Publications by authors named "Danuta Sampson"

Article Synopsis
  • Age-related macular degeneration (AMD) is a complex eye disease influenced by both genetic factors and involves a subtype called reticular pseudodrusen (RPD), which increases the risk of severe vision loss.* -
  • A genome-wide association study compared genetic data from individuals with AMD and/or RPD to controls, finding significant associations specifically on chromosome 10, while chromosome 1 did not show this correlation in RPD cases.* -
  • The chromosome 10 region includes a long non-coding RNA related to retinal health, highlighting its potential role in retinal thickness and influencing the outer segment of photoreceptors.*
View Article and Find Full Text PDF

Quantitative assessment of retinal microvasculature in optical coherence tomography angiography (OCTA) images is important for studying, diagnosing, monitoring, and guiding the treatment of ocular and systemic diseases. However, the OCTA user community lacks universal and transparent image analysis tools that can be applied to images from a range of OCTA instruments and provide reliable and consistent microvascular metrics from diverse datasets. We present a retinal extension to the OCTA Vascular Analyser (OCTAVA) that addresses the challenges of providing robust, easy-to-use, and transparent analysis of retinal OCTA images.

View Article and Find Full Text PDF

Optical coherence tomography angiography (OCTA) is a non-invasive, high-resolution imaging modality with growing application in dermatology and microvascular assessment. Accepted reference values for OCTA-derived microvascular parameters in skin do not yet exist but need to be established to drive OCTA into the clinic. In this pilot study, we assess a range of OCTA microvascular metrics at rest and after post-occlusive reactive hyperaemia (PORH) in the hands and feet of 52 healthy people and 11 people with well-controlled type 2 diabetes mellitus (T2DM).

View Article and Find Full Text PDF

Femoral artery (FA) endothelial function is a promising biomarker of lower extremity vascular health for peripheral artery disease (PAD) prevention and treatment; however, the impact of age on FA endothelial function has not been reported in healthy adults. Therefore, we evaluated the reproducibility and acceptability of flow-mediated dilation (FMD) in the FA and brachial artery (BA) (n = 20) and performed cross-sectional FA- and BA-FMD measurements in healthy non-smokers aged 22−76 years (n = 50). FMD protocols demonstrated similar good reproducibility.

View Article and Find Full Text PDF

: diabetes and age are major risk factors for the development of lower extremity peripheral artery disease (PAD). Cocoa flavanol (CF) consumption is associated with lower risk for PAD and improves brachial artery (BA) endothelial function. : to assess if femoral artery (FA) endothelial function and dermal microcirculation are impaired in individuals with type 2 diabetes mellitus (T2DM) and evaluate the acute effect of CF consumption on FA endothelial function.

View Article and Find Full Text PDF

Background: To generate and validate a method to estimate axial length estimated (AL) from spherical equivalent (SE) and corneal curvature [keratometry (K)], and to determine if this AL can replace actual axial length (AL) for correcting transverse magnification error in optical coherence tomography angiography (OCTA) images using the Littmann-Bennett formula.

Methods: Data from 1301 participants of the Raine Study Gen2-20 year follow-up were divided into two datasets to generate (n = 650) and validate (n = 651) a relationship between AL, SE, and K. The developed formula was then applied to a separate dataset of 46 participants with AL, SE, and K measurements and OCTA images to estimate and compare the performance of AL against AL in correcting transverse magnification error in OCTA images when measuring the foveal avascular zone area (FAZA).

View Article and Find Full Text PDF

Purpose: Foveal center marking is a key step in retinal image analysis. We investigated the discordance between the adaptive optics (AO) montage center (AMC) and the foveal pit center (FPC) and its implications for cone mosaic analysis using a commercial flood-illumination AO camera.

Methods: Thirty eyes of 30 individuals (including 15 healthy and 15 patients with rod-cone dystrophy) were included.

View Article and Find Full Text PDF

The visualization and assessment of retinal microvasculature are important in the study, diagnosis, monitoring, and guidance of treatment of ocular and systemic diseases. With the introduction of optical coherence tomography angiography (OCTA), it has become possible to visualize the retinal microvasculature volumetrically and without a contrast agent. Many lab-based and commercial clinical instruments, imaging protocols and data analysis methods and metrics, have been applied, often inconsistently, resulting in a confusing picture that represents a major barrier to progress in applying OCTA to reduce the burden of disease.

View Article and Find Full Text PDF

Purpose: Rod-cone dystrophy (RCD) is characterized by centripetal loss of rod followed by cone photoreceptors. In this prospective, observational cohort, we used flood-illumination adaptive optics (AO) imaging to investigate parafoveal cone loss in regions with preserved ellipsoid zone (EZ) in patients with RCD.

Methods: Eight patients with RCD and 10 age-matched healthy controls underwent spectral-domain optical coherence tomography and AO imaging.

View Article and Find Full Text PDF

Optical coherence tomography angiography (OCTA) performs non-invasive visualization and characterization of microvasculature in research and clinical applications mainly in ophthalmology and dermatology. A wide variety of instruments, imaging protocols, processing methods and metrics have been used to describe the microvasculature, such that comparing different study outcomes is currently not feasible. With the goal of contributing to standardization of OCTA data analysis, we report a user-friendly, open-source toolbox, OCTAVA (OCTA Vascular Analyzer), to automate the pre-processing, segmentation, and quantitative analysis of en face OCTA maximum intensity projection images in a standardized workflow.

View Article and Find Full Text PDF

Adaptive optics flood illumination ophthalmoscopy (AO-FIO) is an established imaging tool in the investigation of retinal diseases. However, the clinical interpretation of AO-FIO images can be challenging due to varied image quality. Therefore, image quality assessment is essential before interpretation.

View Article and Find Full Text PDF

Purpose: Microperimetry measures differential light sensitivity (DLS) at specific retinal locations. The aim of this study is to examine the variation in DLS across the macula and the contribution to this variation of cone distribution metrics and retinal eccentricity.

Methods: Forty healthy eyes of 40 subjects were examined by microperimetry (MAIA) and adaptive optics imaging (rtx1).

View Article and Find Full Text PDF

Purpose: Biallelic crumbs cell polarity complex component 1 (CRB1) mutations can present as Leber congenital amaurosis (LCA), retinitis pigmentosa (RP), or cystic maculopathy. This study reports a novel phenotype of asymptomatic fenestrated slit maculopathy (AFSM) and examines macular volume profile and microperimetry as clinical trial end points in CRB1-associated retinopathies.

Methods: Twelve patients from nine families with CRB1 mutation were recruited.

View Article and Find Full Text PDF

Significance: Pulsatility is a vital characteristic of the cardiovascular system. Characterization of the pulsatility pattern locally in the peripheral microvasculature is currently not readily available and would provide an additional source of information, which may prove important in understanding the pathophysiology of arterial stiffening, vascular ageing, and their linkage with cardiovascular disease development.

Aim: We aim to confirm the suitability of speckle decorrelation optical coherence tomography angiography (OCTA) under various noncontact/contact scanning protocols for the visualization of pulsatility patterns in vessel-free tissue and in the microvasculature of peripheral human skin.

View Article and Find Full Text PDF

Purpose: To determine the impact of an AngioVue software upgrade on total retinal thickness (RT) and inner retinal vessel density (VD) measurements derived from optical coherence tomography angiography (OCTA).

Methods: Optovue OCTA images (3 × 3 mm) from 126 individuals (105 healthy eyes and 72 eyes with retinal disease) were acquired before an upgrade of the AngioVue software, which resulted in an inward shift of the outer boundary of the inner retinal vessels and improved Bruch's membrane segmentation. Total RT and inner retinal VD values were extracted before and after the software upgrade for comparison.

View Article and Find Full Text PDF

We used a new multimodal imaging system that combines optical coherence microscopy and brightfield microscopy. Using this brain monitoring approach and cranial window implantation, we three-dimensionally visualized the vascular network during thrombosis, with high temporal (18 s) and spatial (axial, ; lateral, ) resolution. We used a modified mouse model of photochemical thromboembolic stroke in order to more accurately parallel human stroke.

View Article and Find Full Text PDF

Purpose: To develop a fully automatic method, based on deep learning algorithms, for determining the locations of cone photoreceptors within adaptive optics scanning laser ophthalmoscope images and evaluate its performance against a dataset of manually segmented images.

Methods: A fully convolutional network (FCN) based on U-Net architecture was used to generate prediction probability maps and then used a localization algorithm to reduce the prediction map to a collection of points. The proposed method was trained and tested on two publicly available datasets of different imaging modalities, with Dice overlap, false discovery rate, and true positive reported to assess performance.

View Article and Find Full Text PDF

Importance: All automated image quality indicators for en face optical coherence tomography angiography (OCTA) images require gold standard validation for determining optimum thresholds.

Background: A manual grading system (gold standard) for OCTA images was validated and compared to two automated image quality indicators: signal strength index (SSI) and scan quality index (SQI) generated by different software versions of the Optovue OCTA device.

Design: Retrospective cross-sectional study.

View Article and Find Full Text PDF

Purpose: To determine the influence of choroidal boundary morphology on the accuracy of automated measurements of subfoveal choroidal thickness (SFCT) in swept source optical coherence tomography (SSOCT).

Methods: A retrospective image analysis of foveal-centered horizontal line scans from normal and diseased eyes using the Topcon DRI OCT-1 Atlantis SSOCT was conducted. Subfoveal choroid-scleral junction (CSJ) and retina-choroidal junction (RCJ) morphologies were graded by two observers.

View Article and Find Full Text PDF

Adaptive optics flood illumination ophthalmoscopy (AO-FIO) allows imaging of the cone photoreceptor in the living human retina. However, clinical interpretation of the AO-FIO image remains challenging due to suboptimal quality arising from residual uncorrected wavefront aberrations and rapid eye motion. An objective method of assessing image quality is necessary to determine whether an AO-FIO image is suitable for grading and diagnostic purpose.

View Article and Find Full Text PDF

Purpose: To measure intrasession repeatability and interocular symmetry of the foveal avascular zone area (FAZA) and superficial retinal vessel density (SRVD) using AngioVue Analytics optical coherence tomography angiography (OCTA).

Methods: Fifty healthy individuals were prospectively enrolled. OCTA scans (3 × 3 and 6 × 6 mm) were acquired twice in right and once in left eyes.

View Article and Find Full Text PDF

Purpose: We compared cone density measurements derived from the center of gaze-directed single images with reconstructed wide-field montages using the rtx1 adaptive optics (AO) retinal camera.

Methods: A total of 29 eyes from 29 healthy subjects were imaged with the rtx1 camera. Of 20 overlapping AO images acquired, 12 (at 3.

View Article and Find Full Text PDF

Purpose: To characterize the ultrastructural and functional correlates of hydroxychloroquine (HCQ)-induced subclinical bull's eye lesion seen on near-infrared reflectance (NIR) imaging.

Methods: An asymptomatic 54-year-old male taking HCQ presented with paracentral ring-like scotoma, abnormal multifocal electroretinography (mfERG) and preserved ellipsoid zone on optical coherence tomography (OCT). Dense raster OCT was performed to create en face reflectivity maps of the interdigitation zone.

View Article and Find Full Text PDF

Purpose: To evaluate the impact of image magnification correction on superficial retinal vessel density (SRVD) and foveal avascular zone area (FAZA) measurements using optical coherence tomography angiography (OCTA).

Methods: Participants with healthy retinas were recruited for ocular biometry, refraction, and RTVue XR Avanti OCTA imaging with the 3 × 3-mm protocol. The foveal and parafoveal SRVD and FAZA were quantified with custom software before and after correction for magnification error using the Littman and the modified Bennett formulae.

View Article and Find Full Text PDF

Purpose: To present en face optical coherence tomography (OCT) images generated by graph-search theory algorithm-based custom software and examine correlation with other imaging modalities.

Methods: En face OCT images derived from high density OCT volumetric scans of 3 healthy subjects and 4 patients using a custom algorithm (graph-search theory) and commercial software (Heidelberg Eye Explorer software (Heidelberg Engineering)) were compared and correlated with near infrared reflectance, fundus autofluorescence, adaptive optics flood-illumination ophthalmoscopy (AO-FIO) and microperimetry.

Results: Commercial software was unable to generate accurate en face OCT images in eyes with retinal pigment epithelium (RPE) pathology due to segmentation error at the level of Bruch's membrane (BM).

View Article and Find Full Text PDF