Volatile organic compounds (VOCs) and radon progeny pose potential health risks to occupants of certain buildings via subsurface vapor intrusion (VI) to indoor air. VI mitigation is usually performed using systems that extract gas from below the building, and the system performance is typically evaluated by measuring the distribution of applied vacuum below the floor. This article provides a new approach to assessing the radius of influence (ROI) for subslab venting systems based on mass flux instead of static vacuum distribution and includes an analyses of 121 pneumatic tests performed at 65 different suction points in 16 different buildings.

View Article and Find Full Text PDF

A new method is presented for calculating a building-specific subslab to indoor air attenuation factor for use in assessing subsurface vapor intrusion to indoor air. The technique includes (1) subslab gas extraction with flow and vacuum measurements and mathematical modeling to characterize the bulk average vertical gas conductivity of the floor slab, (2) monitoring of the ambient pressure gradient across the floor slab with a micromanometer, (3) calculating the volumetric flow of soil gas into the building ( Q), and (4) dividing Q by the building ventilation rate ( Q) to calculate a building-specific attenuation factor. Sample calculations using order statistics from 121 individual tests are comparable to the U.