Background: A dilated native right ventricular outflow tract (RVOT) presents unique challenges for transcatheter management using balloon-expandable valves. The Alterra Adaptive Prestent was designed to expand transcatheter therapy to treat patients with dilated RVOTs.

Objectives: The aim of this study was to report 2-year outcomes of the main cohort of the ALTERRA (Multicenter Study of Congenital Pulmonic Valve Dysfunction Studying the SAPIEN 3 THV With the Alterra Adaptive Prestent) pivotal trial using the prestent with transcatheter pulmonary valve replacement.

View Article and Find Full Text PDF

Background: Stent implantation has become standard of care in older children and adults for treatment of branch pulmonary artery stenosis (BPAS) and coarctation aorta (CoAo). There are no stents approved or available for infants that have the potential to be dilated to adult diameters. The Minima stent was designed to fulfill this unmet need.

View Article and Find Full Text PDF

Background: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction.

Methods: This is a retrospective, multicenter study of transverse aortic arch stent implantation.

View Article and Find Full Text PDF

Background: Pulmonary hypertension (PH) is a common complication in patients with complete dextro-transposition of the great arteries (TGA) after atrial switch (D-TGA/AS) and congenitally corrected TGA (ccTGA). In this population with subaortic right ventricles (sRVs), echocardiography is a poor screening tool for PH; implantable invasive haemodynamic monitoring (IHM) could be used for this purpose, but data are limited. The aim of this study is to report on novel uses of IHM in patients with sRV.

View Article and Find Full Text PDF

Objective: To describe the current practices in invasive patent ductus arteriosus (PDA) closure (surgical ligation or transcatheter occlusion) in very low birth weight (VLBW) infants and changes in patient characteristics and outcomes from 2016 to 2021 among US children's hospitals.

Study Design: We evaluated a retrospective cohort of VLBW infants (birth weight 400-1499 g and gestational age 22-31 weeks) who had invasive PDA closure within 6 months of age from 2016 to 2021 in children's hospitals in the Pediatric Health Information System. Changes in patient characteristics and outcomes over time were evaluated using generalized linear models and generalized linear mixed models.

View Article and Find Full Text PDF

Objective: This study describes 3-year follow-up of 200 infants weighing ≥ 700 grams who underwent transcatheter patent ductus arteriosus (PDA) closure with the Amplatzer Piccolo™ Occluder.

Study Design: Between June 2017 and February 2019, 200 children were enrolled in this U.S.

View Article and Find Full Text PDF

The aim of the study was to determine the variables associated with high-quality (HQ) versus low-quality (LQ) three-dimensional rotational angiography (3DRA) and create guides for optimization of approach to 3DRA in congenital cardiac catheterization (CCC). CCC has adopted 3DRA as a mainstay, but there has not been systematic analysis of approach to and factors associated with HQ 3DRA. This was a single-center, retrospective study of 3DRAs using Canon Infinix-I platform.

View Article and Find Full Text PDF

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity.

Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models.

Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks.

View Article and Find Full Text PDF

Percutaneous-based patent ductus arteriosus closure is technically feasible among infants less than 1.5 kg. However, marked heterogeneity in the type and nature of adverse events obscures current safety profile assessments.

View Article and Find Full Text PDF

To date, there has been limited investigation of bioabsorbable atrial septal defect (ASD) or patent foramen ovale (PFO) closure devices using clinically relevant large animal models. The purpose of this study is to explore the function and safety of a bioabsorbable ASD occluder (BAO) system for PFO and/or secundum ASD transcatheter closure. Using a sheep model, the intra-atrial septum was evaluated by intracardiac echo (ICE).

View Article and Find Full Text PDF

Background Advancements in the field, including novel procedures and multiple interventions, require an updated approach to accurately assess patient risk. This study aims to modernize patient hemodynamic and procedural risk classification through the creation of risk assessment tools to be used in congenital cardiac catheterization. Methods and Results Data were collected for all cases performed at sites participating in the C3PO (Congenital Cardiac Catheterization Project on Outcomes) multicenter registry.

View Article and Find Full Text PDF

Background: The Melody valve was developed to extend the useful life of previously implanted right ventricular outflow tract (RVOT) conduits or bioprosthetic pulmonary valves, while preserving RV function and reducing the lifetime burden of surgery for patients with complex congenital heart disease.

Methods: Enrollment for the US Investigational Device Exemption study of the Melody valve began in 2007. Extended follow-up was completed in 2020.

View Article and Find Full Text PDF

Transcatheter closure of patent ductus arteriosus (PDA) in premature infants is a feasible, safe, and an effective alternative to surgical ligation and may be performed with an implant success rate of 97%. Major procedural complications related to transcatheter PDA closure in extremely low birth weight (ELBW) infants are relatively infrequent (< 3%) ,but may be associated with a fatality if not optimally managed. Operators performing transcatheter PDA closures should be knowledgeable about these potential complications and management options.

View Article and Find Full Text PDF
Article Synopsis
  • Covered stent correction using the 10-zig Cheatham-platinum (CCP) stent is a new method for treating sinus venosus atrial septal defects (SVASD), with challenges in stent anchoring and expansion without obstructing the pulmonary vein.
  • An international study involving 75 patients revealed that various lengths of CCP stents were used, with additional stents required for anchoring in many cases.
  • Results showed significant improvements after the procedure, with a notable decrease in blood flow ratios, but some patients experienced complications; careful patient selection is crucial for success.
View Article and Find Full Text PDF

Background: Three-dimensional printing is increasingly utilised for congenital heart defect procedural planning. CT or MR datasets are typically used for printing, but similar datasets can be obtained from three-dimensional rotational angiography. We sought to assess the feasibility and accuracy of printing three-dimensional models of CHD from rotational angiography datasets.

View Article and Find Full Text PDF

Background: Stent implantation (SI) is more effective than balloon angioplasty for the treatment of coarctation of the aorta (CoA). Due to technical factors, balloon angioplasty is more commonly performed in small patients. We sought to evaluate outcomes of percutaneous adult sized SI for the treatment of CoA in small patients.

View Article and Find Full Text PDF

Background: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve.

Objectives: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve.

Methods: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve.

View Article and Find Full Text PDF

A fetal echocardiogram noted valvar pulmonary atresia vs critical pulmonary valve stenosis, confluent pulmonary arteries, patent ductus arteriosus, and an apical muscular ventricular septal defect vs coronary sinusoid. Postnatal echocardiogram documented an absent pulmonary valve, coronary artery fistula to the right ventricle, confluent pulmonary arteries, and a patent ductus arteriosus. Catheterization confirmed the postnatal echocardiographic findings except there was no antegrade flow from the right ventricle to the pulmonary arteries.

View Article and Find Full Text PDF

In view of the known complications of drug therapy and open surgical ligation, and the potential for prolonged patent ductus arteriosus (PDA) exposure to be harmful, health care practitioners have sought new approaches to achieve definitive ductal closure. Interest in percutaneous (catheter-based) PDA closure has emerged within the neonatal community as a viable treatment option, because it has been fueled by recent procedural and device modifications, as well as mounting feasibility and safety data. Herein, we provide a contemporary review of percutaneous PDA closure among infants at the crux of the medical debate-very-low-weight infants (≤1,500 g), including: 1) characterization of traditional PDA treatments (drug therapy, open surgical ligation) and conservative (nonintervention) management options; 2) a general overview of the major procedural steps of percutaneous ductal closure, including efforts to reduce thrombotic complications and the emergence of a novel US Food and Drug Administration-approved device; 3) a systematic review and meta-analysis to better understand risk profiles of percutaneous PDA closure in this population; and 4) discussion of current gaps in our understanding of optimal PDA care, including the critical need for well-designed, randomized, controlled clinical trials.

View Article and Find Full Text PDF

Objectives: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure.

Background: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature.

Methods: This was a single arm, prospective, multicenter, non-randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g.

View Article and Find Full Text PDF

We developed a tissue-engineered vascular graft (TEVG) for use in children and present results of a U.S. Food and Drug Administration (FDA)-approved clinical trial evaluating this graft in patients with single-ventricle cardiac anomalies.

View Article and Find Full Text PDF

Objective: We describe the technical considerations of transcatheter implantation of the CardioMEMS™ HF System (Abbott, Abbott Park, IL) in adult patients with complex palliated congenital heart disease (CHD) and advanced heart failure (HF).

Background: Ambulatory pulmonary artery (PA) pressure monitoring with implantable hemodynamic monitors (IHMs) has been shown to reduce HF-related hospital admissions in non-CHD populations. HF is a common late cardiovascular complication in adult CHD necessitating better understanding of IHM application in this population.

View Article and Find Full Text PDF

Step changes in angiographic imaging are not commonplace. Since the move from analogue to digital and flat detector plates, two-dimensional imaging technology has certainly evolved but not jumped forward. Of all the routine imaging techniques used in cardiology, angiography has been the last modality to embrace the third dimension.

View Article and Find Full Text PDF

The Gore Viabahn VBX balloon-expandable endoprosthesis (W. L. Gore & Associates, Flagstaff, AZ) is a flexible covered stent that is FDA-approved for the treatment of iliac artery stenosis, including lesions at the aortic bifurcation.

View Article and Find Full Text PDF