Cyclic peptides have higher stability and better properties as therapeutic agents than their linear peptide analogues. Consequently, intramolecular click chemistry is becoming an increasingly popular method for the synthesis of cyclic peptides from their isomeric linear peptides. However, assessing the purity of these cyclic peptides by mass spectrometry is a significant challenge, as the linear and cyclic peptides have identical masses.
View Article and Find Full Text PDFEnergy-resolved mass spectrometry (ERMS) and an isotopically labelled internal standard were successfully combined to accurately quantify a tryptic peptide despite the presence of an isobaric interference. For this purpose, electrospray ionisation tandem mass spectrometry (ESI-MS/MS) experiments were conducted into an ion trap instrument using an unconventional 8 m/z broadband isolation window, which encompassed both the tryptic peptide and its internal standard. Interference removal was assessed by determining an excitation voltage that was high enough to maintain a constant value for the analyte/internal standard peaks intensity ratio, thus ensuring accurate quantification even in the presence of isobaric contamination.
View Article and Find Full Text PDFInterferences from isobaric and isomeric compounds represent a common problem in liquid chromatography coupled to mass spectrometry (LC-MS). In this paper, in-source purification and chromatographic separation were combined with the aim of identifying isobaric contamination and quantifying accurately a compound despite the presence of an isobaric co-eluted interference. This is achieved by totally fragmenting in-source the precursor ions of the isobaric interference providing then LC-pseudo-MS capability, which allows an accurate quantification without the need for optimizing the chromatographic conditions to separate the co-eluted interference.
View Article and Find Full Text PDFThe incorporation of lipophilic phosphonodithioesters in phospholipid formulations generates clickable liposomes that react with amines. The kinetics of this metal free phosphonodithioester-amine coupling (PAC) on liposomes in water is reported and can be classified as a fast reaction with a second order rate constant of k ≈ 8 × 102 M-1 s-1. The PAC reaction represents a versatile strategy to functionalize liposomes.
View Article and Find Full Text PDFThe presence of an isobaric contaminant can drastically affect MS and MS/MS patterns leading to erroneous structural and quantitative analysis, which is a real challenge in mass spectrometry. Herein, we demonstrate that MS and MS/MS structural analysis of a compound can be successfully performed despite the presence of an isobaric interference with as low as few millidaltons mass difference by using pseudo-MS . To this end, in-source collisional excitation (in-source CID) and the Survival Yield (SY) technique (energy-resolved collision induced dissociation MS/MS) were performed on two different source geometries: a Z-spray and an orthogonal spray (with a transfer capillary) ionization sources on two different mass spectrometers.
View Article and Find Full Text PDFRecently, it has been shown that energy-resolved mass spectrometry (MS) can provide quantitative information from two isomeric or isobaric compounds in mixtures by using the survival yield (SY) technique together with "gas-phase collisional purification" (GPCP) strategy (Anal. Chem., 2016, 88, p.
View Article and Find Full Text PDFRigorous validation of amino acid sequence is fundamental in the characterization of original and biosimilar protein biopharmaceuticals. Widely accepted workflows are based on bottom-up mass spectrometry, and they often require multiple techniques and significant manual work. Here, we demonstrate that optimization of a set of tandem mass spectroscopy (MS/MS) collision energies and automated combination of all available information in the measurements can increase the sequence validated by one technique close to the inherent limits.
View Article and Find Full Text PDFFunctionality of enzymes is strongly related to water dynamic processes. The control of the redox potential for metallo-enzymes is intimately linked to the mediation of water molecules in the first and second coordination spheres. Here, we report a unique example of supramolecular control of the redox properties of a biomimetic monocopper complex by water molecules.
View Article and Find Full Text PDFModel mixtures of isobaric peptides were studied to evaluate the possibility, using tandem mass spectrometry experiments, for internal standard quantification of a tryptic peptide in the presence of an isobaric interference. To this end, direct injection electrospray ionization-tandem mass spectrometry (ESI-MS/MS) experiments were performed on an ion trap instrument using a large mass-selection window (15 m/ z) encompassing the isobaric mixture and the internal standard; MS/MS experiments were carried out to remove completely the interference from the mixture by fragmenting it. This allowed for the correct intensity assignment for the protonated peptide peak and, thus, for the analyte to be quantified through the relative intensity estimate of this peak with respect to the internal standard.
View Article and Find Full Text PDFIntramolecular click-chemistry is increasingly used to generate and control the architecture of complex macromolecules including peptides. Such compounds are, however, very challenging to analyze, in particular quantitatively and also to assess their purity. In this study, tandem mass spectrometry (MS/MS) experiments were carried out with an ion trap mass spectrometer using the Survival Yield (SY) technique to analyze several mixtures of protonated, alkali and alkaline earth metal complexes of two topological linear and cyclic peptide isomers.
View Article and Find Full Text PDFCollision energy is a key parameter determining the information content of beam-type collision induced dissociation tandem mass spectrometry (MS/MS) spectra, and its optimal choice largely affects successful peptide and protein identification in MS-based proteomics. For an MS/MS spectrum, quality of peptide match based on sequence database search, often characterized in terms of a single score, is a complex function of spectrum characteristics, and its collision energy dependence has remained largely unexplored. We carried out electrospray ionization-quadrupole-time of flight (ESI-Q-TOF)-MS/MS measurements on 2807 peptides from tryptic digests of HeLa and E.
View Article and Find Full Text PDFThe differentiation, characterization, and quantification of isomers and/or isobars in mixtures is a recurrent problem in mass spectrometry and more generally in analytical chemistry. Here we present a new strategy to assess the purity of a compound that is susceptible to be contaminated with another isomeric side-product in trace levels. Providing one of the isomers is available as pure sample, this new strategy allows the detection of isomeric contamination.
View Article and Find Full Text PDF