Systemic uptake of perchlorate anion, a rocket fuel component and potential thyroid function disruptor, by leafy vegetables and other crops grown in contaminated waters is a public health concern. A column-switching anion-exchange chromatographic method with suppressed conductivity detection, described in this paper, achieved a 3-6 microg/kg method limit of quantitation in analysis of the wet weight edible portion of cantaloupe, carrots, lettuce, and spinach samples with field-incurred perchlorate. A test portion was blended with dilute nitric acid, and the extract was filtered under vacuum.

View Article and Find Full Text PDF

A rapid, sensitive, and specific method was developed for determining perchlorate anion in lettuce, cantaloupe, bottled water, and milk. A test portion of chopped crop homogenate was extracted with diluted nitric acid and filtered. Milk proteins were precipitated with acetonitrile, and the supernatant, after centrifugation, was cleaned up on a graphitized carbon solid-phase extraction column.

View Article and Find Full Text PDF

The arsenic, cadmium, mercury, and lead contents of 95 dietary supplement products were determined using microwave digestion and high-resolution inductively coupled plasma mass spectrometry. Precision and accuracy were demonstrated by element recovery from 17 dietary supplements and replicates of 8 reference materials. The concentration ranges were as follows: arsenic, <5-3770 microg/kg; cadmium, <10-368 microg/kg; mercury, <80-16800 microg/kg; and lead, <20-48600 microg/kg.