Int J Environ Res Public Health
December 2019
Comparison is an important role in the quality control and quality assurance for any measuring system. Due to the future legal regulations regarding radon levels in the air, maintaining the system quality and harmonization of results as well as validation of radon and thoron measuring systems is important. The aim of this work is to validate the degrees of equivalence and measurement precisions of the existing five radon and four thoron measuring systems located in four Asian countries (China, India, Japan and Thailand) through comparison experiment.
View Article and Find Full Text PDFA walk-in type 222Rn calibration chamber of volume 22.7 m3, which has traceability to international standards, is established at the Centre for Advanced Research in Environmental Radioactivity, Mangalore University, India. It has a human-machine interface communication system, a programmable logic controller and sensor feedback circuit for controlling and data acquisition of relative humidity (RH) and temperature (T).
View Article and Find Full Text PDFRadiat Prot Dosimetry
October 2019
Elevated levels of natural background radiation due to scattered patches of monazite sand around the beaches of Mangalore, India, have been reported earlier. A comparative study of gamma dose rates was performed in both normal background and high natural background radiation areas around Mangalore using different types of portable gamma dosimeters. In addition to this, gamma-ray energy spectra were acquired, in situ, using a NaI(Tl) based portable gamma spectrometer.
View Article and Find Full Text PDFAs part of ongoing efforts to develop the data base required for the gamma dose rate baseline in Kuwait, a survey of ambient outdoor gamma-ray dose rates was carried out in 112 locations within the country. Measurements were performed, during the period from August 2013 to March 2016, in various undisturbed open areas in the desert using a NaI dosimeter/spectrometer. The dose rates were recorded along with the corresponding gamma-ray spectra for in-situ relative contribution of the primordial radionuclides and Cs in the outdoor environment.
View Article and Find Full Text PDFA survey of indoor gamma dose rates was carried out in Kuwait using a NaI dosimeter/spectrometer. The measurements started from May 2013 until April 2015 and covered different locations within 200 dwellings: 158 halls, 26 rooms, 17 basements, and 43 kitchens (total of 244 locations). Alongside the dose rate measurements, gamma-ray spectra were also acquired to evaluate the relative contributions of K, Bi, and Tl and check the presence of Cs.
View Article and Find Full Text PDFA study on absorption of radon by different edible oils of plant origins produced and used in India was conducted in order to identify efficient radon-absorbing oils. A comparative study of radon absorption by edible oils of India with that of olive oil, which is known as a good absorber of radon, was also carried out. The study was performed by bubbling known concentrations of radon through the oil contained in a bottle and then evaluating the bubbled oil by gamma-ray spectrometry using an HPGe detector.
View Article and Find Full Text PDFAppl Radiat Isot
August 2008
Slow coincidence circuits for the anti-coincidence measurements have been considered for use in Compton suppression technique. The simplified version of the slow circuit has been found to be fast enough, satisfactory and allows an easy system setup, particularly with the advantage of the automatic threshold setting of the low-level discrimination. A well-type NaI detector as the main detector surrounded by plastic guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit.
View Article and Find Full Text PDFIndoor radon measurements were carried out in 300 dwellings in Kuwait using duplicate sets of charcoal detectors. Measurements were made at three different locations in the dwellings: living rooms, bedrooms, and basements. The results show that the radon concentration in the dwellings of Kuwait was found to vary in the range of 4.
View Article and Find Full Text PDFThe feasibility of using small quantities of activated charcoal and a 7.6 cm x 7.6 cm NaI(Tl) well-type detector was investigated for indoor radon measurements.
View Article and Find Full Text PDF