Publications by authors named "David Armbruster"

Battlefield wounds are at high risk of infection due to gross contamination and delays in evacuation from forward-deployed locations. The aim of this study was to formulate an antibiotic wound gel for application by a field medic in austere environments to protect traumatic wounds from infection during transport. Formulation development was conducted over multiple phases to meet temperature, handling, in vitro elution, and in vivo tissue response requirements.

View Article and Find Full Text PDF

Antimicrobial strategies for musculoskeletal infections are typically first developed with in vitro models. The In Vitro Section of the 2023 Orthopedic Research Society Musculoskeletal Infection international consensus meeting (ICM) probed our state of knowledge of in vitro systems with respect to bacteria and biofilm phenotype, standards, in vitro activity, and the ability to predict in vivo efficacy. A subset of ICM delegates performed systematic reviews on 15 questions and made recommendations and assessment of the level of evidence that were then voted on by 72 ICM delegates.

View Article and Find Full Text PDF

Error methods - compared with uncertainty methods - offer simpler, more intuitive and practical procedures for calculating measurement uncertainty and conducting quality assurance in laboratory medicine. However, uncertainty methods are preferred in other fields of science as reflected by the guide to the expression of uncertainty in measurement. When laboratory results are used for supporting medical diagnoses, the total uncertainty consists only partially of analytical variation.

View Article and Find Full Text PDF

At the start of the twenty-first century, a dramatic change occurred in the clinical laboratory community. Concepts from Metrology, the science of measurement, began to be formally applied to clinical laboratory field methods, resulting in a new appreciation of metrological calibrator traceability. It is a change because clinical laboratories test complex patient samples, for example, whole blood, serum, plasma, urine, and so forth, using commercial assay systems, not reference methods, and patient samples are tested once, not in replicate.

View Article and Find Full Text PDF

For more than a decade there has been a global effort to harmonise all phases of the testing process, with particular emphasis on the most frequently utilised measurands. In addition, it is recognised that calculated parameters derived from these measurands should also be a target for harmonisation. Using data from the Aussie Normals study we report reference intervals for three calculated parameters: serum osmolality, serum anion gap and albumin-adjusted serum calcium.

View Article and Find Full Text PDF
Article Synopsis
  • The IFCC Committee conducted a global study to create harmonized reference intervals (RIs) for medical testing, examining variations in reference values (RVs) across different countries.
  • The study involved 12 countries and over 13,000 healthy adults, measuring 50 different analytes to determine RIs through multiple statistical methods.
  • Results revealed significant differences in RVs among countries, particularly influenced by factors like nutritional status and BMI, suggesting a need for further validation to ensure accurate medical assessments.
View Article and Find Full Text PDF

Objective: Thyroid disease can be subtle in its presentation, and TSH reference intervals may be artefactually increased by including persons with subclinical thyroid disease. We have therefore used a thyroid disease-free population to determine TSH and fT4 reference intervals.

Design: Apparently healthy subjects were assessed by health questionnaire, drug history, clinical assessment and measurement of thyroid antibodies.

View Article and Find Full Text PDF
Article Synopsis
  • * A study involving 1,917 healthy children assessed 14 biochemical markers using specific methods, leading to age and gender-dependent reference intervals tailored for various age groups.
  • * Findings revealed significant variations in marker concentrations, necessitating distinct age partitions and, in some cases, gender partitions, which will enhance the evaluation of pediatric patients in lab settings.
View Article and Find Full Text PDF

Objective: Measurement of total and direct bilirubin is routinely performed for the differential diagnosis of hyperbilirubinemias. The diagnostic efficiency of a test is dependent on the chosen clinical decision limit. This study is designed to address the clinical decision limits for direct bilirubin.

View Article and Find Full Text PDF

The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies.

View Article and Find Full Text PDF

Background: Cancer biomarkers are commonly used in pediatrics to monitor cancer progression, recurrence, and prognosis, but pediatric reference value distributions have not been well established for these markers. The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) sought to develop a pediatric database of covariate-stratified reference value distributions for 11 key circulating tumor markers, including those used in assessment of patients with childhood or adult cancers.

Methods: Healthy community children from birth to 18 years of age were recruited to participate in the CALIPER project with informed parental consent.

View Article and Find Full Text PDF

Background: The utility of HbA1c for the diagnosis of type 2 diabetes requires an accurate, precise and robust test measurement system. Currently, immunoassay and HPLC are the most popular methods for HbA1c quantification, noting however the limitations associated with some platforms, such as imprecision or interference from common hemoglobin variants. Abbott Diagnostics has introduced a fully automated direct enzymatic method for the quantification of HbA1c from whole blood on the ARCHITECT chemistry system.

View Article and Find Full Text PDF

Background: Many different cystatin C-based equations exist for estimating glomerular filtration rate. Major reasons for this are the previous lack of an international cystatin C calibrator and the nonequivalence of results from different cystatin C assays.

Methods: Use of the recently introduced certified reference material, ERM-DA471/IFCC, and further work to achieve high agreement and equivalence of 7 commercially available cystatin C assays allowed a substantial decrease of the CV of the assays, as defined by their performance in an external quality assessment for clinical laboratory investigations.

View Article and Find Full Text PDF

Asian, Siberian, and American ginseng are known to interfere with serum digoxin measurements using fluorescence polarization technology, Digoxin II and Digoxin III assays (Abbott Laboratories, Green oaks, IL) as well as other digoxin assays. Abbott Laboratories more recently launched two new digoxin assays: iDigoxin, a chemiluminescent microparticle immunoassay for application on the ARCHITECT i1000SR and i2000SR immunoassay analyzers, and cDigoxin, a particle-enhanced turbidimetric inhibition immunoassay for application on the ARCHITECT c4000, c8000, and c1600 clinical chemistry analyzers; and we studied potential interferences of ginsengs with these two assays in vitro. When aliquots of drug-free serum pool treated with activated charcoal were supplemented with extracts of various ginsengs, no significant apparent digoxin values were observed.

View Article and Find Full Text PDF

Background: Pediatric endocrinopathies are commonly diagnosed and monitored by measuring hormones of the hypothalamic-pituitary-gonadal axis. Because growth and development can markedly influence normal circulating concentrations of fertility hormones, accurate reference intervals established on the basis of a healthy, nonhospitalized pediatric population and that reflect age-, gender-, and pubertal stage-specific changes are essential for test result interpretation.

Methods: Healthy children and adolescents (n = 1234) were recruited from a multiethnic population as part of the CALIPER study.

View Article and Find Full Text PDF

Background: Reference intervals are indispensable in evaluating laboratory test results; however, appropriately partitioned pediatric reference values are not readily available. The Canadian Laboratory Initiative for Pediatric Reference Intervals (CALIPER) program is aimed at establishing the influence of age, sex, ethnicity, and body mass index on biochemical markers and developing a comprehensive database of pediatric reference intervals using an a posteriori approach.

Methods: A total of 1482 samples were collected from ethnically diverse healthy children ages 2 days to 18 years and analyzed on the Abbott ARCHITECT i2000.

View Article and Find Full Text PDF

Testing quality control samples is routine in the clinical laboratory but typically these are precision controls that monitor only the reproducibility (random error) of an assay and not trueness/bias (systematic error). To assess bias, accuracy controls that address both systematic error (trueness) and random error (precision) are needed. A properly prepared trueness control can be used to assess both bias and precision, as accuracy is defined by both random and systematic error.

View Article and Find Full Text PDF

Messenger RNA encoded signals that are involved in programmed -1 ribosomal frameshifting (-1 PRF) are typically two-stemmed hairpin (H)-type pseudoknots (pks). We previously described an unusual three-stemmed pseudoknot from the severe acute respiratory syndrome (SARS) coronavirus (CoV) that stimulated -1 PRF. The conserved existence of a third stem-loop suggested an important hitherto unknown function.

View Article and Find Full Text PDF

Background: Defining reference intervals is a major challenge because of the difficulty in recruiting volunteers to participate and testing samples from a significant number of healthy reference individuals. Historical literature citation intervals are often suboptimal because they're be based on obsolete methods and/or only a small number of poorly defined reference samples.

Methods: Blood donors in Hong Kong gave permission for additional blood to be collected for reference interval testing.

View Article and Find Full Text PDF

Background: Pediatric healthcare is critically dependent on the availability of accurate and precise laboratory biomarkers of pediatric disease, and on the availability of reference intervals to allow appropriate clinical interpretation. The development and growth of children profoundly influence normal circulating concentrations of biochemical markers and thus the respective reference intervals. There are currently substantial gaps in our knowledge of the influences of age, sex, and ethnicity on reference intervals.

View Article and Find Full Text PDF

Objective: To evaluate biocompatibility of biodegradable sleeves containing antimicrobial agents, designed for local drug delivery to prevent implant-related infection.

Study Design: Synthetic polyester sleeves (a copolymer of glycolide, caprolactone, trimethylene carbonate, lactide) were cast as thin films. The antimicrobial agents incorporated in the sleeves included gentamicin sulfate, triclosan, or a combination of these drugs.

View Article and Find Full Text PDF

Background: Owing to the lack of an internationally recognized tacrolimus reference material and reference method, current LC-MS and immunoassay test methods used to monitor tacrolimus concentrations in whole blood are not standardized. The aim of this study was to assess the need for tacrolimus assay standardization.

Methods: We sent a blinded 40-member whole-blood tacrolimus proficiency panel (0-30 μg/L) to 22 clinical laboratories in 14 countries to be tested by the following assays: Abbott ARCHITECT (n = 17), LC-MS (n = 9), and Siemens Dade Dimension (n = 5).

View Article and Find Full Text PDF

Spironolactone, which is metabolized to canrenone, is often used in combination with digoxin. Potassium canrenoate is a similar drug that is also metabolized to canrenone. As a result of reported interference of spironolactone, potassium canrenoate, and their common metabolite canrenone with digoxin immunoassays, we investigated potential interference of these compounds with two relatively new digoxin assays for application on ARCHITECT clinical chemistry platforms (cDig, particle-enhanced turbidimetric inhibition immunoassay) and ARCHITECT immunoassay platforms (iDig, chemiluminescent microparticle immunoassay), both from Abbott Diagnostics.

View Article and Find Full Text PDF