Background: By 2060, the incidence of ADRD is predicted to increased 6-fold in the US Hispanic population (Matthews, Xu et al. 2019). However, cognitive testing of US Hispanics is complicated by limited Spanish-language test materials and a dearth of examiners fluent in Spanish.
View Article and Find Full Text PDFBackground: Paper-and-pencil neuropsychological tests have traditionally been considered the "gold standard" for clinical testing in AD/ADRD, but they have significant limitations: They are time-consuming, costly to administer, vulnerable to examiner bias and error, and unavailable to some patients due to location, transportation challenges, and cost. Manual tests also fail to comprehensively analyze many aspects of test performance. Computerized neuropsychological test batteries have been developed to address these shortcomings.
View Article and Find Full Text PDFPurpose: To characterize the hepatic and abdominal angiographic anatomy of woodchucks and vascular changes associated with hepatocellular carcinoma (HCC).
Materials And Methods: Twenty-nine woodchucks (23 with viral-associated HCC, 6 without) underwent multiphasic computed tomography (CT). Fourteen woodchucks (8 with HCC) also underwent diagnostic angiography.
Purpose: To assess the feasibility of inducing vascular occlusion by application of radiofrequency (RF) energy via conductive endovascular wires or baskets.
Materials And Methods: A retrievable nitinol basket and stainless steel guidewire with a platinum tip were evaluated as conductors for endovascular application of RF energy. Tissue-mimicking thermochromic gel phantoms that change color with heating were cast with 2-, 5-, and 7-mm-diameter lumens and filled with 37 C saline.
Purpose: Topotecan is a camptothecin analogue with potential advantages over irinotecan for transarterial chemoembolization (TACE) of hepatic colorectal metastases including greater anti-neoplastic activity without enzymatic activation. The purpose of this study was to assess safety and tolerability of topotecan-loaded radiopaque microspheres (ROMTOP) administered by TACE in a rabbit model and to compare the in vitro elution of topotecan from microspheres to irinotecan.
Materials And Methods: Topotecan was loaded into radiopaque microspheres (70-150 µm, DC Bead LUMI™, Biocompatibles UK Ltd-Boston Scientific Corporation) to the maximum capacity of 80 mg/mL of microspheres.
Purpose: To assess the feasibility of transarterial chemoembolization with drug-eluting embolic (DEE) microspheres in a woodchuck model of hepatocellular carcinoma (HCC).
Materials And Methods: Nine woodchucks were studied: 4 normal animals and 5 animals infected with woodchuck hepatitis virus in which HCC had developed. Three animals with HCC underwent multidetector CT.
Retrievable inferior vena cava (IVC) filters are self-expanding metallic devices implanted in the IVC to prevent migration of thrombi from the deep veins of the legs and pelvis to the lungs. The risk of complications from the filters increases with duration of implantation, but retrieval may be difficult due to intimal hyperplasia around the components of the filter. In this study, the potential for delivery of radiofrequency (RF) energy to the IVC wall via the filter was investigated.
View Article and Find Full Text PDFAfr J Prim Health Care Fam Med
January 2019
Background: Changing global health and development trends have resulted in a need for continued professional development (CPD) within the health and development sectors. In low-resource settings, where the need for training and CPD may be highest, there are significant challenges for disseminating information and skills. There is a need to improve mental health literacy and reduce levels of stigma about maternal mental illness.
View Article and Find Full Text PDFThe Paced Auditory Serial Addition Test (PASAT) is widely used to evaluate processing speed and executive function in patients with multiple sclerosis, traumatic brain injury, and other neurological disorders. In the PASAT, subjects listen to sequences of digits while continuously reporting the sum of the last two digits presented. Four different stimulus onset asynchronies (SOAs) are usually tested, with difficulty increasing as SOAs are reduced.
View Article and Find Full Text PDFPurpose: To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings.
Materials And Methods: Swine (n = 3) underwent hepatic transarterial embolization (n = 6) with the use of 70-150-μm ROBs under fluoroscopic guidance. After stasis, in vivo cone-beam CT was performed at 120, 100, and 80 kVp.
We have developed a straightforward and efficient method of introducing radiopacity into Polyvinyl alcohol (PVA)-2-Acrylamido-2-methylpropane sulfonic acid (AMPS) hydrogel beads (DC Bead™) that are currently used in the clinic to treat liver malignancies. Coupling of 2,3,5-triiodobenzaldehyde to the PVA backbone of pre-formed beads yields a uniformly distributed level of iodine attached throughout the bead structure (~150mg/mL) which is sufficient to be imaged under standard fluoroscopy and computed tomography (CT) imaging modalities used in treatment procedures (DC Bead LUMI™). Despite the chemical modification increasing the density of the beads to ~1.
View Article and Find Full Text PDFVerbal learning tests (VLTs) are widely used to evaluate memory deficits in neuropsychiatric and developmental disorders. However, their validity has been called into question by studies showing significant differences in VLT scores obtained by different examiners. Here we describe the computerized Bay Area Verbal Learning Test (BAVLT), which minimizes inter-examiner differences by incorporating digital list presentation and automated scoring.
View Article and Find Full Text PDFIn verbal fluency (VF) tests, subjects articulate words in a specified category during a short test period (typically 60 s). Verbal fluency tests are widely used to study language development and to evaluate memory retrieval in neuropsychiatric disorders. Performance is usually measured as the total number of correct words retrieved.
View Article and Find Full Text PDFThe 4th edition of the Guidelines for Maternal Care in South Africa published by the National Department of Health in 2015 was evaluated with relevance to the care and prevention of congenital disorders (CDs). Disparate terminology is used for CDs throughout the guidelines, and overall less detail is included on CDs compared with the previous edition. This demonstrates a lack of awareness around the growing health need and contribution of CDs to the disease burden in South Africa (SA).
View Article and Find Full Text PDFTests of design fluency (DF) assess a participant's ability to generate geometric patterns and are thought to measure executive functions involving the non-dominant frontal lobe. Here, we describe the properties of a rapidly administered computerized design-fluency (C-DF) test that measures response times, and is automatically scored. In Experiment 1, we found that the number of unique patterns produced over 90 s by 180 control participants (ages 18 to 82 years) correlated with age, education, and daily computer-use.
View Article and Find Full Text PDFSpatial span tests (SSTs) such as the Corsi Block Test (CBT) and the SST of the Wechsler Memory Scale are widely used to assess deficits in spatial working memory. We conducted three experiments to evaluate the test-retest reliability and clinical sensitivity of a new computerized spatial span test (C-SST) that incorporates psychophysical methods to improve the precision of spatial span measurement. In Experiment 1, we analyzed C-SST test-retest reliability in 49 participants who underwent three test sessions at weekly intervals.
View Article and Find Full Text PDFPurpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70-150-μm radiopaque microspheres in saline (radiopaque microsphere group), 70-150-μm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70-150-μm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group).
View Article and Find Full Text PDFChoice reaction time (CRT), the time required to discriminate and respond appropriately to different stimuli, is a basic measure of attention and processing speed. Here, we describe the reliability and clinical sensitivity of a new CRT test that presents lateralized visual stimuli and adaptively adjusts stimulus onset asynchronies using a staircase procedure. Experiment 1 investigated the test-retest reliability in three test sessions performed at weekly intervals.
View Article and Find Full Text PDFSimple reaction time (SRT), the latency to respond to a stimulus, has been widely used as a basic measure of processing speed. In the current experiments, we examined clinically-relevant properties of a new SRT test that presents visual stimuli to the left or right hemifield at varying stimulus onset asynchronies (SOAs). Experiment 1 examined test-retest reliability in 48 participants who underwent three test sessions at weekly intervals.
View Article and Find Full Text PDFJ Vasc Interv Radiol
January 2016
Purpose: To develop a simple method to produce radiopaque drug-eluting microspheres (drug-eluting beads [DEBs]) that could be incorporated into the current clinical transcatheter arterial chemoembolization workflow and evaluate their performance in vitro and in vivo.
Materials And Methods: An ethiodized oil (Lipiodol; Guerbet, Villepinte, France) and ethanol solution was added to a lyophilized 100-300 µm bead before loading with doxorubicin. These radiopaque drug-eluting beads (DEBs; Biocompatibles UK Ltd, Farnham, United Kingdom) were evaluated in vitro for x-ray attenuation, composition, size, drug loading and elution, and correlation between attenuation and doxorubicin concentration.
In the widely used Corsi Block Test and Wechsler Spatial Span Tests, participants must reproduce sequences of blocks in the order touched by the examiner until two trials are missed at the same sequence length. The examiner records either the maximum number of blocks correctly reported or the total number of correct lists. Here, we describe a computerized spatial span test (C-SST) that uses psychophysical procedures to quantify visuospatial mean span (MnS) with sub-digit precision.
View Article and Find Full Text PDFPurpose: To quantify changes in tumor microvascular (< 1 mm) perfusion relative to commonly used angiographic endpoints.
Materials And Methods: Rabbit Vx2 liver tumors were embolized with 100-300-μm LC Bead particles to endpoints of substasis or complete stasis (controls were not embolized). Microvascular perfusion was evaluated by delivering two different fluorophore-conjugated perfusion markers (ie, lectins) through the catheter before embolization and 5 min after reaching the desired angiographic endpoint.
Purpose: To evaluate the effect of embolic diameter on achievement of hypoxia after embolization in an animal model of liver tumors.
Materials And Methods: Inoculation of VX2 tumors in the left liver lobe was performed successfully in 12 New Zealand white rabbits weighing 3.7 kg ± 0.
The trail making test (TMT) is widely used to assess speed of processing and executive function. However, normative data sets gathered at different sites show significant inconsistencies. Here, we describe a computerized version of the TMT (C-TMT) that increases the precision and replicability of the TMT by permitting a segment-by-segment analysis of performance and separate analyses of dwell-time, move-time, and error time.
View Article and Find Full Text PDF