Publications by authors named "David Loy"

Objective: In the following years after the United States Preventive Service Task Force (USPSTF) recommendation against prostate cancer screening with PSA in 2012, several authors worldwide described an increase in higher grades and aggressive prostate tumors. In this scenario, we aim to evaluate the potential impacts of USPSTF recommendations on the functional and oncological outcomes in patients undergoing robotic-assisted radical prostatectomy (RARP) in a referral center.

Material And Methods: We included 11396 patients who underwent RARP between 2008 and 2021.

View Article and Find Full Text PDF

Background: The Neuroform Atlas Stent System is an established treatment modality for unruptured anterior and posterior circulation intracranial aneurysms. Location-specific results are needed to guide treatment decision-making. However, it is unclear whether there are differences in safety and efficacy outcomes between carotid and more distal anterior circulation aneurysms.

View Article and Find Full Text PDF

The new SP robot incorporates a single trocar that houses a flexible camera and three bi-articulated arms, which minimize the number of incisions needed to assess the surgical site, allowing for a less invasive procedure. To compare the postoperative pain scale and outcomes in patients with similar demographic characteristics undergoing robotic-assisted radical prostatectomy (RARP) with SP and Xi robots, One-hundred consecutive patients undergoing RARP with the SP robot were matched, using a propensity score (PS), with 100 patients from a cohort of 1757 who were operated on with the da Vinci Xi from June 2019 to January 2021. We described and compared the perioperative pain scores and outcomes of both groups.

View Article and Find Full Text PDF

Introduction: Urolift® is a surgical modality to treat lower urinary tract symptoms (LUTS) in patients with enlarged prostates (1). However, the inflammatory process caused by the device usually displaces the prostate's anatomical landmarks and challenges surgeons performing robotic-assisted radical prostatectomy (RARP). In this video, we will illustrate several technical challenges in patients with Urolift ® who underwent RARP.

View Article and Find Full Text PDF

Background: Heterogeneous effect of endovascular aneurysm therapy has been observed across different anatomic locations. There is a paucity of data for stent-assisted coiling of middle cerebral artery (MCA) aneurysms.

Objective: To present the results of the MCA aneurysm group from the Neuroform Atlas (Stryker Neurovascular) investigational device exemption (IDE) trial.

View Article and Find Full Text PDF

Background: Stent-assisted coiling of wide-necked intracranial aneurysms (IAs) using the Neuroform Atlas Stent System (Atlas) has shown promising results.

Objective: To present the primary efficacy and safety results of the ATLAS Investigational Device Exemption (IDE) trial in a cohort of patients with posterior circulation IAs.

Methods: The ATLAS trial is a prospective, multicenter, single-arm, open-label study of unruptured, wide-necked, IAs treated with the Atlas stent and adjunctive coiling.

View Article and Find Full Text PDF

Background And Purpose: Stent-assisted coil embolization using the new generation Neuroform Atlas Stent System has shown promising safety and efficacy. The primary study results of the anterior circulation aneurysm cohort of the treatment of wide-neck, saccular, intracranial, aneurysms with the Neuroform Atlas Stent System (ATLAS trial [Safety and Effectiveness of the Treatment of Wide Neck, Saccular Intracranial Aneurysms With the Neuroform Atlas Stent System]) are presented.

Methods: ATLAS IDE trial (Investigational Device Exemption) is a prospective, multicenter, single-arm, open-label study of wide-neck (neck ≥4 mm or dome-to-neck ratio <2) intracranial aneurysms in the anterior circulation treated with the Neuroform Atlas Stent and approved coils.

View Article and Find Full Text PDF

Background And Objective: Stent-assisted coil embolization is a well-established treatment of intracranial wide-necked aneurysms. The Neuroform Atlas Stent System is a new generation microstent designed to enhance coil support, conformability, deliverability, and improve deployment accuracy. We present the 1-year efficacy and angiographic results of the Humanitarian Device Exemption (HDE) cohort from the Atlas Investigational Device Exemption (IDE) clinical trial.

View Article and Find Full Text PDF

Background: Mechanical thrombectomy (MT) is the current standard of care for acute ischemic stroke (AIS) patients with emergent large-vessel occlusions (ELVO). Successful reperfusion of ELVO is traditionally defined by modified Thrombolysis in Cerebral Infarction (mTICI) grades of 2b or 3.

Objective: To evaluate the comparative safety and efficacy of mTICI 2b and mTICI 3 reperfusion in AIS patients treated with MT.

View Article and Find Full Text PDF

Objective: In this multicenter study, we sought to evaluate comparative safety and efficacy of combined IV thrombolysis (IVT) and mechanical thrombectomy (MT) vs direct MT in emergent large vessel occlusion (ELVO) patients.

Methods: Consecutive ELVO patients treated with MT at 6 high-volume endovascular centers were evaluated. Standard safety and efficacy outcomes (successful reperfusion [modified Thrombolysis in Cerebral Infarction IIb/III], functional independence [FI] [modified Rankin Scale (mRS) score of 0-2 at 3 months], favorable functional outcome [mRS of 0-1 at 3 months], functional improvement [mRS shift by 1-point decrease in mRS score]) were compared between patients who underwent combined IVT and MT vs MT alone.

View Article and Find Full Text PDF

Background: Cerebral venous thrombosis is a rare cause of stroke that poses diagnostic, therapeutic, and prognostic challenges. Mainstay treatment is systemic anticoagulation, but endovascular treatment is increasingly advocated. Our objectives were to describe the epidemiology, treatment, and prognosis of 152 patients with cerebral venous thrombosis.

View Article and Find Full Text PDF

Background: While mechanical thrombectomy (MT) has become the standard of care for patients with acute ischemic stroke (AIS) with emergent large-vessel occlusions (ELVO), recently published guidelines appropriately award top-tier evidence to the same selective criteria that were employed in completed clinical trials. We sought to evaluate the safety and effectiveness of MT in patients with AIS with ELVO who do not meet top-tier evidence criteria (TTEC).

Methods: We conducted an observational study on consecutive patients with AIS with ELVO who underwent MT at six high-volume endovascular centers.

View Article and Find Full Text PDF

Background And Purpose: Intra-arterial therapy (IAT) is most effective when performed rapidly after ischemic stroke onset. However, there are limited performance benchmarks in IAT and there is a scarcity of information on how to structure an effective IAT protocol and its impact on time to treatment. The objective of our study was to detail a standardized IAT protocol, and to assess its influence on time to treatment in ischemic stroke.

View Article and Find Full Text PDF

Background/objective: Traditional platinum coils used for cerebral aneurysm embolization have a uniform degree of softness throughout an individual coil's length. Recently, SMART Coils (Penumbra Inc., Alameda, California, USA) have been developed, which transition in softness along the length of their coils.

View Article and Find Full Text PDF

Objective: The safety and efficacy of intra-arterial treatment (IAT) in patients with acute ischemic stroke (AIS) due to cervical artery dissection (CeAD) has not been formally studied. The purpose of this study was twofold: first, describe a large series with CeAD treated with IAT; second, analyze outcomes with CeAD receiving IAT versus (a) CeAD not treated with IAT, (b) CeAD receiving intravenous thrombolysis (IVT) alone, and (c) non-CeAD mechanism of AIS receiving IAT.

Design: Demographics, clinical characteristics, treatment, and outcomes were summarized for all CeAD patients treated with IAT from January 2010 to May 2015.

View Article and Find Full Text PDF

Background: Clinical trials confirmed the safety and efficacy of intra-arterial therapy (IAT) in the management of ischemic stroke. At a community hospital, we compared outcomes in patients aged ≥80 and patients in the age range 55-79 years receiving IAT following ischemic stroke.

Methods: Data were retrospectively abstracted for ischemic stroke patients ≥55 years treated with IAT at an urban comprehensive stroke center between 2010 and 2013.

View Article and Find Full Text PDF

Objective: Flexible large lumen aspiration catheters and stent retrievers have recently become available in the USA for the revascularization of large vessel occlusions presenting within the context of acute ischemic stroke (AIS). We describe a multicenter experience using a combined aspiration and stent retrieval technique for thrombectomy.

Design: A retrospective analysis to identify patients receiving combined manual aspiration and stent retrieval for treatment of AIS between August 2012 and April 2013 at six high volume stroke centers was conducted.

View Article and Find Full Text PDF

Background: The treatment of acute ischemic stroke is traditionally centered on time criteria, although recent evidence suggests that physiologic neuroimaging may be useful. In a multicenter study we evaluated the use of CT perfusion, regardless of time from symptom onset, in patients selected for intra-arterial treatment of ischemic stroke.

Methods: Three medical centers retrospectively assessed stroke patients with a National Institute of Health Stroke Scale of ≥ 8, regardless of time from symptom onset.

View Article and Find Full Text PDF

Accurate diagnosis of spinal cord injury (SCI) severity must be achieved before highly aggressive experimental therapies can be tested responsibly in the early phases after trauma. These studies demonstrate for the first time that axial diffusivity (lambda||), derived from diffusion tensor imaging (DTI) within 3 h after SCI, accurately predicts long-term locomotor behavioral recovery in mice. Female C57BL/6 mice underwent sham laminectomy or graded contusive spinal cord injuries at the T9 vertebral level (5 groups, n = 8 for each group).

View Article and Find Full Text PDF

This report demonstrates that time-of-flight (TOF) MR angiography is a useful adjunct for planning stereotactic radiosurgery (SRS) of large arteriovenous malformations (AVMs) after staged embolization with Onyx. Onyx (ethylene vinyl copolymer), a recently approved liquid embolic agent, has been increasingly used to exclude portions of large AVMs from the parent circulation prior to SRS. Limiting SRS to regions of persistent arteriovenous shunting and excluding regions eliminated by embolization may reduce unnecessary radiation doses to eloquent brain structures.

View Article and Find Full Text PDF

We examined in vivo measurements of directional diffusivity derived from diffusion tensor imaging (DTI) to study the evolution of ventrolateral white matter (VWM) changes following contusive spinal cord injury (SCI) in C57BL/6 mice at 1, 3, 7, and 14 days postinjury. Relative anisotropy maps provided excellent gray matter (GM)/white matter (WM) contrast for characterization of evolving WM injury at all time points. Longitudinal DTI measurements clearly demonstrated rostral-caudal injury asymmetry.

View Article and Find Full Text PDF

Experimental strategies that focus on ventral white matter (VWM) preservation during the hyperacute phase hold great potential for our improved understanding of functional recovery following traumatic spinal cord injury (SCI). Critical comparisons of human SCI to rapidly accumulating data derived from rodent models are limited by a basic lack of in vivo measures of subclinical pathophysiologic changes and white matter damage in the spinal cord. Spinal cord edema and intraparenchymal hemorrhage demonstrated with routine MR sequences have limited value for predicting functional outcomes in SCI animal models and in human patients.

View Article and Find Full Text PDF