Publications by authors named "David B Dyke"

Background: Despite positive associations with rejection, the clinical value of B-type natriuretic peptide (BNP) monitoring in heart transplant recipients has not been established. We sought to determine the predictive value of changes in serial BNP level for identifying patients with acute allograft rejection.

Methods: BNP, hemodynamics and biopsies were obtained for 205 transplant recipients who underwent a total of 4,007 endomyocardial biopsy procedures.

View Article and Find Full Text PDF

Background: The ubiquitin proteasome system maintains a dynamic equilibrium of proteins and prevents accumulation of damaged and misfolded proteins, yet its role in human cardiac dysfunction is not well understood. The present study evaluated ubiquitin proteasome system function in human heart failure and hypertrophic cardiomyopathy (HCM).

Methods And Results: Proteasome function was studied in human nonfailing donor hearts, explanted failing hearts, and myectomy samples from patients with HCM.

View Article and Find Full Text PDF

Objective: Few studies have examined the association between procedural volume and clinical outcomes in heart transplantation. This retrospective study was performed on a contemporary cohort of heart transplant recipients to better elucidate the effect of transplant center volume on 1-year mortality.

Methods: Data from the Scientific Registry of Transplant Recipients were used to analyze the relationship between transplant center volume and short-term survival.

View Article and Find Full Text PDF

Background: We report the first comprehensive analysis of gene expression differences by sex and age in left ventricular samples from 102 patients with dilated cardiomyopathy.

Methods And Results: Gene expression data (HG-U133A gene chip, Affymetrix) were analyzed from 30 females and 72 males from 3 separate centers. More than 1800 genes displayed sexual dimorphism in the heart (adjusted P value <0.

View Article and Find Full Text PDF

Background: The effects of continuous blood flow and reduced pulsatility on major organ function have not been studied in detail.

Methods And Results: We evaluated renal (creatinine and blood urea nitrogen) and hepatic (aspartate transaminase, alanine transaminase, and total bilirubin) function in 309 (235 male, 74 female) advanced heart failure patients who had been supported with the HeartMate II continuous-flow left ventricular assist device for bridge to transplantation. To determine whether patients with impaired renal and hepatic function improve over time with continuous-flow left ventricular assist device support or whether there are any detrimental effects in patients with normal organ function, we divided patients into those with above-normal and normal laboratory values before implantation and measured blood chemistry over time during left ventricular assist device support.

View Article and Find Full Text PDF

Background: Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied.

Methods And Results: Thirty-four patients undergoing implantation with a pulsatile, volume displacement pump operating in a full-to-empty cycle (HeartMate XVE; Thoratec Inc, Pleasanton, Calif; n=16) or continuous-flow rotary pump with an axial design operating at a fixed rotor speed (HeartMate II; Thoratec Inc; n=18) were evaluated with right heart catheterization and echocardiography preoperatively and at 3 months postoperatively and cardiopulmonary exercise testing 3 months postoperatively.

View Article and Find Full Text PDF

Predicting end-of-life for left ventricular assist devices is important to determine timing of device removal. A retrospective analysis was performed on 46 patients undergoing implantation of the latest HeartMate XVE from July 1, 2003, through March 31, 2006. Devices were assessed by analysis of motor current waveforms and quantification of the titanium or copper particles within dust localized to the driveline vent filter by optical, polarized light, scanning electron microscopy, and energy dispersive x-ray spectroscopy.

View Article and Find Full Text PDF

Background: Serum brain natriuretic peptide (BNP) has been reported to be elevated in heart transplant recipients with both cellular and vascular rejection. Whether BNP can be used to help predict the severity of rejection is not well established.

Methods: We analyzed serial BNP measurements obtained during endomyocardial biopsy procedures in consecutive heart transplant patients occurring >45 days after transplantation.

View Article and Find Full Text PDF

Over the past decade, immunosuppression therapy has undergone striking changes in the scale and pace by which new immunosuppressive molecules and antibodies have become incorporated into daily transplant medicine. An organ-by-organ review of data reveals several trends. The highest use of induction therapy (over 70% of patients) was reported for simultaneous pancreas kidney (SPK) and pancreas after kidney (PAK) transplants in 2002; use of induction therapy was less common in liver transplants (only 18%).

View Article and Find Full Text PDF

We present 2 cases of vancomycin-resistant Enterococcus faecium mediastinitis associated with left ventricular assist devices in the setting of heart transplantation. Despite complicated operative courses and deep infection secondary to antimicrobial resistant organisms, both patients were successfully treated and have remained infection free in the long term.

View Article and Find Full Text PDF

Background: In an animal model, stretch was shown to induce myocardial tumor necrosis factor-alpha (TNF-alpha) expression. The purposes of this study were to determine whether the left ventricular (LV) volume overload that occurs in patients with chronic mitral regurgitation (MR) can induce myocardial and systemic TNF-alpha expression and whether there is a relationship between TNF-alpha expression and LV remodeling.

Methods And Results: Plasma TNF-alpha and its receptors were measured before mitral valve (MV) repair surgery in 26 MR patients and 23+/-12 months after MV repair surgery in 9 MR patients.

View Article and Find Full Text PDF

Infection remains a serious complication of left ventricular assist device (LVAD) implantation. We performed a cohort study to assess infections among patients who underwent LVAD implantation from October 1996 through May 1999. Thirty-six LVADs were implanted in 35 patients; the mean duration (+/- standard deviation) of LVAD use was 73+/-60 days (total for all patients, 2565 days).

View Article and Find Full Text PDF

Objectives: We sought to determine the survival experiences of patients bridged to heart transplantation with either intravenous (IV) inotropes or an implantable left ventricular assist device (LVAD).

Background: Because of the operative risks of LVAD implantation and the reported lower mortality associated with inotropic therapy, bridging to heart transplantation with inotropes is thought to be the preferred treatment option.

Methods: Between April 1, 1996, and May 10, 2001, a total of 104 patients were bridged to heart transplantation with either IV inotropes (n = 38) or an implantable LVAD (n = 66; HeartMate).

View Article and Find Full Text PDF

Background: Pravastatin and simvastatin prolong survival and reduce transplant-related coronary vasculopathy, although low-density lipoprotein (LDL) lowering with these agents is only modest. The objective of this study was to assess the safety of moderate dose atorvastatin and its efficacy when prior treatment with another statin had failed to lower LDL to < 100 mg/dl.

Methods: Data from 185 patients were retrospectively evaluated for adverse events, duration of exposure (person-days), and the mean atorvastatin dose exposure.

View Article and Find Full Text PDF