Nitrosamine drug substance-related impurities (NDSRIs) are a sub-category of N-nitrosamine drug impurities that share structural similarity to the corresponding active pharmaceutical ingredient. The mutagenicity of NDSRIs is poorly understood. We previously tested a series of NDSRIs using the Enhanced Ames Test (EAT).
View Article and Find Full Text PDFThe mitigation of nitrosamine formation in drug products has been studied and approaches such as using formulations with pH modifiers and antioxidants have been shown to decrease the formation of nitrosamines. However, more studies are needed to explore the effectivness of mitigation strategies with different drug models and formulations. The primary objective of this work was to assess the role of different antioxidants and pH modifiers in tablet formulations to mitigate the formation of NDMA, prepared in-house, using metformin hydrochloride as a model drug.
View Article and Find Full Text PDFRegul Toxicol Pharmacol
November 2024
Accurately determining the mutagenicity of small-molecule N-nitrosamine drug impurities and nitrosamine drug substance-related impurities (NDSRIs) is critical to identifying mutagenic and cancer hazards. In the current study we have evaluated several approaches for enhancing assay sensitivity for evaluating the mutagenicity of N-nitrosamines in the bacterial reverse mutagenicity (Ames) test. Preincubation assays were conducted using five activation conditions: no exogenous metabolic activation and metabolic activation mixes employing both 10% and 30% liver S9 from hamsters and rats pretreated with inducers of enzymatic activity.
View Article and Find Full Text PDFWith the finalization of the ICH Q14 Analytical Procedure Development guideline, how to apply enhanced approaches (such as analytical quality by design (AQbD)) to develop an analytical procedure, and to propose Established Conditions (ECs) and corresponding reporting categories, is increasingly being discussed. To gain practical experience in applying an enhanced approach for method development and identifying ECs, we developed, validated, and implemented an analytical procedure for a nitrosamine drug substance-related impurity (NDSRI). Here, as an example of the application of Q12 Lifecycle Management guideline principles in regards to analytical procedures, we briefly elaborate how: 1) the principles documented in the ICH Q14 guideline for analytical procedure development were applied, with the focus on identifying an Analytical Target Profile (ATP), knowledge management and risk assessment; 2) analytical procedure robustness according to the recommendations in ICH Q2(R2) Validation of Analytical Procedure guideline and Q14, were evaluated; and 3) mass spectrometry ECs and associated proposed reporting categories were proposed.
View Article and Find Full Text PDFReformulation with addition of antioxidants is one potential mitigation strategy to prevent or reduce nitrosamine drug substance-related impurities (NDSRIs) in drug products. To explore whether there could be other approaches to demonstrate bioequivalence for a reformulated oral product, which typically needs in vivo bioequivalence studies to support the changes after approval, the effects of antioxidant on the in vitro permeability of BCS III model drug substances were investigated to see whether there could be any potential impact on drug absorption. Six antioxidants were screened and four (ascorbic acid, cysteine, α-tocopherol and propyl gallate) were selected based on their nitrosamine inhibition efficiencies.
View Article and Find Full Text PDFWith the discovery of carcinogenic nitrosamine impurities in pharmaceuticals in 2018 and subsequent regulatory requirements for risk assessment for nitrosamine formation during pharmaceutical manufacturing processes, storage or from contaminated supply chains, effective testing of nitrosamines has become essential to ensure the quality of drug substances and products. Mass spectrometry has been widely applied to detect and quantify trace amounts of nitrosamines in pharmaceuticals. As part of an effort by regulatory authorities to assess the measurement variation in the determination of nitrosamines, an inter-laboratory study was performed by the laboratories from six regulatory agencies with each of the participants using their own analytical procedures to determine the amounts of nitrosamines in a set of identical samples.
View Article and Find Full Text PDFNitrosamine compounds are classified as potential human carcinogens, the origin of these impurities can be broadly classified in two categories, nitrosamine impurity found in drug products that are not associated with the Active Pharmaceutical Ingredient (API), such as N-nitrosodimethylamine (NDMA) or nitrosamine impurities associated with the API, such as nitrosamine drug substance-related impurities (NDSRIs). The mechanistic pathway for the formation of these two classes of impurities can be different and the approach to mitigate the risk should be tailored to address the specific concern. In the last couple of years number of NDSRIs have been reported for different drug products.
View Article and Find Full Text PDFPropranolol is a widely used β-blocker that can generate a nitrosated derivative, N-nitroso propranolol (NNP). NNP has been reported to be negative in the bacterial reverse mutation test (the Ames test) but genotoxic in other in vitro assays. In the current study, we systematically examined the in vitro mutagenicity and genotoxicity of NNP using several modifications of the Ames test known to affect the mutagenicity of nitrosamines, as well as a battery of genotoxicity tests using human cells.
View Article and Find Full Text PDFControl of N-nitrosoamine impurities is important for ensuring the safety of drug products. Findings of nitrosamine impurities in some drug products led FDA to develop new guidance providing recommendations for manufacturers towards prevention and detection of nitrosamine impurities in pharmaceutical products. One of these products, ranitidine, also had a published in vivo study, which has since been retracted by its authors, suggesting a potential for in vivo conversion of ranitidine to the probable human carcinogen, N-nitrosodimethylamine (NDMA).
View Article and Find Full Text PDFN-Nitrosamines (also referred to as nitrosamines) are a class of substances, many of which are highly potent mutagenic agents which have been classified as probable human carcinogens. Nitrosamine impurities have been a concern within the pharmaceutical industry and by regulatory authorities worldwide since June 2018, when regulators were informed of the presence of N-nitrosodimethylamine (NDMA) in the angiotensin-II receptor blocker (ARB) medicine, valsartan. Since that time, regulatory authorities have collaborated to share information and knowledge on issues related to nitrosamines with a goal of promoting convergence on technical issues and reducing and mitigating patient exposure to harmful nitrosamine impurities in human drug products.
View Article and Find Full Text PDFMany nitrosamines are recognized as mutagens and potent rodent carcinogens. Over the past few years, nitrosamine impurities have been detected in various drugs leading to drug recalls. Although nitrosamines are included in a 'cohort of concern' because of their potential human health risks, most of this concern is based on rodent cancer and bacterial mutagenicity data, and there are little data on their genotoxicity in human-based systems.
View Article and Find Full Text PDFAn oil-in-water (o/w) nanoemulsion (NE), composed of oil globules, stabilized by a surfactant, and dispersed in an aqueous phase, is increasingly developed in complex drug formulation. Kinetically stable NEs are used to formulate hydrophobic drugs and typically provide higher dosage strengths and better content uniformity. However, little is known accurately about drug distribution in its multiphase solution, especially for the possible drug presence in the surfactant (s) phase, the interface layer between the dispersed oil (o) and the continuous water (w) phases.
View Article and Find Full Text PDFRecalls of some batches of metformin have occurred due to the detection of N-nitrosodimethylamine (NDMA) in amounts above the acceptable intake (AI) of 96 ng per day. Prior to the recalls, an international regulatory laboratory network had been monitoring drugs for nitrosamine impurities with each laboratory independently developing and validating multiple analytical procedures to detect and measure nitrosamines in metformin drugs used in their jurisdictions. Here, we provide an overview of the analysis of metformin active pharmaceutical ingredients (APIs) and drug products with 1090 samples (875 finished dosage forms (FDFs) and 215 API samples) tested beginning in November of 2019 through July of 2020.
View Article and Find Full Text PDFPeptide and protein drug molecules fold into higher order structures (HOS) in formulation and these folded structures are often critical for drug efficacy and safety. Generic or biosimilar drug products (DPs) need to show similar HOS to the reference product. The solution NMR spectroscopy is a non-invasive, chemically and structurally specific analytical method that is ideal for characterizing protein therapeutics in formulation.
View Article and Find Full Text PDFImportance: A publication reported that N-nitrosodimethylamine (NDMA), a probable human carcinogen, was formed when ranitidine and nitrite were added to simulated gastric fluid. However, the nitrite concentrations used were greater than the range detected in acidic gastric fluid in prior clinical studies.
Objective: To characterize NDMA formation following the addition of ranitidine to simulated gastric fluid using combinations of fluid volume, pH levels, and nitrite concentrations, including physiologic levels.
Importance: In 2019, the US Food and Drug Administration (FDA) received a citizen petition indicating that ranitidine contained the probable human carcinogen N-nitrosodimethylamine (NDMA). In addition, the petitioner proposed that ranitidine could convert to NDMA in humans; however, this was primarily based on a small clinical study that detected an increase in urinary excretion of NDMA after oral ranitidine consumption.
Objective: To evaluate the 24-hour urinary excretion of NDMA after oral administration of ranitidine compared with placebo.
Degarelix is a gonadotropin-releasing hormone (GnRH) receptor antagonist. Upon contact with physiological fluid, degarelix undergoes quick gelation and forms a depot at the site of injection providing sustained release. The molecular gelling kinetics is a critical physiochemical quality attribute of degarelix products that may impact drug delivery.
View Article and Find Full Text PDFThe N-glycosylation pattern of Asn-297 may have impacts on monoclonal antibody (mAb) drug plasma clearance, antibody-dependent cell mediated cytotoxicity (ADCC), and complement-dependent cytotoxicity (CDC). Notably, the changes in the relative abundance of certain minor glycans, like the afucosylation, high-mannose, or galactosylation are known to change mAb properties and functions. Here, a middle-down NMR spectroscopy based analytical procedure was applied to assess the composition and structure of glycans on adalimumab and trastuzumab without glycan cleavage from the mAbs.
View Article and Find Full Text PDFPurpose: Analytical methods suitable for intact drug products are often necessary to evaluate the equivalence in physicochemical properties between two drug products (DP) containing the same drug substance (DS), e.g., an innovator biologic drug and its proposed biosimilar.
View Article and Find Full Text PDF