Thirty-one drinking water storage tank sediment samples were collected in 13 states, 17 distribution systems, and 29 tanks over the course of 4 years. Sediment samples were characterized for elemental composition and physical properties, which were found to be inconsistent both between samples of the same distribution system and across geographical regions. Differences between samples from the same tank also indicated spatial differences in sediment composition within storage tanks.

View Article and Find Full Text PDF

Orthophosphate (PO) is a commonly used corrosion control treatment to reduce lead (Pb) concentrations in drinking water. PO reduces Pb concentrations by forming relatively insoluble lead phosphate (Pb-PO) minerals. In some cases, however, Pb-PO minerals have been observed to form nanoparticles, and if suspended in water, these nanoparticles can be mobile and reach consumer taps.

View Article and Find Full Text PDF

Ductile iron and copper coupons were aged 137-189 days and 2 days, respectively, with 2 mg Cl L monochloramine under four water chemistries (pH 7 or 9 and 0 or 3 mg L orthophosphate). Subsequently, microelectrode profiles of monochloramine concentration, oxygen concentration, and pH were measured from the bulk water to near the coupon reactive surface, allowing estimation of flux and apparent surface reaction rate constants for monochloramine and oxygen. Both metals showed similar trends with orthophosphate where orthophosphate decreased metal reactivity with monochloramine (pH 9) and oxygen (pH 7).

View Article and Find Full Text PDF

Chloraminated drinking water systems commonly use free chlorine conversions (FCCs) to prevent or control nitrification, but unintended water quality changes may occur, including increased disinfection by-product and metal concentrations. This study evaluated water quality in a chloraminated drinking water system and residential locations before, during, and after their annual, planned FCC. Water quality alternated between relatively consistent and variable periods when switching disinfectants.

View Article and Find Full Text PDF

Communities across the United States and particularly in the Midwest continue to grapple with the complications associated with aging infrastructure. This includes the presence of lead (Pb)-bearing plumbing components such as lead service lines, downstream galvanized iron pipes, and Pb/tin solder. The community of Benton Harbor, MI, experienced six Pb action level exceedances between 2018 and 2021, leading to increasing community concern and a request from the state of Michigan for the US Environmental Protection Agency involvement.

View Article and Find Full Text PDF
Article Synopsis
  • * The research found that Cu pipes showed less reactivity to DO and FC than aged DI pipes, especially after brief exposure (2 days) compared to long-term (154-190 days) for DI pipes.
  • * The presence of orthophosphate helped stabilize pH levels at the surface of aged DI pipes, reducing significant fluctuations that otherwise occurred without it.
View Article and Find Full Text PDF

The biological treatment process consisting of an aerated contactor and filter is effective for groundwaters containing elevated ammonia and other reduced contaminants, including iron, manganese, arsenic, and methane. Depth profiles characterizing microbial activity across aerated contactors are lacking. A 1-year pilot study comparing gravel- and ceramic-packed contactors was conducted, and media depth profile samples were collected at the conclusion of the study.

View Article and Find Full Text PDF

Existing heterotrophic denitrification reactors rely on microorganisms to consume dissolved oxygen (DO) and create conditions suitable for denitrification, but this practice leads to excessive microbial growth and increased organic carbon doses. An innovative reactor that uses nitrogen gas sparging through a contactor to strip DO was developed and tested in the lab. It reduced influent nitrate from 15 to <1 mg/L as N with nitrite accumulation <1 mg/L as N.

View Article and Find Full Text PDF

Opportunistic premise plumbing pathogens (OPPPs) have been detected in buildings' plumbing systems causing waterborne disease outbreaks in the United States. In this study, we monitored the occurrence of OPPPs along with free-living amoeba (FLA) and investigated the effects of residential activities in a simulated home plumbing system (HPS). Water samples were collected from various locations in the HPS and analyzed for three major OPPPs: , nontuberculous mycobacterial species (e.

View Article and Find Full Text PDF

Lead service lines (LSLs), when present, are the largest source of lead in drinking water, and their removal is necessary to reduce public exposure to lead from drinking water. Unfortunately, the composition of many service lines (SLs) is uncertain. The town of Bennington, Vermont, for example, has unreliable SL records, making it challenging to build an inventory and conduct an LSL replacement program.

View Article and Find Full Text PDF

Properly certified NSF/ANSI 53 water filters are distributed as a temporary measure to protect residents from risk of exposure to elevated lead (Pb) levels resulting from water system changes and various activities. Water consumers and other stakeholders have raised questions on the performance of these filters in field settings, particularly in cases where water Pb levels exceeded the NSF/ANSI 53 challenge water level of 150 µg/L and when Pb phosphate nanoparticles (≤ 200 nm) were present in drinking water. This literature review summarizes findings from 23 studies that evaluated the ability of NSF/ANSI 53 post-2007 certified filters to reduce soluble and/or particulate Pb from water.

View Article and Find Full Text PDF

Thirty-two short term (∼7.5 h) abiotic experiments were conducted with new ductile iron and copper coupons exposed to various water qualities, including pH (7 or 9), dissolved inorganic carbon (DIC, 10 or 50 mg C L) and phosphate (0 or 3 mg P L) concentrations and 4 mg Cl L free chlorine or monochloramine. To quantify oxidant reactivity with the new metal coupons, microelectrodes were used to obtain oxidant (free chlorine or monochloramine and dissolved oxygen (DO)) concentration and pH microprofiles from the bulk water to near the metal coupon surface.

View Article and Find Full Text PDF

Water lead measurements by two field analyzers, relying on anodic stripping voltammetry (ASV) and fluorescence spectroscopy, were compared to reference laboratory measurements by inductively coupled plasma mass spectrometry (ICP-MS) in progressively complex datasets (phases A, B, C), to assess field analyzer performance. Under controlled laboratory quantitative tests of dissolved lead within the field analysis range and optimal temperature range, lead recoveries by ASV ranged within 85-106 % of reference laboratory values (corresponding linear model: y = 0.96x, r = 0.

View Article and Find Full Text PDF

When implementing anion exchange (AEX) for per- and polyfluoroalkyl substances treatment, temporal drinking water quality changes from concurrent inorganic anion (IA) removal can create unintended consequences (e.g., corrosion control impacts).

View Article and Find Full Text PDF

Aerobic biotreatment systems can treat multiple reduced inorganic contaminants in groundwater, including ammonia (NH), arsenic (As), iron (Fe), and manganese (Mn). While individual systems treating multiple contaminants simultaneously have been characterized and several systems treating one contaminant have been compared, a comparison of systems treating co-occurring contaminants is lacking. This study assessed the treatment performance and microbial communities within 7 pilot- and full-scale groundwater biotreatment systems in the United States that treated waters with pH 5.

View Article and Find Full Text PDF

Background: Exposure to lead (Pb), arsenic (As) and copper (Cu) may cause significant health issues including harmful neurological effects, cancer or organ damage. Determination of human exposure-relevant concentrations of these metal(loids) in drinking water, therefore, is critical.

Objective: We sought to characterize exposure-relevant Pb, As, and Cu concentrations in drinking water collected from homes participating in the American Healthy Homes Survey II, a national survey that monitors the prevalence of Pb and related hazards in United States homes.

View Article and Find Full Text PDF

The study goal was to better understand the risks of elevated copper levels at US schools and childcare centers. Copper health effects, chemistry, occurrence, and remediation actions were reviewed. Of the more than 98,000 schools and 500,000 childcare centers, only 0.

View Article and Find Full Text PDF

With lead service lines (LSLs) remaining for decades to come, scale analyses are critical to helping limit lead exposure from drinking water. This laboratory has used an integrated suite of analytical techniques to characterize the elemental composition, mineral identification, and physical features of scales, helping the water industry to evaluate, predict, and reduce lead corrosion. The methods used in this laboratory to prepare and analyze the LSL scale, and guidance to achieving reliable and meaningful results, are described.

View Article and Find Full Text PDF

Many water systems are challenged with uncertainty regarding service line material type. This work investigated using a simple drinking water flushed sampling approach and a more complicated and invasive sequential profile sampling approach to predict whether homes had an existing lead service line (LSL). Homes that never had an LSL (control groups) and homes with LSLs (study groups) in two communities having different degrees of corrosion control were sampled.

View Article and Find Full Text PDF

A theoretical equilibrium lead(II) (Pb(II)) solubility model coded in Fortran (LEADSOL) was updated and implemented in open source R code, verified against LEADSOL output, and used to simulate theoretical equilibrium total soluble Pb(II) (TOTSOLPb) concentrations under a variety of practical scenarios. The developed R code file (app.R) is publicly available for download at GitHub (https://github.

View Article and Find Full Text PDF

The U.S. Environmental Protection Agency conducted an Arsenic Demonstration Program (ADP) whereby 50 full, small-scale arsenic removal treatment systems were evaluated for removing arsenic to below the maximum contaminant level of 10 μg/L and their operating cost for a minimum of 1 year.

View Article and Find Full Text PDF

Hard water and elevated ammonia are problems for many United States groundwater drinking water utilities, and some utilities, particularly those in the Midwest, face both challenges. Ion (cation) exchange (IX) is a common treatment technique for hardness reduction (i.e.

View Article and Find Full Text PDF

Corrosion of copper material in drinking water systems causes public health concerns and plumbing failures. This study investigated the early corrosion of new copper surfaces using a novel technique: quartz crystal microbalance with dissipation (QCMD). The QCMD results showed that increasing the water pH from 6.

View Article and Find Full Text PDF

Legionella infections have steadily increased in the United States over the last 20 years, and most of these infections have been attributed to contaminated water. The gold standard for confirmation of Legionella presence in water is culturing with Buffered Charcoal Yeast Extract (BCYE) agar. Following many modifications, this method is still time-consuming, expensive, and can take longer than 10 days for full confirmation.

View Article and Find Full Text PDF

Orthophosphate (PO) addition is a common corrosion control treatment used to lower lead (Pb) concentrations at the consumer's tap by forming relatively insoluble Pb-phosphate (Pb-PO) minerals. However, some Pb-PO particles that can form in drinking water are mobile nanoparticles (i.e.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionai4od0f4ssh8oid0orl220rr3sqii56p): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once