Objective: Our study aimed to evaluate if an extubation protocol for all post-operative cardiac patients in the cardiothoracic intensive care unit using intermittent bilevel positive airway pressure (BiPAP) could reduce the rate of re-intubation.
Methods: A total of 1,718 patients undergoing cardiac surgery from May 2012 to April 2016 were analyzed. Patients from May 2014 to April 2016 were included in a post-extubation BiPAP therapy protocol that included one hour of BiPAP followed by three hours of a nasal cannula for 24 hours after extubation in the cardiothoracic intensive care unit.
Objective: Acute respiratory failure is complicated by acidosis and altered end-organ perfusion. NOVA-LUNG iLA is an interventional lung assist (ILA) device for arteriovenous carbon dioxide removal (AVCO2R). The present study was conducted to evaluate the device for short-term CO2 removal performance and hemodynamic response.
View Article and Find Full Text PDFSurg Clin North Am
December 2005
Americans over age 65 represent the fastest growing segment of the United States population. As a result, the demographic landscape of America is changing. Knowledge of aged physiology is necessary to construct a risk-benefit analysis tailored for each patient to improve perioperative outcomes and lower the morbidity and mortality rates among the elderly.
View Article and Find Full Text PDFWe are developing an ultra compact gas exchanger to allow ambulation during arterial-venous CO2 removal (AVCO2R). The ambulatory AVCO2R gas exchanger (135 ml prime volume and 1.3 M2 gas exchange surface area) is made of polymethylpentene hollow fibers.
View Article and Find Full Text PDFPneumothorax is a frequent and potentially fatal complication of mechanical ventilation in patients with acute respiratory distress syndrome (ARDS). Prompt recognition and treatment of pneumothoraces is necessary to minimize morbidity and mortality. The radiologic and clinical signs of pneumothoraces in ARDS patients may have unusual and subtle features.
View Article and Find Full Text PDFObjective: Intermittent pneumatic compression (IPC) devices prevent lower-extremity deep venous thrombosis (LEDVT) when used properly, but compliance remains an issue. Devices are frequently discontinued when patients are out of bed, and they are rarely used in emergency departments. Trauma patients are at high risk for LEDVT; however, IPCs are underused in this population because of compliance limitations.
View Article and Find Full Text PDFPersistent air leaks are caused by the failure of the postoperative lung to achieve a configuration that is physiologically amenable to healing. The raw pulmonary surface caused by the dissection of the fissure often is separated from the pleura, and the air leak fails to close. Additionally, higher air flow thorough an alveolar-pleural fistula seems to keep the fistula open.
View Article and Find Full Text PDF