Introduction: Racial disparities exist in maternal and neonatal care including breastfeeding (BF). The purpose of this study is to assess factors associated with BF success by race with a specific focus on pre-birth BF plan and time duration from birth until initiation of skin-to-skin contact and from birth to the first feed or breastfeed.

Methods: A database query of our electronic medical records was performed for all patients who had a vaginal delivery that met our study criteria.

View Article and Find Full Text PDF

After completion of training, anesthesiologists may have fewer opportunities to see how colleagues practice, and their breadth of case experiences may also diminish due to specialization. We created a web-based reporting system based on data extracted from electronic anesthesia records that allows practitioners to see how other clinicians practice in similar cases. One year after implementation, the system continues to be utilized by clinicians.

View Article and Find Full Text PDF

Background: Electrocardiography (ECG) electrodes require special expiration tracking after the manufacturer's packaging is opened. Compliance with this requirement, however, can be inconsistent. The authors tested the efficacy of a device that provides for expiration tracking of bulk-packaged electrodes to improve compliance.

View Article and Find Full Text PDF

Background: Visual analytics is the science of analytical reasoning supported by interactive visual interfaces called dashboards. In this report, we describe our experience addressing the challenges in visual analytics of anesthesia electronic health record (EHR) data using a commercially available business intelligence (BI) platform. As a primary outcome, we discuss some performance metrics of the dashboards, and as a secondary outcome, we outline some operational enhancements and financial savings associated with deploying the dashboards.

View Article and Find Full Text PDF

Electrocardiography electrodes have expiration dates that are foreshortened once the manufacturer's packaging is opened. A system is described for storing and dispensing these perishable electrodes while tracking their new expiration date for safety and regulatory purposes.

View Article and Find Full Text PDF

Background: Pulse oximetry is ubiquitous in anesthesia and is generally a reliable noninvasive measure of arterial oxygen saturation. Concerns regarding the impact of skin pigmentation and race/ethnicity on the accuracy of pulse oximeter accuracy exist. The authors hypothesized a greater prevalence of occult hypoxemia (arterial oxygen saturation [Sao2] less than 88% despite oxygen saturation measured by pulse oximetry [Spo2] greater than 92%) in patients undergoing anesthesia who self-reported a race/ethnicity other than White.

View Article and Find Full Text PDF

Background: Monitored Anesthesia Care (MAC) is an anesthetic service involving the titration of sedatives/analgesics to achieve varying levels of sedation while avoiding general anesthesia (GA) and airway instrumentation. The goal of our study was to determine the overall incidence of conversion from MAC to general anesthesia with airway instrumentation and elucidate reasons and risk factors for conversion.

Methods: In this retrospective observational study, all non-obstetric adult patients who received MAC from July 2002 to July 2015 at Mount Sinai Hospital were electronically screened for inclusion via a clinical database.

View Article and Find Full Text PDF

Background: Intra-operative hypothermia has been extensively investigated. However, the incidence of intra-operative hyperthermia has not been investigated in detail.

Objective: The main objective of this study was to assess the incidence and risk factors of new-onset intra-operative hyperthermia in a large surgical patient population.

View Article and Find Full Text PDF

Background: Intraoperative cardiac arrest (ICA) has a reported frequency of 1 in 10,000 anesthetics but has a much higher estimated incidence in orthotopic liver transplantation (OLT). Single-center studies of ICA in OLT are limited by small sample size that prohibits multivariable regression analysis of risks.

Methods: Utilizing data from 7 academic medical centers, we performed a retrospective, observational study of 5296 adult liver transplant recipients (18-80 years old) between 2000 and 2017 to identify the rate of ICA, associated risk factors, and outcomes.

View Article and Find Full Text PDF

Contamination of intravenous (IV) ports and stopcocks has been associated with postoperative infections. We tested the usability and efficacy of a novel passive shielding device to prevent such contamination even in the absence of hand hygiene or port disinfection. In a desktop setting with deliberately contaminated hands, qualitative port contamination was detected after 5/60 (8.

View Article and Find Full Text PDF

A 60-year-old woman with progressive dyspnea and cyanosis, O2-dependent pulmonary hypertension despite optimal medical therapy and remote atrial septostomy presented with worsening cyanosis and right-to-left shunting. The creation of a "fenestrated" ASD closure device with the insertion of a peripheral stent through an AMPLATZER™ ASD closure device was deployed to minimize right to left shunting and allow for enlargement of the shunt if needed. This case demonstrates the benefit of diminishing a right to left shunt with a self-fabricated fenestrated AMPLATZER device to improve symptoms in pulmonary hypertension patients with a pre-existing ASD.

View Article and Find Full Text PDF

The purpose of this study was to define the risk for adults with congenital heart disease who underwent cardiac catheterization and to propose a precatheterization risk scoring system. Data were prospectively collected using a multicenter registry of the Congenital Cardiovascular Interventional Study Consortium. The occurrence of serious adverse events (SAE) was correlated with 12 predefined variables.

View Article and Find Full Text PDF

During liver transplantation, the patient is at risk of developing progressive lactic acidosis. Following reperfusion, correction of acidosis may occur. In some patients, acidosis will worsen, a phenomenon referred to as persistent acidosis after reperfusion (PAAR).

View Article and Find Full Text PDF

Background: Anesthesia information management systems make prior anesthesia records readily available for review when patients return for a subsequent procedure but may create a problem of too much documentation to review in a limited amount of time. We implemented a screening tool to facilitate the identification of critical documentation for review.

Methods: An algorithm was developed to electronically search prior anesthesia records for predefined critical events and flag records containing these events.

View Article and Find Full Text PDF

Although minimally invasive repair of pectus excavatum has been shown to have a low complication rate in large series, several case reports have documented life-threatening complications, including bleeding and cardiac perforation. We present a rare case of an arteriovenous malformation from the internal thoracic artery to the pulmonary artery caused by occlusion of the internal thoracic artery by the Nuss bar followed by an unidentified angiogenic process. The patient became symptomatic and required transcatheter coil embolization.

View Article and Find Full Text PDF

Medical hardware and software device interoperability standards are not uniform. The result of this lack of standardization is that information available on clinical devices may not be readily or freely available for import into other systems for research, decision support, or other purposes. We developed a novel system to import discrete data from an anesthesia machine ventilator by capturing images of the graphical display screen and using image processing to extract the data with off-the-shelf hardware and open-source software.