Publications by authors named "David Politte"

Over the past several decades, dual-energy CT (DECT) imaging has seen significant advancements due to its ability to distinguish between materials. DECT statistical iterative reconstruction (SIR) has exhibited potential for noise reduction and enhanced accuracy. However, its slow convergence and substantial computational demands render the elapsed time for 3D DECT SIR often clinically unacceptable.

View Article and Find Full Text PDF

Dual-energy computed tomography (DECT) has been widely used to reconstruct numerous types of images due its ability to better discriminate tissue properties. Sequential scanning is a popular dual-energy data acquisition method as it requires no specialized hardware. However, patient motion between two sequential scans may lead to severe motion artifacts in DECT statistical iterative reconstructions (SIR) images.

View Article and Find Full Text PDF

Purpose: To assess the potential of a joint dual-energy computerized tomography (CT) reconstruction process (statistical image reconstruction method built on a basis vector model (JSIR-BVM)) implemented on a 16-slice commercial CT scanner to measure high spatial resolution stopping-power ratio (SPR) maps with uncertainties of less than 1%.

Methods: JSIR-BVM was used to reconstruct images of effective electron density and mean excitation energy from dual-energy CT (DECT) sinograms for 10 high-purity samples of known density and atomic composition inserted into head and body phantoms. The measured DECT data consisted of 90 and 140 kVp axial sinograms serially acquired on a Philips Brilliance Big Bore CT scanner without beam-hardening corrections.

View Article and Find Full Text PDF

Photon counting CT (PCCT) is an x-ray imaging technique that has undergone great development in the past decade. PCCT has the potential to improve dose efficiency and low-dose performance. In this paper, we propose a statistics-based iterative algorithm to perform a direct reconstruction of material-decomposed images.

View Article and Find Full Text PDF

Purpose: To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation.

Methods: The JSIR-BVM method builds on the relationship between the energy-dependent photon attenuation coefficients and the proton stopping power via a pair of BVM component weights. The two BVM component images are simultaneously reconstructed from the acquired DECT sinograms and then used to predict the electron density and mean excitation energy (I-value), which are required by the Bethe equation for SPR computation.

View Article and Find Full Text PDF

Computed tomography (CT) examinations are commonly used to predict lung nodule malignancy in patients, which are shown to improve noninvasive early diagnosis of lung cancer. It remains challenging for computational approaches to achieve performance comparable to experienced radiologists. Here we present NoduleX, a systematic approach to predict lung nodule malignancy from CT data, based on deep learning convolutional neural networks (CNN).

View Article and Find Full Text PDF

Purpose: The purpose of this study was to assess the performance of a novel dual-energy CT (DECT) approach for proton stopping power ratio (SPR) mapping that integrates image reconstruction and material characterization using a joint statistical image reconstruction (JSIR) method based on a linear basis vector model (BVM). A systematic comparison between the JSIR-BVM method and previously described DECT image- and sinogram-domain decomposition approaches is also carried out on synthetic data.

Methods: The JSIR-BVM method was implemented to estimate the electron densities and mean excitation energies (I-values) required by the Bethe equation for SPR mapping.

View Article and Find Full Text PDF

Model-based image reconstruction (MBIR) techniques have the potential to generate high quality images from noisy measurements and a small number of projections which can reduce the x-ray dose in patients. These MBIR techniques rely on projection and backprojection to refine an image estimate. One of the widely used projectors for these modern MBIR based technique is called branchless distance driven (DD) projection and backprojection.

View Article and Find Full Text PDF

Purpose: To evaluate and compare the theoretically achievable accuracy of two families of two-parameter photon cross-section models: basis vector model (BVM) and modified parametric fit model (mPFM).

Method: The modified PFM assumes that photoelectric absorption and scattering cross-sections can be accurately represented by power functions in effective atomic number and/or energy plus the Klein-Nishina cross-section, along with empirical corrections that enforce exact prediction of elemental cross-sections. Two mPFM variants were investigated: the widely used Torikoshi model (tPFM) and a more complex "VCU" variant (vPFM).

View Article and Find Full Text PDF

Objective: The aim of this study was to compare the performance of 2- (2D) and 3-dimensional (3D) quantitative computed tomography (CT) methods for classifying lung nodules as lung cancer, metastases, or benign.

Methods: Using semiautomated software and computerized analysis, we analyzed more than 50 quantitative CT features of 96 solid nodules in 94 patients, in 2D from a single slice and in 3D from the entire nodule volume. Multivariable logistic regression was used to classify nodule types.

View Article and Find Full Text PDF

We propose a new algorithm, called line integral alternating minimization (LIAM), for dual-energy X-ray CT image reconstruction. Instead of obtaining component images by minimizing the discrepancy between the data and the mean estimates, LIAM allows for a tunable discrepancy between the basis material projections and the basis sinograms. A parameter is introduced that controls the size of this discrepancy, and with this parameter the new algorithm can continuously go from a two-step approach to the joint estimation approach.

View Article and Find Full Text PDF

Purpose: To provide a noninvasive technique to measure the intensity profile of the fan beam in a computed tomography (CT) scanner that is cost effective and easily implemented without the need to access proprietary scanner information or service modes.

Methods: The fabrication of an inexpensive aperture is described, which is used to expose radiochromic film in a rotating CT gantry. A series of exposures is made, each of which is digitized on a personal computer document scanner, and the resulting data set is analyzed to produce a self-consistent calibration of relative radiation exposure.

View Article and Find Full Text PDF

Purpose: Several areas of computed tomography (CT) research require knowledge about the intensity profile of the x-ray fan beam that is introduced by a bow tie filter. This information is considered proprietary by CT manufacturers, so noninvasive measurement methods are required. One method using real-time dosimeters has been proposed in the literature.

View Article and Find Full Text PDF

We investigate new sampling strategies for projection tomography, enabling one to employ fewer measurements than expected from classical sampling theory without significant loss of information. Inspired by compressed sensing, our approach is based on the understanding that many real objects are compressible in some known representation, implying that the number of degrees of freedom defining an object is often much smaller than the number of pixels/voxels. We propose a new approach based on quasi-random detector subsampling, whereas previous approaches only addressed subsampling with respect to source location (view angle).

View Article and Find Full Text PDF

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasive in vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries.

Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV.

View Article and Find Full Text PDF

Glioblastoma Mulitforme is highly infiltrative, making precise delineation of tumor margin difficult. Multimodality or multi-parametric MR imaging sequences promise an advantage over anatomic sequences such as post contrast enhancement as methods for determining the spatial extent of tumor involvement. In considering multi-parametric imaging sequences however, manual image segmentation and classification is time-consuming and prone to error.

View Article and Find Full Text PDF

Normative values of pediatric skull circumference, cranial index, and braincase volume would inform multiple disciplines including neurosurgery, plastic surgery and anthropology. Semi-automated methods exist for obtaining these data but are time consuming and require expertise. We report on a new method for automated extraction of in vivo measures of pediatric crania based on x-ray computed tomography scans (CT).

View Article and Find Full Text PDF

Skull thickness and density measures of normal pediatric crania would inform multiple disciplines including neurosurgery, optical and magnetoelectrophysiological imaging, and biomechanical modeling of head trauma. We report on a new method for automated extraction of in vivo skull thickness and density measures of pediatric crania based on x-ray computed tomography scans (CT). Data were obtained from a clinical image repository for pediatric populations in whom no pathology was noted.

View Article and Find Full Text PDF

Brain electrical activity exhibits scale-free dynamics that follow power law scaling. Previous works have shown that broadband spectral power exhibits state-dependent scaling with a log frequency exponent that systematically varies with neural state. However, the frequency ranges which best characterize biological state are not consistent across brain location or subject.

View Article and Find Full Text PDF

Purpose: To present a framework for characterizing the data needed to implement a polyenergetic model-based statistical reconstruction algorithm, Alternating Minimization (AM), on a commercial fan-beam CT scanner and a novel method for assessing the accuracy of the commissioned data model.

Methods: The X-ray spectra for three tube potentials on the Philips Brilliance CT scanner were estimated by fitting a semi-empirical X-ray spectrum model to transmission measurements. Spectral variations due to the bowtie filter were computationally modeled.

View Article and Find Full Text PDF

Like many complex dynamic systems, the brain exhibits scale-free dynamics that follow power-law scaling. Broadband power spectral density (PSD) of brain electrical activity exhibits state-dependent power-law scaling with a log frequency exponent that varies across frequency ranges. Widely divergent naturally occurring neural states, awake and slow wave sleep (SWS), were used to evaluate the nature of changes in scale-free indices of brain electrical activity.

View Article and Find Full Text PDF

Purpose: In comparison with conventional filtered backprojection (FBP) algorithms for x-ray computed tomography (CT) image reconstruction, statistical algorithms directly incorporate the random nature of the data and do not assume CT data are linear, noiseless functions of the attenuation line integral. Thus, it has been hypothesized that statistical image reconstruction may support a more favorable tradeoff than FBP between image noise and spatial resolution in dose-limited applications. The purpose of this study is to evaluate the noise-resolution tradeoff for the alternating minimization (AM) algorithm regularized using a nonquadratic penalty function.

View Article and Find Full Text PDF

Simultaneous EEG-fMRI studies require an understanding of the noise characteristics of the acquisition environment so that appropriate pre-processing steps may be taken to remove known artifacts from the data stream. Using a phantom approach, we have developed a general methodology for characterizing non-physiologic noise in EEG signal and demonstrate the use of this methodology for a specific MR scanner and EEG data acquisition system configuration. Our results show the δ frequency band is significantly impacted by baseline drift or baseline correction algorithms while the β and γ bands are impacted by residual gradient artifact and gradient corrections.

View Article and Find Full Text PDF

Two iterative methods are developed for forming a maximum-likelihood estimate of the attenuation density in a patient or object for transmission tomography when projection data are incomplete. The methods converge monotonically to the same limit points. Results of testing the methods with both simulated and real data are given.

View Article and Find Full Text PDF

We address the problem of image formation in transmission tomography when metal objects of known composition and shape, but unknown pose, are present in the scan subject. Using an alternating minimization (AM) algorithm, derived from a model in which the detected data are viewed as Poisson-distributed photon counts, we seek to eliminate the streaking artifacts commonly seen in filtered back projection images containing high-contrast objects. We show that this algorithm, which minimizes the I-divergence (or equivalently, maximizes the log-likelihood) between the measured data and model-based estimates of the means of the data, converges much faster when knowledge of the high-density materials (such as brachytherapy applicators or prosthetic implants) is exploited.

View Article and Find Full Text PDF