Publications by authors named "David M Page"

Background: Electrical stimulation of residual afferent nerve fibers can evoke sensations from a missing limb after amputation, and bionic arms endowed with artificial sensory feedback have been shown to confer functional and psychological benefits. Here we explore the extent to which artificial sensations can be discriminated based on location, quality, and intensity.

Methods: We implanted Utah Slanted Electrode Arrays (USEAs) in the arm nerves of three transradial amputees and delivered electrical stimulation via different electrodes and frequencies to produce sensations on the missing hand with various locations, qualities, and intensities.

View Article and Find Full Text PDF

Objective: We explore the long-term performance and stability of seven percutaneous Utah Slanted Electrode Arrays (USEAs) and intramuscular recording leads (iEMGs) implanted chronically in the residual arm nerves and muscles of three human participants as a means to permanently restore sensorimotor function after transradial amputations.

Approach: We quantify the number of functional recording and functional stimulating electrodes over time. We also calculate the signal-to-noise ratio (SNR) of USEA and iEMG recordings and quantify the stimulation current necessary to evoke detectable sensory percepts.

View Article and Find Full Text PDF

Although recent advances in neuroprostheses offer opportunities for improved and intuitive control of advanced motorized and sensorized robotic arms, practical complications associated with such hardware can impede the research necessary for clinical translation. These hurdles potentially can be reduced with virtual reality environments (VREs) with embedded physics engines using virtual models of physical robotic hands. These software suites offer several advantages over physical prototypes, including high repeatability, reduced human error, elimination of many secondary sensory cues, and others.

View Article and Find Full Text PDF

We quantified prosthesis embodiment and phantom pain reduction associated with motor control and sensory feedback from a prosthetic hand in one human with a long-term transradial amputation. Microelectrode arrays were implanted in the residual median and ulnar arm nerves and intramuscular electromyography recording leads were implanted in residual limb muscles to enable sensory feedback and motor control. Objective measures (proprioceptive drift) and subjective measures (survey answers) were used to assess prosthesis embodiment.

View Article and Find Full Text PDF

Objectives: Kilohertz high-frequency alternating current (KHFAC) electrical nerve stimulation produces a reversible nerve block in peripheral nerves in human patients with chronic pain pathologies. Although this stimulation methodology has been verified with nonselective extrafascicular electrodes, the effectiveness of producing a selective nerve block with more-selective intrafascicular electrodes has not been well documented. The objective of this study was to examine whether intrafascicular electrodes can block painful stimuli while preserving conduction of other neural activity within the implanted nerve.

View Article and Find Full Text PDF

Background: Despite advances in sophisticated robotic hands, intuitive control of and sensory feedback from these prostheses has been limited to only 3-degrees-of-freedom (DOF) with 2 sensory percepts in closed-loop control. A Utah Slanted Electrode Array (USEA) has been used in the past to provide up to 81 sensory percepts for human amputees. Here, we report on the advanced capabilities of multiple USEAs implanted in the residual peripheral arm nerves of human amputees for restoring control of 5 DOF and sensation of up to 131 proprioceptive and cutaneous hand sensory percepts.

View Article and Find Full Text PDF

Signals recorded from the peripheral nervous system (PNS) with high channel count penetrating microelectrode arrays, such as the Utah Slanted Electrode Array (USEA), often have electromyographic (EMG) signals contaminating the neural signal. This common-mode signal source may prevent single neural units from successfully being detected, thus hindering motor decode algorithms. Reducing this EMG contamination may lead to more accurate motor decode performance.

View Article and Find Full Text PDF

Peripheral nerve interfaces that can record from and stimulate large numbers of different nerve fibers selectively and independently may help restore intuitive and effective motor and sensory function after hand amputation. To this end, and extending previous work in two subjects, two 100-electrode Utah Slanted Electrode Arrays (USEAs) were implanted for four weeks in the residual ulnar and median nerves of a 50-year-old male whose left, dominant hand had been amputated 21 years previously. Subsequent experiments involved 1) recording from USEAs for real-time control of a virtual prosthetic hand; 2) stimulation to evoke somatosensory percepts; and 3) closed-loop sensorimotor control.

View Article and Find Full Text PDF