Background: The aim of this study was to compare the outcome of implantation of a XEN45 Gel Stent with the outcome of implantation of a Preserflo MicroShunt in a matched-pair analysis in eyes being naïve to filtering surgery.
Methods: In this comparative, retrospective study, 50 eyes that had undergone XEN45 Gel Stent implantation were compared with 50 eyes after Preserflo implantation. Follow-up was at least 6 months, and surgical success was measured by criteria A (IOP < 21 mmHg, IOP reduction >20%, no repeat surgery); criteria B (IOP < 18 mmHg, IOP reduction >20%, no repeat surgery); and criteria C (IOP ≤15 mmHg, IOP reduction ≥40%, no repeat surgery).
Purpose: To determine differing outcomes among either phakic or pseudophakic patients who received standalone XEN45 Gel Stent (Allergan, an AbbVie Company, CA, USA) implantation and patients who underwent combined surgery with phacoemulsification.
Methods: This retrospective single-center study involved 180 eyes of 180 participants who underwent XEN45 Gel Stent implantation, of which 60 eyes received combined surgery with phacoemulsification (combined group). Standalone stent implantation was performed on 60 phakic (phakic group) and on 60 pseudophakic eyes (pseudophakic group).
Background: To investigate in combined iStent inject implantation with phacoemulsification carried out bilaterally, whether intraocular pressure (IOP)-lowering effectiveness in the first eye has a predictive potential for the outcome of the second eye in primary open-angle glaucoma (POAG).
Methods: This retrospective study included 72 eyes from 36 participants, who underwent trabecular bypass implantation in combination with cataract surgery at two study centres (Düsseldorf, Cologne). Surgery was classified as either 'success' or 'failure' based on three scores: IOP at follow-up <21 mmHg (Score A) or IOP < 18 mmHg (Score B), with an IOP reduction >20% respectively, without re-surgery and IOP ≤ 15 mmHg with an IOP reduction ≥40%, without re-surgery (Score C).
Aim: To analyze the therapeutic effect of combined ab-interno trabeculectomy and cataract surgery on intraocular pressure (IOP) levels in supine and sitting postures during a 24-hour IOP profile.
Methods: Twenty-six eyes of twenty-six patients receiving ab-interno trabeculectomy using electroablation of the trabecular meshwork combined with cataract surgery or stand-alone were included in this retrospective analysis. IOP change during 24-hour IOP profiles within two years postoperatively were analyzed for eyes receiving surgery ("study eyes") and compared to fellow eyes, which had not received surgery.
Introduction: We report a case of endophthalmitis and endocarditis that developed after stent perforation following a XEN45 Gel Stent implantation 10 months ago.
Case Report: A 79-year-old man was referred to our hospital because of endophthalmitis of the right eye. The patient had undergone XEN45 Gel Stent implantation in the same eye 10 months ago.
Background: To determine whether the outcome of the first eye may serve as a predictor for intraocular pressure (IOP)-lowering effectiveness in the second eye following bilateral ab interno trabeculectomy.
Methods: This retrospective single-centre study included 168 eyes from 84 participants, who underwent combined Trabectome surgery with phacoemulsification cataract surgery in a hospital setting. The clinical endpoint was defined as either 'success' or 'failure' based on four separate scores at the longest follow-up time point: IOP at follow-up <21 mm Hg (Score A) or IOP < 18 mm Hg (Score B), without re-surgery and IOP reduction >20%; IOP ≤15 mm Hg without re-surgery and IOP reduction ≥40% (Score C); and the sole absence of re-surgery according to the discretion of the surgeon (Score D).
Purpose: To analyze the longitudinal change in Bruch's membrane opening minimal rim width (BMO-MRW) and circumpapillary retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography (SD-OCT) after glaucoma surgery via ab-interno trabeculectomy in adult glaucoma patients.
Methods: Retrospective audit of 65 eyes of 65 participants undergoing ab-interno trabeculectomy using electroablation of the trabecular meshwork. In 53 eyes, surgery was combined with phacoemulsification and posterior chamber lens implantation.
Purpose: To characterize the two-dimensional parameter Bruch's membrane opening minimum rim area (BMO-MRA) in spectral domain optical coherence tomography (SD-OCT) of the optic nerve head (ONH) compared to minimum rim width (BMO-MRW) and retinal nerve fibre layer (RNFL) thickness in a large patient cohort.
Methods: Case-control, cross-sectional study of 705 eyes of 445 participants. A total of 449 eyes with glaucoma, 67 eyes with ocular hypertension and 189 healthy controls, underwent SD-OCT and confocal laser scanning tomography (CSLT), visual field testing and clinical examination.