The development of algorithms for remote sensing of water quality (RSWQ) requires a large amount of in situ data to account for the bio-geo-optical diversity of inland and coastal waters. The GLObal Reflectance community dataset for Imaging and optical sensing of Aquatic environments (GLORIA) includes 7,572 curated hyperspectral remote sensing reflectance measurements at 1 nm intervals within the 350 to 900 nm wavelength range. In addition, at least one co-located water quality measurement of chlorophyll a, total suspended solids, absorption by dissolved substances, and Secchi depth, is provided.
View Article and Find Full Text PDFTau-mediated neurodegeneration is a hallmark of Alzheimer's disease. Primary tauopathies are characterized by pathological tau accumulation and neuronal and synaptic loss. Apolipoprotein E (ApoE)-mediated neuroinflammation is involved in the progression of tau-mediated neurodegeneration, and emerging evidence suggests that the gut microbiota regulates neuroinflammation in an APOE genotype-dependent manner.
View Article and Find Full Text PDFBackground: Left ventricular (LV) dysfunction is known to occur after right ventricular (RV) pacing; the effect on RV function is less well studied. The aim of this study was to assess the impact of RV mid-septal pacing upon RV function using the novel parameters of speckle-tracking derived RV global longitudinal strain (RV GLS) and RV free wall strain (RV FWS), as well as the conventional parameters RV fractional area change (FAC), tricuspid annular plane systolic excursion (TAPSE), and tricuspid annular systolic velocity (RV S').
Methods: Thirty-two (32) consecutive patients with normal baseline LV and RV function requiring permanent pacemaker insertion (for high-grade AV block or sinus node dysfunction) were prospectively recruited.
Background: Health workers in low- and middle-income countries are increasingly demanded to collect more and more data to report them to higher levels of the health information system (HIS), in detriment of useful data for clinical and public health decision-making, potentially compromising the quality of their health care provison. In order to support health workers' decision-making, we engaged with partners in Côte d'Ivoire, Mozambique and Nigeria in a research project to conceive, design, produce, implement and test paper-based health information tools: the PHISICC tools. Our aim was to understand the use of PHISICC tools by health workers and to improve them based on their feedback.
View Article and Find Full Text PDFBackground: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known.
Methods: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system.
Introduction: The extravascular implantable cardioverter-defibrillato (EV ICD) system with substernal lead placement is a novel nontransvenous alternative to current commercially available ICD systems. The EV ICD provides defibrillation and pacing therapies without the potential long-term complications of endovascular lead placement but requires a new procedure for implantation with a safety profile under evaluation.
Methods: This paper summarizes the development of the EV ICD, including the preclinical and clinical evaluations that have contributed to the system and procedural refinements to date.
Background: Health information systems are crucial to provide data for decision-making and demand for data is constantly growing. However, the link between data and decisions is not always rational or linear and the management of data ends up overloading frontline health workers, which may compromise quality of healthcare delivery. Despite limited evidence, there is an increasing push for the digitalization of health information systems, which poses enormous challenges, particularly in remote, rural settings in low- and middle-income countries.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
September 2021
Background: Transvenous implantable cardioverter defibrillators (TV ICD) provide life-saving therapy for millions of patients worldwide. However, they are susceptible to several potential short- and long- term complications including cardiac perforation and pneumothorax, lead dislodgement, venous obstruction, and infection. The extravascular ICD system's novel design and substernal implant approach avoids the risks associated with TV ICDs while still providing pacing features and similar generator size to TV ICDs.
View Article and Find Full Text PDFBackground: Cardiac resynchronization therapy (CRT) involves stimulation of both right ventricle (RV) and left ventricle (LV). LV pacing from the sites of delayed electrical activation improves CRT response. The RV-LV conduction is typically measured in intrinsic rhythm.
View Article and Find Full Text PDFBackground: There is uncertainty regarding whether outcomes after Cardiac Implantable Electronic Devices (CIED) differ between women and men. There are no prospectively collected data regarding Australian CIED outcomes. This study aimed to determine whether the characteristics and outcomes of Australian patients undergoing CIED implantation differ by sex.
View Article and Find Full Text PDFThe concept that gut microbiome-expressed functions regulate ponderal growth has important implications for infant and child health, as well as animal health. Using an intergenerational pig model of diet restriction (DR) that produces reduced weight gain, we developed a feature-selection algorithm to identify representative characteristics distinguishing DR fecal microbiomes from those of full-fed (FF) pigs as both groups consumed a common sequence of diets during their growth cycle. Gnotobiotic mice were then colonized with DR and FF microbiomes and subjected to controlled feeding with a pig diet.
View Article and Find Full Text PDFBackground: Cardiac fibrosis in mitral valve prolapse (MVP) is implicated in the development of sudden cardiac death (SCD); however, the pattern remains poorly characterized.
Objective: The purpose of this study was to systematically quantify left and right ventricular fibrosis in individuals with isolated MVP and SCD (iMVP-SCD), whereby other potential causes of death are excluded, compared to a control cohort.
Methods: Individuals with iMVP-SCD were identified from the Victorian Institute of Forensic Medicine, Australia, and matched for age, sex, and body mass index to control cases with noncardiac death.
Objectives: The aim of this study was to evaluate the safety and performance of an extravascular (EV) implantable cardioverter-defibrillator (ICD).
Background: Limitations of existing transvenous and subcutaneous ICD systems include lead reliability and morbidity issues associated with ICD lead implantation in the vasculature or lack of pacing therapies (e.g.
Circ Cardiovasc Qual Outcomes
October 2020
Background: Sudden cardiac death (SCD) in the young is devastating. Contemporary incidence remains unclear with few recent nationwide studies and limited data addressing risk factors for causes. We aimed to determine incidence, trends, causes, and risk factors for SCD in the young.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
September 2021
Purpose: Multipoint pacing (MPP) improves left ventricular (LV) electrical synchrony in cardiac resynchronization therapy (CRT). SyncAV automatically adjusts atrioventricular delay (AVD) according to intrinsic AV intervals and may further improve synchrony. Their combination has not been assessed.
View Article and Find Full Text PDFBackground The association between mitral valve prolapse (MVP) and sudden death remains controversial. We aimed to describe histopathological changes in individuals with autopsy-determined isolated MVP (iMVP) and sudden death and document cardiac arrest rhythm. Methods and Results The Australian National Coronial Information System database was used to identify cases of iMVP between 2000 and 2018.
View Article and Find Full Text PDFBackground: The AdaptivCRT (aCRT) algorithm continuously adjusts cardiac resynchronization therapy (CRT) according to intrinsic atrioventricular conduction, providing synchronized left ventricular pacing in patients with normal PR interval and adaptive BiV pacing in patients with prolonged PR interval. Previous analyses demonstrated an association between aCRT and clinical benefit. We evaluated the incidence of patient mortality and atrial fibrillation (AF) with aCRT compared with standard CRT in a real-world population.
View Article and Find Full Text PDFGiven the increasing use of gnotobiotic mouse models for deciphering the effects of human microbial communities on host biology, there is a need to develop new methods for characterizing these animals while maintaining their isolation from environmental microbes. We describe a method for performing open-circuit indirect calorimetry on gnotobiotic mice colonized with gut microbial consortia obtained from different human donors. In this illustrative case, cultured collections of gut bacterial strains were obtained from obese and lean co-twins.
View Article and Find Full Text PDFBackground: Postoperative heart block is common among patients undergoing surgery for infective endocarditis (IE). Limited data exists allowing cardiologists to predict who will require permanent pacemaker (PPM) implantation postoperatively. We aimed to determine the rate of postoperative PPM insertion, predictors for postoperative PPM, and describe PPM utilization and rates of device-related infection during follow-up.
View Article and Find Full Text PDFIn the version of this article initially published, grant PF-17-201-01-TBG from the American Cancer Society to author Erica C. Pehrsson was not included in the Acknowledgements. The error has been corrected in the HTML and PDF versions of the article.
View Article and Find Full Text PDF