Publications by authors named "Daniela-Micheline Dos Santos"

Background: Compared to high modulus repair materials such as zirconia and alumina, hybrid polymer-ceramic materials have lower stress concentrations in the tooth structure and bonding interface. The aim of this study is to evaluate viable cementation protocols through an integrative review and meta-analysis.

Material And Methods: This systematic review was based on the PRISMA criteria.

View Article and Find Full Text PDF

The objective of this review is to expose the main genetic changes and genetic polymorphisms that may or may not be associated with greater susceptibility to reduced survival of dental implants and, consequently, to their loss. Case-control studies that fully portrayed the specific types of genetic polymorphisms that may be associated with dental implant failure were included by searching in the PubMed, Scopus, and Web of Science databases from 2010 to 2023. The following descriptors and their combinations in English were used to search for articles: "dental implants," "bone genes," "genetics," "polymorphism genetics," "genetic risk factor," and "interleukin.

View Article and Find Full Text PDF

Objective:  The aim of this study was to compare the Morse taper (MT) + titanium base (Ti-Base) abutment with the external hexagon (EH) + Ti-Base abutment by using the strain gauge method in the mesial, distal, and apical-buccal areas around these types of implants.

Materials And Methods:  This study investigated two groups, MT and EH, each comprising five polyurethane samples with a dental implant in the area of artificial tooth 15 (3.75 × 11.

View Article and Find Full Text PDF

The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical external hexagon (EH) and Morse Taper (MT) implants. Forty-four single implants were placed in the edentulous areas of 20 patients who met the inclusion and exclusion criteria. Immediately after implant placement (t1) and after osseointegration (four and six months for mandible and maxilla, respectively) (t2), insertion torque, resonance frequency, and peri-implant bone loss were measured using probing depths and digital periapical radiography.

View Article and Find Full Text PDF

Background: The aim of this systematic review is to determine the effectiveness of self-etching primers in comparison to the conventional protocol with hydrofluoric acid and silane treatment for bonding lithium disilicate ceramics.

Material And Methods: The formulated PICO question for this research was: "Does self-etching silane primer surface treatment in lithium disilicate ceramics present a similar bond strength value compared to conventional hydrofluoric acid and silane treatment?". Combinations of words and appropriate truncations were adapted for each database.

View Article and Find Full Text PDF

Objective: To evaluate the touch perception threshold of the alveolar mucosa and quality of life of edentulous patients before (T0) and 30 days after (T1) the insertion of new complete dentures.

Background: Touch perception is important so that edentulous patients can detect the position of complete dentures in their mouth.

Materials And Methods: This study included 32 complete denture wearers with good oral and systemic health and no temporomandibular disorders for at least 5 years.

View Article and Find Full Text PDF

Objective: The aim was to evaluate the difference in the heat generated between zirconia (Zr) and steel (SS) drills, during implant site preparation.

Material And Methods: This systematic review followed the PRISMA methodology criteria and used the JBI Critical Assessment Guidelines for Quasi-Experimental Studies for quality assessment. The electronic search was conducted by using the PubMed/MEDLINE, Embase, and Cochrane Library databases to January 2023.

View Article and Find Full Text PDF

In this study, we aimed to evaluate the halitosis and pain threshold of the peri-implant soft tissues in individuals rehabilitated with implant-supported prostheses. Forty-eight subjects were divided into four groups (n = 12) according to their prosthetic rehabilitation: single-tooth fixed prosthesis, multi-tooth fixed prosthesis, overdentures, and the Brånemark protocol. Halitosis was measured using a halimeter, whereas the pain threshold was measured using Von Frey monofilaments.

View Article and Find Full Text PDF

The objective of this article is to concisely review the main clinical techniques used to make the functional impression to manufacture a removable partial denture. Through this review, the dentist can develop his clinical knowledge.

View Article and Find Full Text PDF

During the fabrication of a complete denture, functional impression is taken. Literature studies show that polydimethylsiloxane (condensation silicone) has not been reported by United States dental schools to perform border molding. Thus, the purpose of this article is to review the functional impression technique when border molding is performed with a laboratory condensation silicone putty.

View Article and Find Full Text PDF

Background: Ocular prosthesis rehabilitation has an important social, psychological, esthetic, and functional role. Congenital factors, trauma, and tumors, among others, can cause anophthalmia, and it is essential to identify the etiology to guide its prevention and treatment.

Methods: The aim of this study was to retrospectively investigate the records of patients treated from 2013 to 2020 by the Oral and Maxillofacial Prosthesis Group, aiming to identify the prevalence of patients with anophthalmia and the etiology of their anophthalmia.

View Article and Find Full Text PDF

Objectives:  Thus, the aim of this study was to compare the effect of using two preoperative mouthwashes (0.12% chlorhexidine and 0.2% tea tree oil) on the number of colonies of oral microorganisms.

View Article and Find Full Text PDF

Objectives: To determine, through clinical studies, whether there is a correlation between the Periotest value (PTV) and the implant stability quotient (ISQ).

Content: Methods to evaluate the stability of dental implants.

Summary: A search was performed in the PubMed, Scopus, and Web of Science databases for articles on the proposed subject up to January 29, 2023, using search terms that combined "resonance frequency analysis" and "Periotest" with "correlation" or "relationship"; and combinations of "implant stability quotient" and "Periotest" with "correlation" or "relationship.

View Article and Find Full Text PDF

Background: Polymethylmethacrylate (PMMA) is the most used material for the manufacturing of eye prostheses.

Objectives: To investigate the cytotoxicity of different cleaning agents for ocular prostheses on human conjunctival cells.

Material And Methods: Six groups of specimens were created (saline, soap, 4% chlorhexidine, hydrogen peroxide, 1% triclosan, and citronella oil).

View Article and Find Full Text PDF

Background: Occlusal splints can protect teeth during bruxism, preventing tooth wear, as well as during sports activities, shielding them from impacts.

Objectives: To verify the influence of thermal cycles and disinfection on the roughness, microhardness and color of polyethylene terephthalate glycol/thermoplastic polyurethane (PETG/TPU) and poly(methyl methacrylate) (PMMA).

Material And Methods: Thirty-six PETG/TPU samples and 36 PMMA samples were prepared (ø10 mm × 3 mm).

View Article and Find Full Text PDF

Purpose: To assess the reproducibility of four different centric relation (CR) recording techniques, and time spent performing each technique in edentulous individuals.

Materials And Methods: Four techniques were assessed: extraoral gothic arch (EOGA) tracing, intraoral gothic arch (IOGA) tracing, deglutition (D), and frontal manipulation with tongue elevation (FMTE). Twelve subjects participated in the study; four technique records were performed on each volunteer by the same operator.

View Article and Find Full Text PDF

Background: Temporary prosthesis protects the oral tissues, in addition to providing aesthetic look and masticatory function until a definitive prosthesis is manufactured.

Objectives: To evaluate the effect of glaze and 0.12% chlorhexidine (CHX) on the physical and mechanical properties of bis-acryl, and to evaluate the antimicrobial efficacy of CHX.

View Article and Find Full Text PDF

Irritation and biofilm adhesion are complaints associated with ocular prosthesis use. This study aimed to evaluate the effects of prosthesis repolishing on several conditions of anophthalmic volunteers. Participants were divided into two groups: intervention (IG, n = 10) and nonintervention (NIG, n = 6) groups.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of universal adhesives on the long-term bond strength to yttria-stabilized tetragonal zirconia polycrystal (Y-TZP).

Materials And Methods: Polyethylene tubes filled with composite cement containing 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) were adhesively luted to 60 fully sintered Y-TZP slabs (7 x 7 x 2 mm) with or without (control) previous application of a 10-MDP-based adhesive (All Bond Universal, Bisco) - ABU; Clearfil Universal Bond Quick, Kuraray Noritake - CUB; Scotchbond Universal Adhesive, 3M Oral Care - SUA) on the zirconia surface. The bonded specimens were stored in water for 24 h, 6 months, or 1 year and subjected to microshear bond strength testing.

View Article and Find Full Text PDF

An increase in the use of Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) technologies challenges the conventional prosthetic fabrication procedures that are practical and centered on a digital workflow for the patient, especially for dental implants. Increasing workflow of digital restoration work, considering computer-used CAM for restoration technology systems and also fast/CAM for building restoration technology; fast/CAD, also known as abut-Base, has increased interest. Studies on adaptation of different restorative materials, on titanium (Ti)-base abutments, traction, and transformed cycling have become relevant.

View Article and Find Full Text PDF

Objective:  The aim of the study is to evaluate the effect of extrinsic pigmentation on the dimensional stability, hardness, detail reproduction, and color of a silicone after thermocycling.

Materials And Methods:  Sixty samples of MDX4-4210 silicone (Dow Corning Corporation Medical Products) with intrinsic pink pigment (H-109-P, Factor II) and intrinsic opacifier (TiO) were fabricated. Two groups were created: Group 1-only intrinsic pigmentation (H-109P, Factor II + TiO) (Control); and Group 2-intrinsic (H-109P, Factor II + TiO) and extrinsic (Tan FE - 215, Factor II) pigmentation.

View Article and Find Full Text PDF

Background: To verify if there is a correlation of excessive daytime sleepiness (EDS) with bruxism, depression, anxiety, stress, and sex in odontology students.

Material And Methods: Four hundred dental students were selected. Students included in the study were those that were healthy, over 18 years old, and with similar weekly academic activities.

View Article and Find Full Text PDF

The selection of material used on the occlusal surface of implant-supported prostheses is important, as these materials can transmit destructive forces to the interface between the alveolar bone and the implant. Different prosthetic materials are suggested for implant-supported prostheses. The choice of prosthetic material is a controversial issue, and there is a consensus that implant survival is not affected by the prosthetic material.

View Article and Find Full Text PDF

Background: To determine whether there is a correlation of bruxism (sleep, daytime, or both) with oral health-related quality of life and facial pain of muscular origin in dentate individuals.

Material And Methods: Seventy-four dentate patients (complete dentition) were included in this study. These individuals had pain in the facial muscles due to temporomandibular disorder (TMD).

View Article and Find Full Text PDF

Background: To evaluate the stress distribution of three-element prostheses on two different implant systems (External Hexagon (EH) or Morse Taper (MT)) and with two different retention mechanisms (screw-retained or cemented), by photoelastic analysis and strain gauge analyses.

Material And Methods: Four photoelastic and 24 strain gauge models of a partially edentulous maxilla were made and were divided in four groups according to connection and retention system: Group I (EH-C) - external hexagon+cement-retained prosthesis; Group II (EH-S) external hexagon+screw-retained prosthesis; Group III (MT-C) - morse taper+cement-retained prosthesis; Group IV (MT-S) - morse taper+screw-retained prosthesis. The implants were installed in the axial position, the first in the region of element 15 and the distal implant in the region of element 17.

View Article and Find Full Text PDF