Publications by authors named "Daour Yousef El Sarhan"

Article Synopsis
  • The study discusses a technique for using a modified balloon-expandable covered stent to selectively occlude a distal entry tear in a patient with chronic type B aortic dissection and an expanding false lumen.
  • A 63-year-old male patient showed progression in false lumen size, prompting the need for intervention since traditional endovascular repair wasn't an option.
  • The technique involved off-centering the stent to create a funnel shape for effective occlusion, and post-procedure imaging confirmed the successful exclusion of the targeted areas with some residual type 2 endoleak.
View Article and Find Full Text PDF