Publications by authors named "David Mego"

The MitraClip system can be used to control regurgitant blood flow in patients with mitral regurgitation who cannot tolerate open surgery to replace the mitral valve. Technical limitations make the right femoral vein the standard access point for placing the MitraClip. However, this route is not always suitable.

View Article and Find Full Text PDF

Purpose: Zilver PTX nitinol self-expanding drug-eluting stent with paclitaxel coating is effective for treatment of superficial femoral artery (SFA) disease. However, as with any stent, it induces a measure of vascular inflammatory response. The current clinical trial (NCT02734836) aimed to assess vascular patency, remodeling, and inflammatory markers with intravascular optical coherence tomography (OCT) in patients with SFA disease treated with Zilver PTX stents.

View Article and Find Full Text PDF

Background And Purpose: Transradial percutaneous coronary intervention (TR-PCI) has been increasingly popular over the last decade in the US. Previous studies have shown that same-day (SD) discharge after elective PCI is as safe as overnight (ON) observation. Our study was performed to assess the clinical and financial impact of early discharge in patients undergoing TR-PCI.

View Article and Find Full Text PDF

Background: Long-term patency rates for percutaneous peripheral arterial interventions are suboptimal. Optical coherence tomography (OCT) guided atherectomy may yield superior patency by optimizing plaque removal while preserving the tunica media and adventitia.

Methods: The VISION study is a multicenter prospective study of patients with peripheral arterial disease undergoing OCT guided atherectomy with the Pantheris™ device.

View Article and Find Full Text PDF

Background/purpose: Bare metal stents (BMS) have similar rates of death and myocardial infarction (MI) compared to drug-eluting stents (DES). DES lower repeat revascularization rates compared to BMS, but may have higher rates of late stent thrombosis (ST) potentially due to impaired endothelialization requiring longer dual anti-platelet therapy (DAPT). OMEGA evaluated a novel BMS designed to have improved deliverability and radiopacity, in comparison to currently available platforms.

View Article and Find Full Text PDF

Congestive heart failure (CHF) secondary to ischemic cardiomyopathy is associated with significant morbidity and mortality despite currently available medical therapy. The Parachute(TM) device is a novel left ventricular partitioning device that is delivered percutaneously in the left ventricle (LV) in patients with anteroapical regional wall motion abnormalities, dilated LV and systolic dysfunction after anterior myocardial infarction with favorable clinical and LV hemodynamic improvements post-implantation. Here, we do review the current literature and present a case of the Parachute device implantation.

View Article and Find Full Text PDF

Purpose: The primary aim of this study was to prospectively evaluate the safety and efficacy of Excimer laser atherectomy as a primary treatment strategy in consecutively eligible patients presenting for percutaneous coronary intervention (PCI) of degenerated saphenous vein graft (SVG) lesions using a multicenter registry. Prior single-center experience suggested that laser atherectomy may decrease acute procedural complications during treatment of degenerated SVGs, including lesions not amenable to distal protection devices (DPDs).

Methods And Materials: The COronary graft Results following Atherectomy with Laser investigators enrolled 98 patients at 18 centers between June 23, 2003, and October 4, 2004, with greater than 50% stenosis of an SVG who presented for PCI due to angina pectoris or objective evidence of myocardial ischemia in a concordant myocardial distribution.

View Article and Find Full Text PDF

Background: Arterial puncture closure devices have improved time to hemostasis and ambulation after percutaneous coronary intervention (PCI) relative to traditional manual compression, though complication rates for both methods leave room for improvement. In a pilot registry, the authors evaluated a topical hemostatic dressing containing poly-N-acetyl glucosamine (p-GlcNAc) post PCI in fully anticoagulated patients.

Methods And Results: In 100 patients undergoing PCI via the common femoral artery in the short-stay unit, the p-GlcNAc hemostatic dressing was applied with 15 minutes of manual compression at arterial access sites after arterial sheath removal.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionrdeta1l8aaq48tjlmc1gv38774msv72s): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once