Publications by authors named "David Chafin"

Developing a reproducible and secure supply of customizable control tissues that standardizes for the cell type, tissue architecture, and preanalytics of interest for usage in applications including diagnostic, prognostic, and predictive assays, is critical for improving our patient care and welfare. The conventionally adopted control tissues directly obtained from patients are not ideal because they oftentimes have different amounts of normal and neoplastic elements, differing cellularity, differing architecture, and unknown preanalytics, in addition to the limited supply availability and thus associated high costs. In this study, we demonstrated a strategy to stably produce tissue-mimics for diagnostics purposes by taking advantage of the three-dimensional (3D) bioprinting technology.

View Article and Find Full Text PDF

This work investigates whether changes in a biospecimen's molecular composition from formaldehyde fixation drive changes in the mid infrared (MID-IR) spectrum. Our ultimate goal was to develop an analytical metrology that could be used to accurately determine the fixation time of a tissue sample as a surrogate to overall tissue quality. Multiple unstained formalin-fixed paraffin-embedded tissue samples were scanned with an MID-IR microscope to identify a molecular fingerprint of formaldehyde fixation.

View Article and Find Full Text PDF

Modern histopathology is built on the cornerstone principle of tissue fixation, however there are currently no analytical methods of detecting fixation and as a result, in clinical practice fixation is highly variable and a persistent source of error. We have previously shown that immersion in cold formalin followed by heated formalin is beneficial for preservation of histomorphology and have combined two-temperature fixation with ultra-sensitive acoustic monitoring technology that can actively detect formalin diffusing into a tissue. Here we expand on our previous work by developing a predictive statistical model to determine when a tissue is properly diffused based on the real-time acoustic signal.

View Article and Find Full Text PDF

Phosphoproteins are the key indicators of signaling network pathway activation. Many disease treatment therapies are designed to inhibit these pathways and effective diagnostics are required to evaluate the efficacy of these treatments. Phosphoprotein IHC have been impractical for diagnostics due to inconsistent results occurring from technical limitations.

View Article and Find Full Text PDF

Precision tissue diagnostics rely on high quality input specimens so that assay results are not affected by artifact, but advances in collection and processing of tissue specimens have lagged behind innovations in diagnostic assay development. Therefore, we have designed and evaluated a novel surgical tissue collection device that maintains and monitors sample temperature and motion throughout transport so that the major preanalytical variable of tissue temperature can be controlled and measured. This device, in combination with an improved cold-hot tissue fixation protocol affords optimal biomarker preservation in less overall time, thereby simultaneously improving diagnostic quality and turnaround time.

View Article and Find Full Text PDF

The development of precision testing for disease diagnosis has advanced medicine by specifically matching patients with drugs to treat specific diseases. High-quality diagnostics start with high-quality tissue specimens. The development and optimization of tissue handling and processing have lagged behind bioassay development.

View Article and Find Full Text PDF

Purpose Of Review: Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions.

View Article and Find Full Text PDF

Personalized medicine promises diagnosis and treatment of disease at the individual level and relies heavily on clinical specimen integrity and diagnostic assay quality. Preanalytics, the collection and handling steps of a clinical specimen before immunohistochemistry or other clinical assay, are critically important to enable the correct diagnosis of disease. However, the effects of preanalytics are often overlooked due to a lack of standardization and limited assessment tools to quantify their variation.

View Article and Find Full Text PDF

The preservation of certain labile cancer biomarkers with formaldehyde-based fixatives can be considerably affected by preanalytical factors such as quality of fixation. Currently, there are no technologies capable of quantifying a fixative's concentration or the formation of cross-links in tissue specimens. This work examined the ability to detect formalin diffusion into a histological specimen in real time.

View Article and Find Full Text PDF

Modern pathology is built around the principle of preserving tissues such that the in vivo molecular status is maintained at levels representative of the disease state. Tissues are immersed in a solution of fixative which slowly inactivates biological activities, thus preserving the sample. Further processing ultimately allows the tissue to be embedded into wax for thin sectioning and staining for interpretation microscopically.

View Article and Find Full Text PDF

Phosphorylated signaling molecules are biomarkers of cancer pathophysiology and resistance to therapy, but because phosphoprotein analytes are often labile, poorly controlled clinical laboratory practices could prevent translation of research findings in this area from the bench to the bedside. We therefore compared multiple biomarker and phosphoprotein immunohistochemistry (IHC) results in 23 clinical colorectal carcinoma samples after either a novel, rapid tissue fixation protocol or a standard tissue fixation protocol employed by clinical laboratories, and we also investigated the effect of a defined post-operative "cold" ischemia period on these IHC results. We found that a one-hour cold ischemia interval, allowed by ASCO/CAP guidelines for certain cancer biomarker assays, is highly deleterious to certain phosphoprotein analytes, specifically the phosphorylated epidermal growth factor receptor (pEGFR), but shorter ischemic intervals (less than 17 minutes) facilitate preservation of phosphoproteins.

View Article and Find Full Text PDF

Formalin fixation is a mainstay of modern histopathologic analysis, yet the practice is poorly standardized and a significant potential source of preanalytical errors. Concerns of workflow and turnaround time drive interest in developing shorter fixation protocols, but rapid protocols can lead to poor histomorphology or inadequate downstream assay results. Additionally, assays such as immunohistochemistry for phosphorylated epitopes have historically been challenging in the context of formalin-fixed tissue, indicating that there may be room for improvement in this process that is fundamental to the practice of anatomic pathology.

View Article and Find Full Text PDF

The nucleosome and other chromatin complexes are examples of complicated protein-DNA assemblies that are not easily studied by traditional structural methods. Site-directed cleavage of DNA is a method for mapping the location of interaction of a specific site in a protein such as a linker histone within a large complex such as the nucleosome. In this chapter we describe the application of the site-directed cleavage method, employing linker histones site-specifically modified with the chemical cleavage reagent Fe(II)(EDTA-2-aminoethyl) 2-pyridyl disulfide (ebr).

View Article and Find Full Text PDF

Flap Endonuclease 1 (FEN1) plays important roles both in DNA replication and in base excision repair (BER). However, in both processes FEN1 substrates are likely to be assembled into chromatin. In order to examine how FEN1 is able to work within chromatin, we prepared model nucleosome substrates containing FEN1-cleavable DNA flaps.

View Article and Find Full Text PDF

Repeat sequences in various genomes undergo expansion by poorly understood mechanisms. By using an oligonucleotide system containing such repeats, we recapitulated the last steps in Okazaki fragment processing, which have been implicated in sequence expansion. A template containing either triplet or tandem repeats was annealed to a downstream primer containing complementary repeats at its 5'-end.

View Article and Find Full Text PDF