The aim of this study was to determine the effect of the induced stress and restraint provided by the underlying bone on the frequency-dependent storage and loss stiffness (for bone restraint) or modulus (for induced stress) of articular cartilage, which characterise its viscoelasticity. Dynamic mechanical analysis has been used to determine the frequency-dependent viscoelastic properties of bovine femoral and humeral head articular cartilage. A sinusoidal load was applied to the specimens and out-of-phase displacement response was measured to determine the phase angle, the storage and loss stiffness or modulus.
View Article and Find Full Text PDFAntimicrobial silver nanoparticle coatings have attracted interest for reducing prosthetic joint infection. However, few studies report in vivo investigations of the biotransformation of silver nanoparticles within the regenerating tissue and its impact on bone formation. We present a longitudinal investigation of the osseointegration of silver nanoparticle-coated additive manufactured titanium implants in rat tibial defects.
View Article and Find Full Text PDFThis study evaluated the effect of pulsed low-intensity ultrasound on cell proliferation, collagen production and glycosaminoglycan deposition by human dermal fibroblasts encapsulated in alginate. Hoechst 33258 assay for cell number, hydroxyproline assay for collagen content, dimethylmethylene blue assay for glycosaminoglycan content and scanning electron microscopy were performed on the encapsulated cells treated with pulsed low-intensity ultrasound and a control group that remained untreated. Pulsed low-intensity ultrasound showed a significant effect on cell proliferation and collagen deposition but no consistent pattern for glycosaminoglycan content.
View Article and Find Full Text PDFJ Back Musculoskelet Rehabil
August 2016
Background: Static radiographic techniques are unable to capture the wealth of kinematic information available from lumbar spine sagittal plane motion.
Objective: Demonstration of a viable non-invasive technique for acquiring and quantifying intervertebral motion of the lumbar spine in the sagittal plane.
Methods: Videofluoroscopic footage of sagittal plane lumbar spine flexion-extension in seven symptomatic volunteers (mean age = 48 yrs) and one asymptomatic volunteer (age = 54 yrs) was recorded.
The viscoelastic properties of cylinders (diameter 5 mm, height 2.2 ± 0.2 mm) of Nagor silicone elastomer of medium hardness, were investigated before and after the specimens had undergone accelerated aging in saline solution at 70°C for 38, 76 and 114 days (to simulate aging at 37°C, for 1, 2 and 3 years, respectively).
View Article and Find Full Text PDFThe Charité(®) lumbar intervertebral disc replacement was subjected to wear testing in an electro-mechanical spine simulator. Sinusoidally varying compression (0.6-2 kN, frequency 2 Hz), rotation (±2°, frequency 1 Hz), flexion-extension (6° to -3°, frequency 1 Hz) and lateral bending (±2°, frequency 1 Hz) were applied out of phase to specimens immersed in diluted calf serum at 37 °C.
View Article and Find Full Text PDFThis study presents a method for measuring the low volumetric wear expected in ceramic total disc replacements, which can be used to replace intervertebral discs in the spine, using non-contacting optical methods. Alumina-on-alumina ball-on-disc tests were conducted with test conditions approximating those of cervical (neck region of the spine) total disc replacement wear tests. The samples were then scanned using a three-dimensional non-contacting optical profilometer and the data used to measure surface roughness and develop a method for measuring the wear volume.
View Article and Find Full Text PDFMixtures of silicone elastomer and silicone oil were prepared and the values of their Young's moduli, E, determined in compression. The mixtures had volume fractions, [Formula: see text], of silicone oil in the range of 0-0.73.
View Article and Find Full Text PDFBackground: The knee is an incongruent joint predisposed to developing osteoarthritis, with certain regions being more at risk of cartilage degeneration even in non-osteoarthrosed joints.At present it is unknown if knee regions prone to cartilage degeneration have similar storage and/or loss stiffness, and frequency-dependent trends, to other knee joint cartilage. The aim of this study was to determine the range of frequency-dependent, viscoelastic stiffness of articular cartilage across the bovine knee joint.
View Article and Find Full Text PDFProc Inst Mech Eng H
September 2013
Some designs of total disc replacement devices have articulating bearing surfaces, and these devices are tested in vitro with a lubricant of diluted calf serum. It is believed that the lubricant found in total disc replacement devices in vivo is interstitial fluid that may have properties between that in Ringer's solution and diluted calf serum. To investigate the effect of lubricants, a set of friction tests were performed on a generic model of a metal against metal ball-and-socket total disc replacement device.
View Article and Find Full Text PDFThe wear of a model metal-on-metal ball-and-socket total disc arthroplasty was measured in a simulator. The ball had a radius of 10 mm, and there was a radial clearance between ball and socket of 0.015 mm.
View Article and Find Full Text PDFThis study investigated the friction between surgical instruments and bone to aid improvements to instrument design. The bases of orthopaedic surgical instruments are usually made of metal, especially stainless steel. Silicone elastomer was chosen as an alternate biocompatible material, which would be compliant on the bone surface when used as the base of an instrument.
View Article and Find Full Text PDFProc Inst Mech Eng H
January 2012
The mineral content of cancellous bone from sheep and pig vertebral bodies was determined by ashing at 800 degrees C. The results were compared with published results for human vertebral cancellous bone. The results for sheep (0.
View Article and Find Full Text PDFIn this study, the effect of pulsed-low intensity ultrasound on cell proliferation, collagen production and glycosaminoglycan deposition by 3T3 fibroblasts encapsulated in alginate was evaluated. Hoechst 33258 assay for cell number, hydroxyproline assay for collagen content and dimethylamine blue assay for glycosaminoglycan content were performed on samples from cell cultures treated with pulsed-low intensity ultrasound and a control group. Pulsed-low intensity ultrasound shows no effect on cell proliferation, while collagen and glycosaminoglycan contents were consistently higher in the samples treated with pulsed-low intensity ultrasound, showing a statistically significant difference (p < 0.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
March 2015
A transient multi-physics model of the mitral heart valve has been developed, which allows simultaneous calculation of fluid flow and structural deformation. A recently developed contact method has been applied to enable simulation of systole (the stage when blood pressure is elevated within the heart to pump blood to the body). The geometry was simplified to represent the mitral valve within the heart walls in two dimensions.
View Article and Find Full Text PDFRepair of the mitral valve is defined (loosely) as a procedure that alters the valve structure, without replacement, enabling the natural valve itself to continue to perform under the physical conditions to which it is exposed. As the mitral valve is driven by flow and pressure, it should be feasible to analyse and assess its function, failure and repair as a mechanical system. This article reviews the current state of mechanical evaluation of surgical repairs of the failed mitral valve of the heart.
View Article and Find Full Text PDFStudy Design: Mechanical testing of total disc arthroplasty (TDA).
Objective: To compare the friction between a polymer socket-on-metal ball and metal socket-on-polymer ball TDA.
Summary Of Background Data: A degenerate intervertebral disc can be replaced by TDA.
Comput Methods Biomech Biomed Engin
April 2013
A new 2D method to implement transient contact using Comsol Multiphysics (finite element analysis software that enables multiphysics simulations) is described, which is based on Hertzian contact. This method is compared to the existing (default) contact method that does not enable real transient simulations, but instead performs steady-state solutions where time is a constant. The two types of contact modelling have been applied to simple 2D biological heart valve models, undergoing strains in the region of 10% under 20 kPa pressure (applied over 0.
View Article and Find Full Text PDFStudy Design: Twelve Cadisc-L devices were subjected to flexion (0°-6°) and extension (0° to -3°) motions at compressive loads between 500 N and 2000 N at a flexural rate between 0.25°/s and 3.0°/s.
View Article and Find Full Text PDFTotal disc arthroplasty (TDA) can be used to replace a degenerated intervertebral disc in the spine. There are different designs of prosthetic discs, but one of the most common is a ball-and-socket combination. Contact between the bearing surfaces can result in high frictional torque, which can then result in wear and implant loosening.
View Article and Find Full Text PDFAlginate hydrogels have been used widely in tissue engineering for cell encapsulation for several reasons: low toxicity, the ability to gel under gentle condition and compatibility with cells. In this study, we determined the effect of different concentrations of alginate on encapsulation of 3T3 fibroblast cells at two different cell seeding densities. Live/dead staining and MTT assay were performed at regular intervals up to 4 weeks.
View Article and Find Full Text PDFScrew fixation can be extremely difficult to achieve in osteoporotic (OP) bone because of its low strength. This study determined how pullout strength is affected by placing different bone screws at varying angles in normal and OP bone models. Pullout tests of screws placed axially, and at angles to the pullout axis (ranging from 10° to 40°), were performed in 0.
View Article and Find Full Text PDFFour medical grade silicones were swollen, until they reached equilibrium (i.e. constant mass) in eight liquids at 25 degrees C.
View Article and Find Full Text PDFBackground: Articular cartilage is a viscoelastic material, but its exact behaviour under the full range of physiological loading frequencies is unknown. The objective of this study was to measure the viscoelastic properties of bovine articular cartilage at loading frequencies of up to 92 Hz.
Methods: Intact tibial plateau cartilage, attached to subchondral bone, was investigated by dynamic mechanical analysis (DMA).
Background: Polyurethane (PU) foam is widely used as a model for cancellous bone. The higher density foams are used as standard biomechanical test materials, but none of the low density PU foams are universally accepted as models for osteoporotic (OP) bone. The aim of this study was to determine whether low density PU foam might be suitable for mimicking human OP cancellous bone.
View Article and Find Full Text PDF