Publications by authors named "Daniel Patel"

Computationally demanding tasks are typically calculated in dedicated data centers, and real-time visualizations also follow this trend. Some rendering tasks, however, require the highest level of confidentiality so that no other party, besides the owner, can read or see the sensitive data. Here we present a direct volume rendering approach that performs volume rendering directly on encrypted volume data by using the homomorphic Paillier encryption algorithm.

View Article and Find Full Text PDF

Endovascular salvage plays an important role in dialysis access care. Angioplasty using standard high- and ultrahigh-pressure balloon is the mainstay of therapy, while the use of cutting balloons and balloons designed to deliver pharmacologically active agents to the site of recurrent stenosis is demonstrating improved performance for specific targets that have to be further defined. Stents and stent grafts are additional tools for use at access segments predisposed for inward remodeling such as the cephalic arch or basilic swing point.

View Article and Find Full Text PDF

Intravascular ultrasound allows for detailed imaging of the dialysis access anatomy. Accurate visualization and precise measurements of the anatomy can be obtained using intravascular ultrasound, while limiting contrast usage and radiation exposure. Intravascular ultrasound allows for a true appreciation of stenosis morphology and can further guide endovascular management decisions, with a particular benefit in management of central venous lesions.

View Article and Find Full Text PDF

The arteriovenous graft (AVG) is one of the major types of permanent vascular access used to provide hemodialysis. Complications encountered with AVG use include stenosis, infection, thrombosis, and pseudoaneurysm formation. Venous outflow stenosis along with frequent needle cannulation at the same site can lead to breakdown of the graft material, resulting in pseudoaneurysm formation.

View Article and Find Full Text PDF

Cardiovascular implantable electronic devices (CIEDs) are frequently utilized for management of cardiac dysrhythmias in patients with chronic kidney disease or end-stage renal disease receiving hemodialysis. The survival benefit from use of implantable cardioverter defibrillators in patients with CKD or ESRD is not as clear as in the general population, particularly when used for primary prevention of sudden cardiac death. Transvenous CIED leads are associated with central vein stenosis resulting in significant adverse consequences for existing or future arteriovenous access.

View Article and Find Full Text PDF

We present a toolbox for quickly interpreting and illustrating 2D slices of seismic volumetric reflection data. Searching for oil and gas involves creating a structural overview of seismic reflection data to identify hydrocarbon reservoirs. We improve the search of seismic structures by precalculating the horizon structures of the seismic data prior to interpretation.

View Article and Find Full Text PDF

This report presents a VR system for evaluation of treatment plans used in radiotherapy (RT), developed to improve the understanding of the spatial relationships between the patient anatomy and the calculated dose distribution. The VR system offers visualization through interactive volume rendering of RT dose distribution and computed tomography (CT) and surface and line rendering of RT structures such as target volumes and organs at risk. The VR system has been installed and networked in a hospital room used for the daily RT conferences, making stereoscopic viewing of treatment planning data for clinical cases possible.

View Article and Find Full Text PDF

Background: The National Kidney Foundation has formulated clinical practice guidelines for patients with chronic kidney disease (K/DOQI). However, little is know about how many patients actually achieve these goals in a dedicated clinic for chronic kidney disease.

Methods: We performed a cross-sectional analysis of 198 patients with an estimated glomerular filtration rate of less than 30 ml/min/1.

View Article and Find Full Text PDF