Treatment of Zenker's diverticulum by flexible endoscopy consists of the myotomy of the cricopharyngeal muscle and is considered to be feasible, effective and safe. This report describes the novel use of a Clutch Cutter® device to perform flexible endoscopic retreatment of a symptomatic recurrence after previous treatment using a Needle knife in a 68 year old woman with symptoms of dysphagia for solids.