Publications by authors named "Danilo Ricciardi"

We describe the case of a 45-year-old female affected by asthma and nasal polyposis who presented to the emergency department because of worsening dyspnea and paresthesia of the left lower limb. Comprehensive instrumental examinations revealed the presence of severe left ventricle dysfunction, intra-cardiac thrombus, deep vein thrombosis, pulmonary embolism, lung infiltrates, polyserositis, and neurological involvements. Finally, the patient was diagnosed with eosinophilic granulomatosis with polyangiitis (EGPA), formerly Churg-Strauss syndrome, a rare vasculitis of small-medium blood vessels with several organ involvements.

View Article and Find Full Text PDF

Background: There is a paucity of data comparing vitamin K antagonists (VKAs) to direct oral anticoagulants (DOACs) at the time of cardiac implantable electronic device (CIED) surgery. Furthermore, the best management of DOACs (interruption vs continuation) is yet to be determined.

Objectives: This study aimed to compare the incidence of device-related bleeds and thrombotic events based on anticoagulant type (DOAC vs VKA) and regimen (interrupted vs uninterrupted).

View Article and Find Full Text PDF

Background: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of patients with symptomatic atrial fibrillation (AF). AF symptoms are highly subjective; however, they are important outcomes for the patient. The aim is to describe the use and impact of a web-based App to collect AF-related symptoms in a population of patients who underwent PVI-C in seven Italian centers.

View Article and Find Full Text PDF

Cardiac amyloidosis (CA) manifests as infiltrative cardiomyopathy with a hypertrophic pattern, usually presenting with heart failure with a preserved ejection fraction. In addition, degenerative valvular heart disease, particularly severe aortic stenosis, is commonly seen in patients with CA. However, amyloid fibril deposition might also infiltrate the conduction system and promote the development of electrical disorders, including ventricular tachyarrhythmias, atrio-ventricular block or acute electromechanical dissociation.

View Article and Find Full Text PDF

An anomalous aortic origin of a coronary artery (AAOCA) from the opposite sinus, with an interarterial course, has been associated with an increased risk of myocardial ischemia and sudden death. As the exact pathophysiology of AAOCA is not well understood, the clinical management is also not well defined. With increased use of non-invasive imaging, the diagnosis of AAOCA is increasing and the association of anomalous origin and atherosclerotic disease is becoming a more important topic.

View Article and Find Full Text PDF

Background: The absence of pacing capabilities may reduce the appeal of subcutaneous implantable cardioverter-defibrillator (S-ICD) devices for patients at risk for conduction disorders or with antitachycardia pacing (ATP)/cardiac resynchronization (CRT) requirements. Reports of rates of S-ICD to transvenous implantable cardioverter-defibrillator (TV-ICD) system switch in real-world scenarios are limited.

Objective: The purpose of this study was to investigate the need for a subsequent transvenous (TV) device in patients implanted with an S-ICD and its predictors.

View Article and Find Full Text PDF

Background: It has been observed that the fourth-generation cryoballoon (CB4) ablation catheter increased the rate of acute real-time recordings of pulmonary vein isolation (PVI) during the ablation for the treatment of atrial fibrillation (AF). The aim of this analysis was to compare the long-term outcome results between patients treated with the CB4 and second-generation cryoballoon (CB2).

Methods: In total, 492 patients suffering from AF, underwent PVI ablation with either the CB2 or CB4 catheter within this examination of the 1STOP real-world Italian project and were included in the analysis.

View Article and Find Full Text PDF

Background: A few limited case series have shown that the subcutaneous implantable cardioverter-defibrillator (S-ICD) system is safe for teenagers and young adults, but a large-scale analysis currently is lacking.

Objectives: The purpose of this study was to compare mid-term device-associated outcomes in a large real-world cohort of S-ICD patients, stratified by age at implantation.

Methods: Two propensity-matched cohorts of teenagers + young adults (≤30 years old) and adults (>30 years old) were retrieved from the ELISIR Registry.

View Article and Find Full Text PDF

Background: Recently, the Food and Drug Administration issued a recall for the subcutaneous implantable cardioverter-defibrillator (S-ICD) because of the possibility of lead ruptures and accelerated battery depletion.

Objective: The aim of this study was to evaluate device-related complications over time in a large real-world multicenter S-ICD cohort.

Methods: Patients implanted with an S-ICD from January 2015 to June 2020 were enrolled from a 19-institution European registry (Experience from the Long-term Italian S-ICD registry [ELISIR]; ClinicalTrials.

View Article and Find Full Text PDF

Background: To date, only a few comparisons between subcutaneous implantable cardioverter-defibrillator (S-ICD) patients undergoing and those not undergoing defibrillation testing (DT) at implantation (DT+ vs DT-) have been reported.

Objective: The purpose of this study was to compare long-term clinical outcomes of 2 propensity-matched cohorts of DT+ and DT- patients.

Methods: Among consecutive S-ICD patients implanted across 17 centers from January 2015 to October 2020, DT- patients were 1:1 propensity-matched for baseline characteristics with DT+ patients.

View Article and Find Full Text PDF

Background: Current guidelines recommend defibrillation testing (DT) performance in patients with a subcutaneous implantable cardioverter defibrillator (S-ICD), theoretically to reduce the amount of ineffective shocks. DT, however, has been proven unnecessary in transvenous ICD and real-world data show a growing trend in avoidance of DT after S-ICD implantation.

Methods: All patients undergoing S-ICD implant at nine associated Italian centers joining in the ELISIR registry (ClinicalTrials.

View Article and Find Full Text PDF

Background: Multiple left ventricular pacing strategies have been suggested for improving response to cardiac resynchronization therapy (CRT). However, these programming strategies may sometimes entail accepting configurations with high pacing threshold and accelerated battery drain. We assessed the feasibility of predefined pacing programming protocols, and we evaluated their impact on device longevity and their cost-impact.

View Article and Find Full Text PDF

Introduction: Early evidence suggests that multipoint left ventricular pacing (MPP) may improve response to cardiac resynchronization therapy (CRT). It is unknown whether this benefit is sustained and cost-effective. We used real-world data to evaluate long-term impact of MPP-ON clinical status, heart failure hospitalizations (HFH) and costs.

View Article and Find Full Text PDF
Article Synopsis
  • The study reviews the safety and effectiveness of non-vitamin K oral anticoagulants (NOACs) in patients undergoing surgery for cardiac implantable electronic devices (CIEDs).
  • A systematic search included 12 studies with over 2,100 patients, finding low incidences of device-pocket hematomas and thromboembolic events regardless of whether NOACs were continued or interrupted during surgery.
  • Results suggest that while continuing NOACs might lead to slightly more bleeding complications, both continuing and interrupting NOACs are generally safe strategies, though further research is needed to strengthen these conclusions.
View Article and Find Full Text PDF

Background: Twelve-lead ECG represents the most common diagnostic tool in clinical cardiology and allows an immediate screening of left ventricular hypertrophy (LVH), but current criteria might have poor clinical usefulness in everyday clinical practice due to lack of sensitivity.

Methods: The current study aims to review and compare the clinical performance of known ECG criteria of LVH in a real-life setting; 2134 patients had ECG and echocardiographic exams performed during the same hospitalization. All traces were retrospectively analysed, and the amplitudes of the waves were manually measured.

View Article and Find Full Text PDF

Background: Multipoint pacing (MPP) may improve clinical outcomes in patients with cardiac resynchronization therapy defibrillators (CRT-D), but its impact on battery longevity in a real-world population has not been investigated in large trials.

Objective: Compare projected battery longevity in CRT-D patients with and without MPP during long-term follow-up.

Methods: The Italian registry on multipoint left ventricular pacing (IRON-MPP) is a prospective, multicenter registry of patients implanted with MPP-capable CRT-D devices.

View Article and Find Full Text PDF

Purpose: Pulmonary vein isolation (PVI) using cryoablation (PVI-C) is a widespread therapy for treating symptomatic, recurrent atrial fibrillation (AF). The impacts of sex on efficacy and safety of PVI-C in a real-world clinical practice is lacking. In a multicenter prospective project, we evaluated whether clinical characteristics, procedure parameters, procedural complications, long-term AF recurrence rates, and/or AF-related symptoms differed according to sex in patients treated with PVI-C.

View Article and Find Full Text PDF

Atrial fibrillation (AF), is the most common sustained arrhythmia and is associated with a substantial increase in morbidity and mortality. Several studies have demonstrated sex-related differences in various aspects, including age at diagnosis, clinical manifestations, management and prognosis. These dissimilarities may dictate different approaches to management and could translate to differences in outcomes.

View Article and Find Full Text PDF

Data presented in this article are supplementary materials to our article entitled "Catheter Ablation for Fascicular Ventricular Tachycardia: A Systematic review" (Creta et al., 2018). The current article provides additional procedural data regarding the catheter ablation for fascicular ventricular tachycardia (FVT) performed in the patients enrolled in our analysis.

View Article and Find Full Text PDF

Introduction: Catheter ablation has been evaluated as treatment for fascicular ventricular tachycardia (FVT) in several single-centre cohort studies, with variable results regarding efficacy and outcomes.

Methods: A systematic search was performed on PubMed, EMBASE and Cochrane database (from inception to November 2017) that included studies on FVT catheter ablation.

Results: Thirty-eight observational non-controlled case series comprising 953 patients with FVT undergoing catheter ablation were identified.

View Article and Find Full Text PDF

Background: Many patients requiring cardiac implantable electronic device (CIED) implantation are on long-term oral anticoagulant therapy. While continuation of warfarin has been shown to be safe and reduce bleeding complications compared to interruption of warfarin therapy and heparin bridging, it is not known which novel oral anticoagulants (NOAC) regimen (interrupted vs uninterrupted) is better in this setting.

Methods: One-hundred and one patients were randomized to receive CIED implantation with either interrupted or uninterrupted/continuous NOAC therapy before surgery.

View Article and Find Full Text PDF

Background: In 1990 the American Heart Association (AHA) established a standard 0.05 to 150Hz bandwidth for the routine recording of 12-lead electrocardiograms (ECGs). However, subsequent studies have indicated a very high prevalence of deviations from the recommended cutoffs.

View Article and Find Full Text PDF

Background: A proband of Brugada syndrome (BrS) is the first patient diagnosed in a family. There are no data regarding this specific, high-risk population.

Objectives: This study sought to investigate the Brugada probands diagnosed from 1986 through the next 28 years.

View Article and Find Full Text PDF

Aims: This registry was created to describe the experience of 76 Italian centres with a large cohort of recipients of multipoint pacing (MPP) capable cardiac resynchronization therapy (CRT) devices.

Methods And Results: A total of 507 patients in whom these devices had been successfully implanted were enrolled between August 2013 and May 2015. We analysed: (i) current clinical practices for the management of such patients, and (ii) the impact of MPP on heart failure clinical composite response and on the absolute change in ejection fraction (EF) at 6 months.

View Article and Find Full Text PDF