Purpose: Directly extracting the respiratory phase pattern of the tumor using cone-beam computed tomography (CBCT) projections is challenging due to the poor tumor visibility caused by the obstruction of multiple anatomic structures on the beam's eye view. Predicting tumor phase information using external surrogate also has intrinsic difficulties as the phase patterns between surrogates and tumors are not necessary to be congruent. In this work, we developed an algorithm to accurately recover the primary oscillation components of tumor motion using the combined information from both CBCT projections and external surrogates.

View Article and Find Full Text PDF

Flattening filter free (FFF) linear accelerators produce a fluence distribution that is forward peaked. Various dosimetric benefits, such as increased dose rate, reduced leakage and out of field dose has led to the growth of FFF technology in the clinic. The literature has suggested the idea of vendors offering dedicated FFF units where the flattening filter (FF) is removed completely and manipulating the beam to deliver conventional flat radiotherapy treatments.

View Article and Find Full Text PDF

Purpose: Traditionally, the treatment couch coordinates (TCCs) for patients undergoing radiotherapy can only be determined at the time of treatment, placing pressure on the treating therapists and leaving several pathways for errors such as wrong-site treatment or wrong treatment table shift from a reference point. The purpose of this work is to propose an accurate, robust, and streamlined system that calculates TCC in advance.

Methods: The proposed system combines the advantages of two different calculation methods that use an indexed immobilization device.

View Article and Find Full Text PDF

Recently, the compressed sensing (CS) based iterative reconstruction method has received attention because of its ability to reconstruct cone beam computed tomography (CBCT) images with good quality using sparsely sampled or noisy projections, thus enabling dose reduction. However, some challenges remain. In particular, there is always a tradeoff between image resolution and noise/streak artifact reduction based on the amount of regularization weighting that is applied uniformly across the CBCT volume.

View Article and Find Full Text PDF

The generalized monitor unit (MU) calculation equation for the Varian enhanced dynamic wedge (EDW) is derived. The assumption of this MU calculation method is that the wedge factor of the EDW at the center of the field is a function of field size, the position of the center of the field in the wedge direction, and the final position of the moving jaw. The wedge factors at the center of the field in both symmetric and asymmetric fields are examined.