Total hip arthroplasty (THA) is one of the most successful elective operations in orthopedic surgery for improving pain and functional disability in patients with end-stage joint disease. However, dislocation continues to be a troublesome complication after THA, as it is a leading cause of revision and is associated with substantial social, health, and economic costs. It is a relatively rare, usually early occurrence that depends on both the patients' characteristics and the surgical aspects.
View Article and Find Full Text PDFBackground And Aim: Displaced femoral neck fracture (FNF) is a common and significant health issue especially in older population because of the high rates of mortality and complications. The standard surgical treatment is total or partial hip replacement, including a cemented or uncemented stem. The cemented prosthesis is considered the safer option because of a lower rate of periprosthetic fractures (PPFs) as well as an actually reduced risk of bone cement implantation syndrome (BCIS).
View Article and Find Full Text PDFPeriprosthetic joint infection (PJI) is a serious complication following hip arthroplasty, which is associated with significant health cost, morbidity and mortality. There is currently no consensus in the optimal definition of PJI, and establishing diagnosis is challenging because of conflicting guidelines, numerous tests, and limited evidence, with no single test providing a sensitivity and specificity of 100%. Consequently, the diagnosis of PJI is based on a combination of clinical data, laboratory results from peripheral blood and synovial fluid, microbiological culture, histological evaluation of periprosthetic tissue, radiological investigations, and intraoperative findings.
View Article and Find Full Text PDFIntraprosthetic dislocation (IPD) is a specific implant-related complication of dual mobility (DM) implants, which is defined as a dissociation of polyethylene (PE) liner from the femoral head. We report a unique case of late IPD of a monoblock DM cup cemented into a well-fixed cementless acetabular shell for recurrent dislocation of total hip arthroplasty (THA). A 77-year-old woman was admitted to our department for acute right hip pain, functional impairment and inability to bear weight without any trauma.
View Article and Find Full Text PDFFourth generation ceramic bearings (BIOLOX delta, CeramTec AG; Phlochingen, Germany) were developed to reduce wear debris and improve fracture resistance. A case of a fourth generation head fracture in ceramic-on-polyethylene (COP) coupling after hip revision surgery is reported. A 58-year-old man was admitted to our department for increasing hip pain following a direct trauma which occurred during skiing activity 4 months before.
View Article and Find Full Text PDFPatellar tendon rupture after anterior cruciate ligament (ACL) reconstruction is a rare complication which usually occurs in the early postoperative period during rehabilitation. The management of open avulsions from tibial tuberosity has not been clearly defined yet. We describe a previously unreported case of traumatic and open patellar tendon avulsion from tibial tuberosity one year following ACL reconstruction in an elite football player which was successfully treated with suture anchors.
View Article and Find Full Text PDFBackground: Post-traumatic osseous cystic lesions represent a rare complication in children. Usually a post-fracture cyst is a lipid inclusion cyst, which is radiolucent and may be seen adjacent to a healing torus fracture. It is typically asymptomatic and appears just proximal to the fracture line within the area of subperiosteal new bone formation.
View Article and Find Full Text PDFNeck-stem modularity gained recent popularity in hip arthroplasty for clinical advantages, and few complications have been reported. We describe an unusual two-stage failure of the bimodular neck of a cementless forged titanium alloy stem implanted 12 years before. The retrieved neck was forwarded to the manufacturer for metallurgic evaluation and failure analysis.
View Article and Find Full Text PDFPelvic osteolysis induced by particulate debris derived from bearing surfaces is a well-known complication following total hip arthroplasty (THA). Atraumatic fractures of the greater trochanter (GT) associated with osteolytic lesions have been occasionally described. We present a case of a 71-year-old male patient who sustained an undisplaced fracture of the GT nine years following cementless metal-on-polyethylene THA.
View Article and Find Full Text PDFBackground And Aim Of The Work: Surface replacement arthroplasty (SRA) is an alternative to stemmed total hip arthroplasty (THA) providing a femoral bone preserving procedure. Because of the wider surgical dissection, an increased blood loss could be expected. This retrospective study evaluates the transfusion requirement in two homogeneous groups of patients who underwent primary hip replacement electively.
View Article and Find Full Text PDFBackground And Aim Of The Work: Blood loss and transfusion requirements are common in total hip arthroplasty. Tranexamic acid is one of the most interesting options to reduce the need for blood transfusions in a variety of surgical settings. The aim of this study was to assess the efficacy of perioperative intravenous traxexamic acid regarding blood transfusion rate and volume of transfused blood without increasing adverse events after primary elective cementless total hip arthroplasty.
View Article and Find Full Text PDFTransient lateral patellar dislocation (TLPD) is a common lesion in young adults. Vascular injury as a complication of TLPD has not been previously described. We report a case of descending genicular artery (DGA) injury after TLPD.
View Article and Find Full Text PDFBackground And Aim Of The Work: Radiofrequency ablation (RFA) is the gold standard for the treatment of symptomatic osteoid osteoma (OO) as RFA yields both a high success and low complication rate. It has been widely utilized over the years, but recurrences of OO after this treatment have been documented. These recurrences may be the result of various factors, including incomplete tumor ablation, and are significantly higher in lesions greater than 10 mm.
View Article and Find Full Text PDFPipkin fractures are relative rare high-energy lesions characterized by an intra-articular fracture of the femoral head after posterior hip dislocation. Early anatomic reduction and stable fixation are the main goals of treatment. This case evaluates the outcome of managing Pipkin type 2 fracture with acute osteochondral defect of the femoral head using "rotational osteoplasty" and bioabsorbable polylactate pin fixation.
View Article and Find Full Text PDFHair toe tourniquet syndrome (HTTS) is an uncommon pediatric condition occurring when the toe is circumferentially strangulated by human hair or fibers. An 8-week-old little girl was admitted to the Emergency Department because of the worsening swelling in the right second and third toes, which had been been previously treated with a local antibiotic thinking of an infection. An unrecognized HTTS was leading the third toe to necrosis.
View Article and Find Full Text PDFIntroduction. Acute abdominal pain may be the presenting symptom in a wide range of diseases in the elderly. Acute abdominal pain related to a delayed bleeding and pelvic haematoma after a low-energy pubic rami fracture is rare and can have important consequences; to the best of our knowledge, only one case has been previously described.
View Article and Find Full Text PDFReconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC). Twenty-nine patients (32 implants) died for unrelated causes without additional surgery.
View Article and Find Full Text PDFGentamicin (G) and vancomycin (V) concentrations in drainage fluids obtained from patients during the first 24 hours after implantation of antibiotic-loaded polymethylmethacrylate (PMMA) spacers in two-stage revision of infected total hip arthroplasty were studied. The inhibitory activity of drainage fluids against different multiresistant clinical isolates was investigated as well. Seven hips were treated by implantation of industrial G-loaded spacers.
View Article and Find Full Text PDFSurg Technol Int
September 2013
Femoral revision total hip arthroplasty may be a complex procedure due to extensive periprosthetic bone loss. Fluted, tapered stems provide secure axial and rotational stability in the distal femur. We retrospectively evaluated the long-term outcome of the cementless Wagner Self-Locking prosthesis (Sulzer Orthopedics Ltd, Winterthur, Switzerland).
View Article and Find Full Text PDFThe incidence and severity of heterotopic ossification (HO) in two homogeneous groups of patients that received surface replacement arthroplasty (SRA) and conventional total hip arthroplasty (THA) were evaluated retrospectively. Thirty-nine patients undergoing 42 hip resurfacing procedures and 41 primary cementless THAs through an anterolateral approach received a 10-day course of 150 mg/die of indomethacin postoperatively. The median surgical time was 190 minutes and 156 minutes, respectively (P < 0.
View Article and Find Full Text PDF