Annu Int Conf IEEE Eng Med Biol Soc
July 2023
Emergency mechanical ventilators developed during the pandemic were used to meet the high demand in intensive care units to care for COVID-19 patients. An example of such ventilators is Masi, developed in Peru and installed in more than 15 hospitals around the country. This study aimed to compare Masi's performance with other emergency mechanical ventilators manufactured during the covid-19 pandemic such as Neyün, Spiro Wave and a prototype developed by the Faculty of Engineering of the National University of Asuncion (FIUNA).
View Article and Find Full Text PDFWe introduce an autonomous oxygen concentrator that was designed in Peru to fight the oxygen shortage produced worldwide as a consequence of the COVID-19 pandemic. Oxygen concentrators represent a suitable and favorable option for administering this gas at the patient's bedside in developing countries, especially when cylinders and tubed systems are unavailable or when access to them is restricted by lack of accessories, inadequate power supply, or shortage of qualified personnel. Our system uses a pressure swing adsorption technique to provide oxygen to patients at a flow rate of up to 15 l/min ± 1,5 l/min and a concentration of 93 % ± 3 %, offering robustness, safety and functionality.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2022
The MASI mechanical ventilator was developed in a state of emergency to meet the demand for ventilators caused by COVID-19. Although it has obtained positive results in its use with patients in intensive care units, not having an optimal quality non-invasive ventilation (NIV) modality prevents it from being used in the early treatment of patients, which has been shown to prevent admission to the ICU and reduce mortality. Therefore, the following study focuses on evaluating MASI's ability to provide NIV using different accessories in order to compare their performance and determine which one would work best with MASI, and under which conditions.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
In response to Covid-19 crisis, 310 Masi ventilators were produced and validated in Lima, Peru, according to applicable standards. Four of them, were transported to Puno, in order to strengthen ICU Services there, but this set a major challenge to Masi team as effects of altitude on ventilators were unknown. Once there, ventilators were acclimated and calibrated.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
November 2021
Three hundred and ten rapid-manufactured mechanical ventilators, named Masi, were produced and validated in Peru, according to applicable standards. From these, a sample of 30 was taken and two ventilation parameters, tidal volume and peak inspiratory pressure, were statically analyzed using control charts and histograms. Results show that several points were outside estimated limits for Shewhart means and ranges charts, which could possibly be due to the quantity of equipment used for data recollection and the fact that the Masi team had over 20 engineers.
View Article and Find Full Text PDF