Roll compaction is a commonly used dry granulation process in pharmaceutical, fine chemical and agrochemical industries for materials sensitive to heat or moisture. The ribbon density distribution plays an important role in controlling properties of granules (e.g.
View Article and Find Full Text PDFA family of highly stable (poly)perfluoroalkylated metallic nitride cluster fullerenes was prepared in high-temperature reactions and characterized by spectroscopic (MS, (19)F NMR, UV-vis/NIR, ESR), structural and electrochemical methods. For two new compounds, Sc(3)N@C(80)(CF(3))(10) and Sc(3)N@C(80)(CF(3))(12,) single crystal X-ray structures are determined. Addition pattern guidelines for endohedral fullerene derivatives with bulky functional groups are formulated as a result of experimental ((19)F NMR spectroscopy and single crystal X-ray diffraction) studies and exhaustive quantum chemical calculations of the structures of Sc(3)N@C(80)(CF(3))(n) (n = 2-16).
View Article and Find Full Text PDFSince the commercial development of modern near-infrared spectroscopy in the 1970s, analysts have almost invariably used units of weight percent as the measure of analyte concentration, due largely to the historical precedent from other analytical methods, including other spectroscopic techniques. The application of the CLS algorithm to a set of binary and ternary liquid mixtures reveals that the spectroscopic measurement sees the sample differently; that the measured absorbance spectrum is in fact sensitive to the volume fraction of the various components of the mixture. Because there is not a one-to-one relationship between volume fraction and other measures of analyte concentration, nor is the relationship linear, this has important implications for the application of both the CLS algorithm and the various other, more conventional, calibration algorithms that are commonly used.
View Article and Find Full Text PDFWe report on the delivery of low energy ultra-short (<1 ps) laser pulses for laser induced breakdown spectroscopy (LIBS). Ultra-short pulses have the advantage of high peak irradiance even at very low pulse energies. This opens the possibility to use compact, rare-earth doped fiber lasers in a portable platform for point detection applications using LIBS for elemental analysis.
View Article and Find Full Text PDFSeparation difficulties have led to a paucity of purified metallic nitride fullerenes (MNFs). Fundamental research and application development has been hampered with limited sample availability. Separation techniques designed to remove contaminant empty-cage fullerenes (e.
View Article and Find Full Text PDFSurface-enhanced Raman spectra (SERS) of molecules separated by gas chromatography (GC) were measured off-line by condensing the analyte on a moving, liquid-nitrogen-cooled ZnSe window on which a 5 nm layer of silver had been formed by physical vapor deposition. After the components that eluted from the chromatograph had been deposited, the substrate was allowed to warm up to room temperature and transferred to the focus of a Raman microspectrometer where the spectrum of each component was measured. Band intensities in the spectrum of 3 ng of caffeine prepared in this way were approximately the same as in the spectrum of bulk caffeine.
View Article and Find Full Text PDFEven though the interface of gas chromatography (GC) and mass spectrometry (MS) is by far the most popular way of identifying molecules eluting from a GC in real time, the identification of compositional isomers by MS is equivocal at best. Much better results would be found by infrared spectrometry (IR) if the sensitivity of the GC/IR interface could be improved. In this paper, we show how the smallest quantity of molecules injected into a GC for which an identifiable infrared spectrum can be measured on-line has been reduced by a factor of 10 below the detection limit of the most sensitive current technique.
View Article and Find Full Text PDF