assisted Rapid Palatal Expansion) by measuring electromyographic and electrokinesographic activity. 24 adult patients with unilateral posterior crossbite on the right side were selected from the Orthodontic Department of the University of Milan. Three electromyographic and electrokinesographic surface readings were taken respectively before surgery (T0) and 8 months after surgery (T1).
View Article and Find Full Text PDFThe success of surgical procedures is strictly related to the biomechanical properties of the suture. Mechanical comparisons are scarcely reported in the literature, so the purpose of the present study was to evaluate and compare the mechanical behavior of different sutures commonly used in oral surgery in terms of traction resistance. Sutures made of eight different materials were analyzed: silk (S), polyglycolide-co-caprolactone (PGCL), polypropylene (PP), rapid polyglycolide (rPGA), standard polyglycolide (PGA), polyamide (PA), polyester (PE), and polyvinylidene fluoride (PVDF).
View Article and Find Full Text PDFTo verify the influence of platform-switching (PS) on soft tissue behavior by comparing the soft tissue stability around implants with and without PS, during three years of follow-up. The study included patients treated with fixed dentures supported by implants with an internal connection. The radiographic distance between the first bone-to-implant contact (FBIC) and the implant shoulder was assessed.
View Article and Find Full Text PDFImpression accuracy is fundamental to achieve a passive fit between implants and the superstructure. Three transfer types were tested to evaluate the differences in impression accuracy and their efficiency in case of different implant angles. A master model with four implant analogues placed at 0°, 15° and 35° was used.
View Article and Find Full Text PDF(1) Background: The purpose of the present study was to retrospectively evaluate and compare the outcome of two sinus augmentation grafting protocols using a xenograft or blood clot alone over a 72-month follow-up. (2) Methods: Patients who received simultaneous lateral sinus floor augmentation and implant placement were included. Subjects were divided into two groups according to the grafting material, namely xenograft or blood clot, and into sub-groups based on the residual alveolar bone height (RABH) below the maxillary sinus, namely 4 to 6 mm or >6 mm.
View Article and Find Full Text PDFInt J Environ Res Public Health
September 2020
The aim of this study was to evaluate the influence of bone quality, drilling technique, implant diameter, and implant length on insertion torque (IT) and resonance frequency analysis (RFA) of a prototype-tapered implant with knife-edge threads. The investigators hypothesized that IT would be affected by variations in bone quality and drilling protocol, whereas RFA would be less influenced by such variables. The investigators implemented an in vitro experiment in which a prototype implant was inserted with different testing conditions into rigid polyurethane foam blocks.
View Article and Find Full Text PDFBMC Oral Health
February 2020
Background: To compare tissue response to two implant systems, featuring internal hexed connections with different designs.
Methods: Patients enrolled in this randomized controlled trial were assigned to two groups. In Group 1, patients were treated with implants with a 5° conical internal hexed connection (Anyridge®, MegaGen, South Korea).
Background: Optimal aesthetic implant restoration is a combination of a visually pleasing prosthesis and adequate surrounding peri-implant soft tissue architecture. This study describes the influence of the residual buccal bone thickness (BBT), measured at the time of implant placement, on the soft tissue maturation during three years of follow-up.
Methods: Seventy-eight implants were enrolled in the present study.
Masticatory overload on dental implants is one of the causes of marginal bone resorption. The implant-abutment connection (IAC) design plays a critical role in the quality of the stress distribution, and, over the years, different designs were proposed. This study aimed to assess the mechanical behavior of three different types of IAC using a finite element model (FEM) analysis.
View Article and Find Full Text PDFBackground: The aim of the present systematic review was to screen the literature and to describe current applications of augmented reality.
Materials And Methods: The protocol design was structured according to PRISMA-P guidelines and registered in PROSPERO. A review of the following databases was carried out: Medline, Ovid, Embase, Cochrane Library, Google Scholar and the Gray literature.
Background: Previous studies have suggested that mucosal height is related to the bone level and soft tissue thickness. The purpose of this pilot study was to investigate the ratio between the height and width of the tissues around single implants with a conical connection and platform switching.
Methods: All patients receiving single implants (Anyridge, MegaGen, Gyeongbuk, South Korea) and restored with single crowns, in a three-month period, were included in this study.
Bisphosphonates (BPs) represent the first-line treatment for a wide array of bone disorders. Despite their well-known action on osteoclasts, the effects they induce on osteoblasts are still unclear. In order to shed light on this aspect we evaluated the impact of two nitrogen containing bisphosphonates, Alendronate (ALN) and Zoledronate (ZOL), on human primary pre-osteoblasts.
View Article and Find Full Text PDFInt J Periodontics Restorative Dent
February 2019
The aim of this study was to evaluate different cleaning procedures for customized laser-microtextured titanium abutments. A total of 20 customized laser-microtextured abutments were randomized into four groups: no cleaning (control group), ultrasonic treatments + autoclave cycle (group 1), ultrasonic treatments + argon plasma (group 2), and only argon plasma (group 3). Surface contaminants were assessed through scanning electron microscopy and energy-dispersive x-ray spectroscopy microanalysis.
View Article and Find Full Text PDFInt J Periodontics Restorative Dent
September 2018
This report describes a failed blade implant after 25 years in function in the left maxilla and the results of histologic analysis of peri-implant tissues. The blade was retrieved, and histologic findings revealed that it was not osseointegrated despite being successfully in function for so many years. The long-term function of blade implants without osseointegration can be attributed to biotolerance exhibited by the implant rather than actual osseointegration.
View Article and Find Full Text PDFThe human dental follicle (hDF) contains the developing tooth and is involved in regulating tooth maturation and eruption. To investigate the mesenchymal stromal cells of the dental follicle, 2 three-dimensional (3D) culture models were used, based on a dynamic bioreactor: the Rotary Cell Culture System (RCCS™) and the 3D culture of precursor cells isolated from follicular tissue (human dental follicle cells [hDFCs]). The hDFCs were obtained from impacted third molars of 20 patients.
View Article and Find Full Text PDFHuman mesenchymal stromal cells (MSCs) have been widely investigated both for regenerative medicine and their antinflammatory/immunomodulatory capacity. However, their ability to home pathological tissues suggested the development of strategies for using MSCs as carrier to deliver drug into tumor microenvironment. MSCs obtained from different tissues can be loaded in vitro with anti-cancer drugs by a simple procedures.
View Article and Find Full Text PDFInt J Periodontics Restorative Dent
January 2017
The purpose of the present prospective randomized study was to evaluate the influence of Laser-Lok microtextured surface on soft tissue peri-implant parameters and esthetics around immediate, functionally loaded implants for single-tooth replacement in the esthetic zone. This study included 77 patients divided into two groups based on different implants used: the control group had BioHorizons tapered internal non-Laser-Lok-type implants (NLL; n = 39) and the test group had BioHorizons tapered internal Laser-Lok-type implants (LL; n = 39). Outcome measures were survival, radiographic marginal bone-level changes, soft tissue parameters, and esthetics.
View Article and Find Full Text PDFThe aim of the study is to evaluate the long term results of ribbond retainer after orthodontic treatment. One hundred and thirty patients who were orthodontically treated satisfied the inclusion criteria of having received a semipermanent retention were treated with FRC lingual retainers (Ribbond (®)). It was performed a follow up evaluation after 2 years average from the retainer application and any complication or failure was recorded.
View Article and Find Full Text PDF