Background: To date, long-term results of the arthroscopic repair of glenoid rim fractures are missing. The aim of this study was, to evaluate clinical and radiographic results following arthroscopic repair of anteroinferior glenoid fractures using anchors or bioabsorbable compression screws after a mean follow-up period of 10 years.
Methods: Clinical outcome measures included evaluation of recurrent instability, the Constant Score, Subjective Shoulder Value, Rowe Score (RS), Western Ontario Shoulder Instability Score, and Melbourne Instability Shoulder Score.
Preparation requires technical research and development, as well as adaptive, proactive governance.
View Article and Find Full Text PDFThe uncertainty of lidar measured atmospheric temperature or line-of-sight (LOS) wind is inversely proportional to the signal-to-noise ratio (SNR) of the received photocounts. We term the proportionality constant, which depicts the efficacy of the measurement method, the single-photon (or unity SNR) measurement uncertainty for and/or measurement. In this study, we use the single-photon measurement uncertainty as the figure of merit to compare and understand the practical differences between Cabannes scattering (CS), Rayleigh inversion (RI), rotational Raman (RR), and laser induced fluorescence (LIF) lidars for atmospheric temperature and wind measurements, and to optimize the choice and receiver design of a lidar system for a potential application.
View Article and Find Full Text PDFA 60-year-old female was admitted to internal medicine with a painful left knee after a fall and pneumonia. She had undergone a primary cemented left total knee arthroplasty in 2019 and a right cemented total knee arthroplasty in 2021. She had also a history of rheumatoid arthritis treated with steroids and a Janus kinase 1 (JAK1) inhibitor (upadacitinib).
View Article and Find Full Text PDFIncident sharing, auditing, and other concrete mechanisms could help verify the trustworthiness of actors.
View Article and Find Full Text PDFIntroduction: Early results using injectable autologous chondrocyte implantation (ACI) for the treatment of full thickness acetabular cartilage defects have been promising. However, so far there is no information on radiological results after injectable ACI using spheroids. The purpose of this sturdy was to (1) investigate the quality of tissue repair on MRI and (2) investigate the correlation between the MRI results and clinical results at a minimum follow-up of 24 months after third generation ACI in full thickness acetabular cartilage defects.
View Article and Find Full Text PDFUsing an atomic/molecular vapor as an aerosol blocking filter for atmospheric temperature measurements with a Cabannes lidar is revisited. Different problems in previously used barium and iodine filters prevented them from delivering the 78 times signal advantage (8.8 times less uncertainty) over rotational Raman lidar.
View Article and Find Full Text PDFBackground: The subjective hip value (SHV) was developed as a patient-reported outcome measurement (PROM) that is easily and quickly performed and interpreted. The SHV is defined as a patient's subjective hip measurement tool expressed as a percentage of an entirely normal hip joint, which would score 100%. The hypothesis is that results of the subjective hip value correlate with the results of the modified Harris hip score and the International Hip Outcome Tool in patients with hip-related diseases.
View Article and Find Full Text PDFTo evaluate the clinical outcome after arthroscopic matrix-associated injectable autologous chondrocyte implantation (ACI) in patients with large full-thickness acetabular cartilage defects. ACI was performed in young patients with full-thickness acetabular cartilage defects ≥2 cm in a two-step arthroscopic procedure. The patients were followed closely with clinical examinations and pre- and postoperative scores.
View Article and Find Full Text PDFIntroduction: A hypertrophic AIIS has been identified as a cause for extraarticular hip impingement and is classified according to Hetsroni using 3D-CT reconstructions. The role of the conventional AP pelvis X-ray, which is the first standard imaging step for the evaluation of hip pain, has not been investigated yet.
Materials And Methods: AP pelvis X-rays and 3D-CT reconstructions of patients were evaluated regarding their morphology of the AIIS.
Introduction: Acetabular cartilage lesions are frequently seen in young patients with hip pain and have been identified as an important prognostic factor. New therapies have complemented abrasion and microfracture procedures. The aim of the study is to evaluate the early outcome of patients with arthroscopic injectable autologous chondrocyte transplantations (ACT) for full thickness acetabular cartilage defects.
View Article and Find Full Text PDFBackground: The optimal treatment of large anterior glenoid rim fractures is still a matter of debate. The purpose of this study was to evaluate the clinical and radiologic results of an arthroscopic reduction and fixation of acute displaced large solitary or multifragmented anterior glenoid rim fractures using anchors or bioabsorbable compression screws.
Methods: Twenty-three consecutive patients (7 women, 16 men; mean age, 47.
Narrowband Na lidar measurement of mesopause region temperatures were pioneered by Fricke and von Zahn in 1985, in 1990 by She et al. at Colorado State University (CSU), with upgrades to measure both temperature and wind in 1994, and under sunlit conditions in 1996 with 24 h continuous observational capability in 2002. This paper details the assumptions and procedures for the retrieval of mesopause region temperatures, line-of-sight winds, and sodium densities from day and night signals from the CSU narrowband Na lidar.
View Article and Find Full Text PDFThe independent Office of the Actuary for CMS certified that the Pioneer ACO model has met the stringent criteria for expansion to a larger population. Significant savings have accrued and quality targets have been met, so the program as a whole appears to be working. Ironically, 13 of the initial 32 enrollees have left.
View Article and Find Full Text PDFNear-field acoustical holography methods are used to predict sound radiation from an engine installed on a high-performance military fighter aircraft. Cylindrical holography techniques are an efficient approach to measure the large and complex sound fields produced by full-scale jets. It is shown that a ground-based, one-dimensional array of microphones can be used in conjunction with a cylindrical wave function field representation to provide a holographic reconstruction of the radiated sound field at low frequencies.
View Article and Find Full Text PDFIn 1999, the U.S. Geological Survey (USGS) National Wildlife Health Center, Madison, Wisconsin, conducted a diagnostic investigation into a water bird mortality event involving intoxication with avian botulism type C and infection with avian chlamydiosis at the Benton Lake National Wildlife Refuge in Montana, USA.
View Article and Find Full Text PDFBackground: The value of arthroscopic revision shoulder stabilization after failed instability repair is still a matter of debate.
Hypothesis: Arthroscopic revision shoulder stabilization using suture anchors provides equivalent subjective and objective results compared with initial arthroscopic instability repair.
Study Design: Cohort study; Level of evidence, 3.
The Balinese gamelan gong ageng wadon produces distinct acoustic beating (called ombak) when struck. This phenomenon is explored using both acoustical and vibrometry measurements. The measurements have revealed the beating has two sources.
View Article and Find Full Text PDFWe present a technique to measure the frequency chirp introduced by the laser pulse amplification process in the transmitter of the Colorado State University sodium lidar system. This chirp causes a systematic radial wind bias that must be removed from the reported wind measurements. An iodine absorption line located near the lidar operating wavelength of 589.
View Article and Find Full Text PDFBrain tissue from 12 aborted bovine fetuses submitted to the Wisconsin Veterinary Diagnostic Laboratory revealed histologic lesions that consisted of glial nodules and variable degrees of mononuclear inflammation, microhemorrhage, neuronal necrosis, and cerebral cortical cavitation. A diagnosis of Bovine herpesvirus 1 (BHV-1) abortion had been made in all of these cases through multiple testing modalities. Brain tissue from 8 of the 12 fetuses was immunohistochemically stained with a monoclonal antibody specific to BHV-1, and, in 5 fetuses, there was positive intralesional staining of neurons, glial cells, and endothelial cells.
View Article and Find Full Text PDFStudy Design: In vitro wear simulation.
Objective: To determine the type and amount of wear produced by experimental metal-on-metal artificial discs for the lumbar spine. To minimize the amount of wear by changing the carbon content, clearance, and presence of a keel and notch.