Publications by authors named "Dasandi Bhavesh"

A highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of tadalafil (TAD) in human plasma. TAD and its deuterated internal standard (IS), tadalafil-d3, were extracted from 200 µL plasma using Phenomenex Strata-X-C 33 µ extraction cartridges. Chromatographic analysis was carried out on Synergi™ Hydro-RP C (100 mm × 4.

View Article and Find Full Text PDF

A highly sensitive, rapid and rugged liquid chromatography-tandem mass spectrometry (LC-ESI-MS/MS) method was developed for reliable estimation of amantadine (AMD), an antiviral drug in human plasma. The analyte and internal standard (IS), amantadine-d6 (AMD-d6), were extracted from 200 µL plasma by solid phase extraction on Phenomenex Strata-X-C 33 µ cartridges. Chromatography was performed on Synergi™ Hydro-RP C (150 mm × 4.

View Article and Find Full Text PDF

A rapid, specific and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the determination of penciclovir in human plasma. The method involved simple, one-step SPE procedure coupled with a C(18) , 75 × 4.mm, 3 µm column with a flow-rate of 0.

View Article and Find Full Text PDF

A rapid, sensitive and rugged solid-phase extraction ultraperformance liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for determination of oseltamivir phosphate (OP) and oseltamivir carboxylate (OC) in human plasma. The procedure for sample preparation includes a simple SPE extraction procedure coupled with a Chromatopack C(18) column (50 × 3.0 mm, i.

View Article and Find Full Text PDF

A rapid and sensitive high-performance liquid chromatography and electrospray tandem mass spectrometry method was developed and validated for estimation of fulvestrant in rabbit plasma using liquid-liquid extraction. The separation and quantification of fulvestrant were achieved by reverse-phase chromatography on a Sunfire C18 column (50 x 2.1.

View Article and Find Full Text PDF

A rapid, specific and sensitive ultra-performance liquid chromatography tandem mass spectrometry method was developed for the determination of fenofibric acid in human plasma. The method involves simple, one-step liquid-liquid extraction procedure coupled with an Acquity UPLC(TM) BEH C(18) column (50 x 2.1 mm, i.

View Article and Find Full Text PDF

A high throughput and specific method using ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of diltiazem and its two metabolite (N-desmethyldiltiazem and O-desacetyldiltiazem) in human plasma. A one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether (MTBE) involved for the extraction of diltiazem (DLTZ), metabolites (DMeD and DAcD) and internal standard. Analytes were chromatographed on a ACQUITY UPLC BEH C(18) column (100 mm x 2.

View Article and Find Full Text PDF

A novel, specific and sensitive ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the simultaneous determination of quinapril and its active metabolite quinaprilat in human plasma. The method involves a simple, one-step extraction procedure coupled with an Acquity UPLC BEH C(18 )column (100 x 2.1 mm, i.

View Article and Find Full Text PDF

A simple and rapid HPLC assay method for the estimation of meloxicam in plasma was developed. The method totally eliminated the solvent extraction procedure. The plasma proteins were precipitated using perchloric acid (70%) and acetonitrile mixture (1:1 v/v) and the supernatant was directly injected to the HPLC system.

View Article and Find Full Text PDF